T1 maps in upper abdomen: comparison of Look-Locker and B1-corrected variable-flip-angle (VFA) methods

被引:1
|
作者
Wang, Zhaoqi [1 ]
Chu, Funing [1 ]
Bai, Bingmei [1 ]
Han, Shuai [1 ]
Zhang, Hongkai [1 ]
Yan, Xu [2 ]
Zhang, Shouning [1 ]
Dong, Yafeng [1 ]
Jiang, Lina [1 ]
Zhao, Yan [1 ]
Kamel, Ihab R. R. [3 ]
Li, Hailiang [1 ]
Qu, Jinrong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Siemens Ltd, NEA MR Collaborat, Shanghai 201318, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; MR relaxometry; T1; mapping; Liver; Look-locker; B1-corrected VFA; CONTRAST-ENHANCED MRI; MAGNETIC-RESONANCE; CHRONIC HEPATITIS; LIVER-CIRRHOSIS; DIAGNOSIS; ULTRASOUND; ACCURACY;
D O I
10.1007/s42058-022-00114-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeT1 mapping has been recognized as a promising tool for quantitative measurements of various tissues that may assist in accurate and tissue specific diagnosis. The purpose of this study was to compare the T1 values of two whole-liver T1 mapping methods, free-breathing Look-Locker and breath-hold B1-corrected variable-flip-angle (VFA) in diagnosing liver cirrhosis, and compare the T1 relaxation time of various upper abdominal organs using two methods.MethodsNon-enhanced T1 mapping with whole-liver coverage was performed on 85 prospectively enrolled suspicious liver tumor patients. Multiple abdominal MRI sequences were obtained. Image quality was assessed by scoring image artifacts on 5-point scale. T1 relaxation time for each organ was recorded. Statistical significance analyzed using Paired t test.ResultsT1 maps of Look-Locker method showed fewer artifacts, with score 5 in all cases compared to 36% in VFA method. There was no significant difference between cirrhotic and non-cirrhotic livers of either left or right lobe in both methods. T1 relaxation time was significantly lower (p < 0.0001) in Look-Locker than VFA method in both lobes of liver, spleen, pancreas, left kidney, right kidney, kidney cortex and medulla, erector spinae and rectus abdominis. No significant difference was found between left and right lobe of liver in both methods. T1 relaxation time of both methods was significantly lower in kidney cortex (p < 0.0001) than medulla on both left and right kidneys.ConclusionsThe choice of Look-Locker or B1-corrected VFA-based T1 mapping may affect T1 values of organs in upper abdomen. Look-Locker showed better image quality and less motion artifacts than B1-corrected VFA method.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 48 条
  • [31] Liver Biliary Function Evaluation on a 1.5T Magnetic Resonance Imaging Scan by T1 Reduction Rate Assessment Using Variable-Flip-Angle Sequences
    Di Stasio, Marco
    Cordopatri, Cesare
    Nardi, Cosimo
    Busoni, Simone
    Noferini, Linhsia
    Colagrande, Stefano
    Calistri, Linda
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (03) : 354 - 360
  • [32] Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements
    Hurley, Samuel A.
    Yarnykh, Vasily L.
    Johnson, Kevin M.
    Field, Aaron S.
    Alexander, Andrew L.
    Samsonov, Alexey A.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 54 - 64
  • [33] Analysis of the Precision of Variable Flip Angle T1 Mapping with Emphasis on the Noise Propagated from RF Transmit Field Maps
    Lee, Yoojin
    Callaghan, Martina F.
    Nagy, Zoltan
    FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [34] Dual flip-angle IR-FLASH with spin history mapping for B1+corrected T1 mapping: Application to T1 cardiovascular magnetic resonance multitasking
    Serry, Fardad Michael
    Ma, Sen
    Mao, Xianglun
    Han, Fei
    Xie, Yibin
    Han, Hui
    Li, Debiao
    Christodoulou, Anthony G.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3182 - 3191
  • [35] Validation of single reference variable flip angle (SR-VFA) dynamic T1 mapping with T2* correction using a novel rotating phantom
    Malmberg, Michael A.
    Odeen, Henrik
    Hofstetter, Lorne W.
    Hadley, J. Rock
    Parker, Dennis L.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (04) : 1419 - 1433
  • [36] Look-Locker和B1修正变量翻转角技术在正常乳腺组织T1值测量中的对照研究
    蒋辉
    曲金荣
    邵楠楠
    李祥
    孟帆
    张宏凯
    黎海亮
    放射学实践, 2019, 34 (01) : 26 - 29
  • [37] Infarct myocardium tissue heterogeneity assessment using pre-contrast and post-contrast T1 maps acquired with Modified Look-Locker Inversion Recovery (MOLLI) imaging
    Zhong Chen
    Tobias Voigt
    Andrea Wiethoff
    Siobhan Crichton
    David Murday
    Anoop Shetty
    Aldo Rinaldi
    Eike Nagel
    Valentina O Puntmann
    Tobias Schaeffter
    Reza Razavi
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [38] Effects of B1 inhomogeneity correction for three-dimensional variable flip angle T1 measurements in hip dGEMRIC at 3 T and 1.5 T
    Siversson, Carl
    Chan, Jenny
    Tiderius, Carl-Johan
    Mamisch, Tallal Charles
    Jellus, Vladimir
    Svensson, Jonas
    Kim, Young-Jo
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1776 - 1781
  • [39] Small Animal Look-Locker Inversion Recovery (SALLI) for Simultaneous Generation of Cardiac T1 Maps and Cine and Inversion Recovery-prepared Images at High Heart Rates: Initial Experience
    Messroghli, Daniel R.
    Nordmeyer, Sarah
    Buehrer, Martin
    Kozerke, Sebastian
    Dietrich, Thore
    Kaschina, Elena
    Becher, Peter M.
    Hucko, Thomas
    Berger, Felix
    Klein, Christoph
    Kuehne, Titus
    RADIOLOGY, 2011, 261 (01) : 258 - 265
  • [40] Comparison of DCE-MRI parametric mapping using MP2RAGE and variable flip angle T1 mapping
    Bergen, Robert V.
    Ryner, Lawrence
    Essig, Marco
    MAGNETIC RESONANCE IMAGING, 2023, 95 : 103 - 109