T1 maps in upper abdomen: comparison of Look-Locker and B1-corrected variable-flip-angle (VFA) methods

被引:1
|
作者
Wang, Zhaoqi [1 ]
Chu, Funing [1 ]
Bai, Bingmei [1 ]
Han, Shuai [1 ]
Zhang, Hongkai [1 ]
Yan, Xu [2 ]
Zhang, Shouning [1 ]
Dong, Yafeng [1 ]
Jiang, Lina [1 ]
Zhao, Yan [1 ]
Kamel, Ihab R. R. [3 ]
Li, Hailiang [1 ]
Qu, Jinrong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Siemens Ltd, NEA MR Collaborat, Shanghai 201318, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; MR relaxometry; T1; mapping; Liver; Look-locker; B1-corrected VFA; CONTRAST-ENHANCED MRI; MAGNETIC-RESONANCE; CHRONIC HEPATITIS; LIVER-CIRRHOSIS; DIAGNOSIS; ULTRASOUND; ACCURACY;
D O I
10.1007/s42058-022-00114-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeT1 mapping has been recognized as a promising tool for quantitative measurements of various tissues that may assist in accurate and tissue specific diagnosis. The purpose of this study was to compare the T1 values of two whole-liver T1 mapping methods, free-breathing Look-Locker and breath-hold B1-corrected variable-flip-angle (VFA) in diagnosing liver cirrhosis, and compare the T1 relaxation time of various upper abdominal organs using two methods.MethodsNon-enhanced T1 mapping with whole-liver coverage was performed on 85 prospectively enrolled suspicious liver tumor patients. Multiple abdominal MRI sequences were obtained. Image quality was assessed by scoring image artifacts on 5-point scale. T1 relaxation time for each organ was recorded. Statistical significance analyzed using Paired t test.ResultsT1 maps of Look-Locker method showed fewer artifacts, with score 5 in all cases compared to 36% in VFA method. There was no significant difference between cirrhotic and non-cirrhotic livers of either left or right lobe in both methods. T1 relaxation time was significantly lower (p < 0.0001) in Look-Locker than VFA method in both lobes of liver, spleen, pancreas, left kidney, right kidney, kidney cortex and medulla, erector spinae and rectus abdominis. No significant difference was found between left and right lobe of liver in both methods. T1 relaxation time of both methods was significantly lower in kidney cortex (p < 0.0001) than medulla on both left and right kidneys.ConclusionsThe choice of Look-Locker or B1-corrected VFA-based T1 mapping may affect T1 values of organs in upper abdomen. Look-Locker showed better image quality and less motion artifacts than B1-corrected VFA method.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 48 条
  • [21] Accelerated 3D metabolite T1 mapping of the brain using variable-flip-angle SPICE
    Zhao, Yibo
    Li, Yudu
    Guo, Rong
    Jin, Wen
    Sutton, Brad
    Ma, Chao
    El Fakhri, Georges
    Li, Yao
    Luo, Jie
    Liang, Zhi-Pei
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1310 - 1322
  • [22] Optimization and Evaluation of Reference Region Variable Flip Angle (RR-VFA) B1+ and T1 Mapping in the Prostate at 3T
    Rangwala, Novena A.
    Dregely, Isabel
    Wu, Holden H.
    Sung, Kyunghyun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 751 - 760
  • [23] Flip angle profile correction for T1 and T2 quantification with look-locker inversion recovery 2D steady-state free precession imaging
    Cooper, Mitchell A.
    Nguyen, Thanh D.
    Spincemaille, Pascal
    Prince, Martin R.
    Weinsaft, Jonathan W.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1579 - 1585
  • [24] Influence of Fat on Liver T1 Measurements Using Modified Look-Locker Inversion Recovery (MOLLI) Methods at 3T
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Pavlides, Michael
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 105 - 111
  • [25] Free-breathing self-gated continuous-IR spiral T1 mapping: Comparison of dual flip-angle and Bloch-Siegert B1-corrected techniques
    Zhou, Ruixi
    Wang, Junyu
    Weller, Daniel S.
    Yang, Yang
    Mugler, John P., III
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1068 - 1080
  • [26] Local Flip Angle Correction for Improved Volume T1-Quantification in Three-Dimensional dGEMRIC Using the Look-Locker Technique
    Siversson, Carl
    Tiderius, Carl-Johan
    Dahlberg, Leif
    Svensson, Jonas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) : 834 - 841
  • [27] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [28] Simultaneous T1 and B1+ Mapping Using Reference Region Variable Flip Angle Imaging
    Sung, Kyunghyun
    Saranathan, Manojkumar
    Daniel, Bruce L.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 954 - 961
  • [29] Myocardial T1 measurement: comparison of modified Look-Locker inversion recovery (MOLLI) and TI scout in the Multi-ethnic Study of Atherosclerosis (MESA)
    Yuan Chang Liu
    Chia-Ying Liu
    Rob J van der Geest
    Songtao Liu
    Marcelo Nacif
    Joao A Lima
    David A Bluemke
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [30] Shortened modified look-locker inversion recovery for myocardial T1 mapping in healthy volunteers: determination of reference T1 relaxation times at 3 Tesla MR according to different contrast injection methods
    Yon Mi Sung
    Hwanseok Yong
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)