Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates

被引:2
|
作者
Stehle, Thomas [1 ,2 ,3 ]
Wei, Felix [1 ,4 ]
Brabant, Severine [9 ]
Luciani, Alain [1 ,4 ]
Grimbert, Philippe [2 ,3 ]
Prie, Dominique [9 ,10 ]
Reizine, Edouard [1 ,4 ]
Durrbach, Antoine [2 ,3 ,11 ,12 ]
Mule, Sebastien [1 ,4 ]
Hulin, Anne [1 ,5 ]
Boueilh, Anna [1 ,2 ,3 ]
Blain, Maxime [1 ,2 ,4 ]
Champy, Cecile-Maud [1 ,6 ]
Ingels, Alexandre [1 ,6 ]
Matignon, Marie [1 ,3 ]
Brasseur, Paul [1 ,7 ,8 ]
Canoui-Poitrine, Florence [1 ,7 ,8 ]
Pigneur, Frederic [1 ,4 ]
机构
[1] Univ Paris Est Creteil, Inst Natl Sante & Rech Med INSERM U955, Inst Mondor Rech Biomed, Creteil, France
[2] Hop Univ Henri Mondor, AP HP, Serv Nephrol & Transplantat, Creteil, France
[3] Hop Univ Henri Mondor, AP HP, Federat Hosp Univ Innovat Therapy Immune Disorders, Creteil, France
[4] Hop Univ Henri Mondor, AP HP, Serv Imagerie Med, Creteil, France
[5] Hop Univ Henri Mondor, AP HP, Lab Pharmacol, Creteil, France
[6] Hop Univ Henri Mondor, AP HP, Serv Urol, Creteil, France
[7] Hop Univ Henri Mondor, AP HP, Serv Sante Publ, Creteil, France
[8] Hop Univ Henri Mondor, AP HP, Unite Rech Clin, Creteil, France
[9] Grp Hosp Necker Enfants Malad, AP HP, Serv Physiol & Explorat Fonct, Paris, France
[10] Univ Paris Cite, Fac Med, INSERM U1151, Paris, France
[11] Univ Paris Saclay, Fac Med, Orsay, France
[12] Inst Gustave Roussy, INSERM, UMR 1186, Villejuif, France
关键词
CREATININE CLEARANCE; SERUM CREATININE; PLASMA SAMPLE; GATES METHOD; EQUATION; PHARMACOKINETICS; VALIDATION; GFR;
D O I
10.1148/radiol.230567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Estimating glomerular filtration rate (GFR) from serum creatinine can be inaccurate, and current procedures for measuring GFR are time-consuming and cumbersome. Purpose: To develop a method for measuring GFR based on iomeprol clearance assessed at CT urography in kidney donor candidates and compare this with iohexol clearance (reference standard for measuring GFR). Materials and Methods: This cross-sectional retrospective study included data from kidney donor candidates who underwent both iohexol clearance and CT urography between July 2016 and October 2022. CT -measured GFR was calculated as the iomeprol excretion rate in the urinary system between arterial and excretory phases (Hounsfield units times milliliters per minute) divided by a surrogate for serum iomeprol concentration in the aorta at the midpoint (in Hounsfield units). Performance of CT -measured GFR was assessed with use of mean bias (mean difference between CT -measured GFR and iohexol clearance), precision (the distance between quartile 1 and quartile 3 of the bias [quartile 3 minus quartile 1], with a small value indicating high precision), and accuracy (percentage of CT -measured GFR values falling within 10%, 20%, and 30% of iohexol clearance values). Intraobserver agreement was assessed for 30 randomly selected individuals with the Lin concordance correlation coefficient. Results: A total of 75 kidney donor candidates were included (mean age, 51 years +/- 13 [SD]; 45 female). The CT -measured GFR was unbiased (1.1 mL/min/1.73 m2 [95% CI: -1.9, 4.1]) and highly precise (16.2 mL/min/1.73 m2 [quartiles 1 to 3, -6.6 to 9.6]). The accuracy of CT -measured GFR within 10%, 20%, and 30% was 61.3% (95% CI: 50.3, 72.4), 88.0% (95% CI: 80.7, 95.4), and 100%, respectively. Concordance between CT -based GFR measurements taken 2 months apart was almost perfect (correlation coefficient, 0.99 [95% CI: 0.98, 0.99]). Conclusion: In living kidney donors, GFR measured based on iomeprol clearance assessed at CT urography showed good agreement with GFR measured based on iohexol clearance. (c) RSNA, 2023
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Impact of the New Glomerular Filtration Rate Formulas on Kidney Function Assessment in Living Kidney Donors and Candidates
    Al Jurdi, Ayman
    Safa, Kassem
    TRANSPLANTATION DIRECT, 2023, 9 (04):
  • [22] Kidney temperature during living donor kidney transplantation is associated with short-term measured glomerular filtration rate - a prospective study
    Benjamens, Stan
    van den Berg, Tamar A. J.
