Mechanical analysis of the improved superelastic Ni-Ti alloy wire using the orthodontic simulator with high-precision sensors

被引:2
|
作者
Mikami, Naoaki [1 ]
Yonemitsu, Ikuo [1 ]
Takemura, Hiroshi [2 ]
Kondou, Mark [2 ]
Soga, Kouhei [3 ]
Suga, Kazuhiro [4 ]
Kanno, Zuisei [1 ]
Lai, WeiJen [1 ,5 ]
Uo, Motohiro [6 ]
Ono, Takashi [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Orthodont Sci, 1-5-45 Yushima,Bunkyo Ku, Tokyo 1138510, Japan
[2] Tokyo Univ Sci, Fac Sci & Engn, Dept Mech Engn, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[3] Tokyo Univ Sci, Fac Adv Engn, Dept Mat Sci & Technol, 6-3-1 Niijuku,Katsushika Ku, Tokyo 1258585, Japan
[4] Kogakuin Univ, Fac Engn, Dept Mech Engn, 1-24-2 Nishi Shinjuku,Shinjuku Ku, Tokyo 1638677, Japan
[5] Natl Taiwan Univ, Sch Dent, Dept Dent, 1 Chang Te St, Taipei City 10048, Taiwan
[6] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Adv Biomat, 1-5-45 Yushima,Bunkyo Ku, Tokyo 1138510, Japan
基金
日本学术振兴会;
关键词
Orthodontics; Orthodontic measurement system; 6-Axis sensor; Treatment mechanics; FORCE SYSTEM; V-BENDS;
D O I
10.1016/j.jmbbm.2023.105861
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The authors have been using improved superelastic Nickel-Titanium alloy wire (ISW) to close and align extraction spaces simultaneously, instead of separately using rigid wires for closing extraction spaces and Ni-Ti alloy wires for leveling and aligning. ISW has a low stiffness, which makes it challenging to generate sufficient moments. This study aimed to demonstrate the forces and moments exerted on adjacent brackets using an or-thodontic simulator (OSIM) attached to a high-precision 6-axis sensor. Materials and methods: In experiment 1, a 0.016 x 0.022-inch ISW, stainless steel (SS) wire, and beta-titanium wires were ligatured into the two brackets. The 0.018 x 0.025-inch slot self-ligating brackets were bonded to two simulated teeth at the same height, and the experiment was conducted using the high-precision OSIM. The distance between the brackets was 10 mm, the V-bend angles of the installed wires were 10 degrees, 20 degrees, 30 degrees, and 40 degrees, and the apex position was set at the center of the bracket. In experiment 2, 6.0-and 9.0-mm long elastomeric chains were placed on the same brackets as in Experiment 1 to measure forces and moments. The distance be-tween the brackets was increased by 1.0 mm from 6.0 to 15.0 mm. Both experiments were conducted in a 37 degrees C thermostatic chamber similar to the oral environment. Results and discussion: In experiment 1, we measured moments on both sides for all the wires. As the V-bend angle increased, the absolute values of the moments also increased. With a V-bend angle of 10 degrees, there was a significant (p < 0.05) difference in the moment generated in the left and right brackets among the three wire types. In the ISW,-1.67 +/- 0.38 N center dot mm was generated in the left bracket, while 0.38 +/- 0.26 N center dot mm was generated in the right bracket at 10 degrees. At 20 degrees,-1.77 +/- 0.69 N center dot mm was generated in the left bracket, while 2.37 +/- 0.94 N center dot mm was generated in the right bracket. At 30 degrees,-2.98 +/- 0.49 N center dot mm was generated in the left bracket, while 3.25 +/- 0.32 N center dot mm was generated in the right bracket. Moreover, at 40 degrees,-3.96 +/- 0.58 N center dot mm was generated in the left bracket, while 3.55 +/- 0.53 N center dot mm was generated in the right bracket. Furthermore, in experiment 2, the moments increased in proportion to the increase in distance between the centers of the two brackets. Absolute values of the moments were approximately equal for the left and right brackets. The 6.0-mm elastomeric chain generated a minimum force of-0.09 +/- 0.05 N in the left direction when the distance between brackets was 6.0 mm, while a maximum of 1.24 +/- 0.3 N when the distance between brackets was 12 mm in the right bracket. In the left bracket, minimum and maximum forces of-0.09 +/- 0.07 and 1.3 +/- 0.4 N were generated in the right direction, respectively. The 9.0-mm elastomeric chain generated a minimum force of 0.03 +/- 0.07 N in the left direction when the distance between brackets was 9.0 mm, while a maximum of 1.3 +/- 0.1 N when the distance between brackets was 15 mm in the right bracket. In the left bracket, minimum and maximum forces of 0.05 +/- 0.06 and 0.98 +/- 0.2 N were generated in the right direction, respectively. Conclusion: Mechanical data of the ISW have been collected in the study, which was previously difficult to perform owing to the low stiffness of the wire. It is suggested that the ISW can provide sufficient moments with the addition of V-bends to close the space by bodily movement.