    Kuipers, Thomas G. J.
    Moers, Cyril
    Berger, Stefan P.
    Leuvenink, Henri G. D.
    Pol, Robert A.
    TRANSPLANT INTERNATIONAL, 2020, 33 (02) : 174 - 180
  • [23] Utility of the Japanese Glomerular Filtration Rate Equation in Estimating Glomerular Filtration Rate of Donor Kidney
    Tsujimura, K.
    Shirakawa, H.
    Tokumoto, T.
    Endou, M.
    Wakai, S.
    Ishida, H.
    Tanabe, K.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (03) : 734 - 737
  • [24] Early Decline of Glomerular Filtration Rate After Liver Transplantation Assessed With a Measured Clearance Technique.
    Penninga, L.
    Hornum, M.
    Hillingso, J.
    Plagborg, U.
    Oturai, P.
    Feldt-Rasmussen, B.
    Rasmussen, A.
    TRANSPLANTATION, 2014, 98 : 757 - 758
  • [25] Early Decline of Glomerular Filtration Rate After Liver Transplantation Assessed With a Measured Clearance Technique.
    Penninga, L.
    Hornum, M.
    Hillingso, J.
    Plagborg, U.
    Oturai, P.
    Feldt-Rasmussen, B.
    Rasmussen, A.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 : 757 - 758
  • [26] Assessment of Glomerular Filtration Rate and End-Stage Kidney Disease Risk in Living Kidney Donor Candidates: A Paradigm for Evaluation, Selection, and Counseling
    Inker, Lesley A.
    Koraishy, Farrukh M.
    Goyal, Nitender
    Lentine, Krista L.
    ADVANCES IN CHRONIC KIDNEY DISEASE, 2018, 25 (01) : 21 - 30
  • [27] Osteoporosis Treatment and Chronic Kidney Disease as Measured by Creatinine Clearance and Estimated Glomerular Filtration Rate
    Decker, Brian
    Liu, Ziyue
    Nguyen, Allison Martin
    Rosenman, Marc
    Martin, Joel
    Allen, Katie
    Hui, Siu Lui
    Imel, Erik
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S199 - S199
  • [28] DYNAMIC OF MEASURED GLOMERULAR FILTRATION RATE (MGFR) IN LIVING KIDNEY DONORS BEFORE AND AFTER KIDNEY DONATION
    Artinger, Katharina
    Knizacek, Claudia
    Hessl, Andrea
    Meinitzer, Andreas
    Zigeuner, Richard
    Mueller, Helmut
    Mauric, Astrid
    Filipic, Karin
    Schemmer, Peter
    Rosenkranz, Alexander R.
    Zitta, Sabine
    TRANSPLANT INTERNATIONAL, 2017, 30 : 307 - 307
  • [29] Scaling of Measured Glomerular Filtration Rate in Kidney Donor Candidates by Anthropometric Estimates of Body Surface Area, Body Water, Metabolic Rate, or Liver Size
    Daugirdas, John T.
    Meyer, Kathryn
    Greene, Tom
    Butler, Robert S.
    Poggio, Emilio D.
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (10): : 1575 - 1583
  • [30] Evaluation of glomerular filtration rate in living kidney donors
    Artigas, C.
    Estorch, M.
    Facundo, C.
    Cerecedo, M.
    Flotats, A.
    Camacho, V.
    Duch, J.
    Fernandez, A.
    Salip, A.
    Gich, I.
    Carrio, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S254 - S254