引用
收藏
页数:6
相关论文
共 48 条
  • [21] Autonomous State Estimation and Observability Analysis for the Taiji Formation Using High-Precision Optical Sensors
    Wen, Bo
    Tang, Wenlin
    Peng, Xiaodong
    Yang, Zhen
    SENSORS, 2023, 23 (21)
  • [22] Mechanical analysis of super-elasticity with stress-hysteresis: Finite element modelling of Ti-Ni orthodontic wire
    Ishida, T
    Hisano, M
    Otsubo, K
    Soma, K
    Knox, J
    Hubsch, P
    Jones, ML
    Middleton, J
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 611 - 616
  • [23] High-Precision Analysis of J-C Dynamic Constitutive Parameters of Ti Alloy and Its Ballistic Performance
    Hao Fang
    Zhao Pingluo
    Mao Youchuan
    Zhang Fan
    Cheng Haisheng
    Du Yuxuan
    Wang Kaixuan
    Liu Xianghong
    Feng Yong
    RARE METAL MATERIALS AND ENGINEERING, 2021, 50 (12) : 4348 - 4356
  • [24] High-Precision Analysis of J-C Dynamic Constitutive Parameters of Ti Alloy and Its Ballistic Performance
    钛合金J-C动态本构参数高精度分析及抗弹性能研究
    Du, Yuxuan (eason@c-wst.com), 1600, Science Press (50): : 4348 - 4356
  • [25] Dependence of aging parameters on precipitation behavior, martensitic transformation and mechanical properties of the aged Ni-Ti alloy under super high pressure
    Yi, Xiaoyang
    Gao, Weihong
    Wang, Haizhen
    Yao, Wen
    Meng, Xianglong
    Gao, Zhiyong
    Cai, Wei
    Zhao, Liancheng
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 736 : 354 - 363
  • [26] DSC and microstructure analysis of high temperature Ni-Ti-Hf, low hysteresis Ni-Ti-Cu and conventional super-elastic and shape memory Ni-Ti alloy ingots and wires
    Lemke, J. N.
    Coda, A.
    MATERIALS TODAY COMMUNICATIONS, 2019, 21
  • [27] A study on the influence of Ni-Ti M-Wire in the flexural fatigue life of endodontic rotary files by using Finite Element Analysis
    Montalvao, Diogo
    Qiu Shengwen
    Freitas, Manuel
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 : 172 - 179
  • [28] Depth distribution analysis of alloying and impurity elements in Ni-Ti alloy thin films using secondary ion mass spectrometer
    Karki, Vijay
    Das, Avik
    Sanyal, Kaushik
    Bhattacharya, Debarati
    THIN SOLID FILMS, 2023, 773
  • [29] High-precision and high-speed etching of diamond surfaces using Fe-Ni alloy catalyzed H-O plasma etching
    Wen, Dongyue
    Li, Yicun
    Zhao, Jiwen
    Hao, Xiaobin
    Zhang, Sen
    Liu, Benjian
    Zhang, Yumin
    Ralchenko, Viktor
    Dai, Bing
    Zhu, Jiaqi
    CARBON, 2024, 218
  • [30] Mechanical Behaviour of Umbrella-Shaped, Ni-Ti Memory Alloy Femoral Head Support Device during Implant Operation: A Finite Element Analysis Study
    Yi, Wei
    Tian, Qing
    Dai, Zhipeng
    Liu, Xiaohu
    PLOS ONE, 2014, 9 (06):