T1 maps in upper abdomen: comparison of Look-Locker and B1-corrected variable-flip-angle (VFA) methods

被引:1
|
作者
Wang, Zhaoqi [1 ]
Chu, Funing [1 ]
Bai, Bingmei [1 ]
Han, Shuai [1 ]
Zhang, Hongkai [1 ]
Yan, Xu [2 ]
Zhang, Shouning [1 ]
Dong, Yafeng [1 ]
Jiang, Lina [1 ]
Zhao, Yan [1 ]
Kamel, Ihab R. R. [3 ]
Li, Hailiang [1 ]
Qu, Jinrong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Siemens Ltd, NEA MR Collaborat, Shanghai 201318, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; MR relaxometry; T1; mapping; Liver; Look-locker; B1-corrected VFA; CONTRAST-ENHANCED MRI; MAGNETIC-RESONANCE; CHRONIC HEPATITIS; LIVER-CIRRHOSIS; DIAGNOSIS; ULTRASOUND; ACCURACY;
D O I
10.1007/s42058-022-00114-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeT1 mapping has been recognized as a promising tool for quantitative measurements of various tissues that may assist in accurate and tissue specific diagnosis. The purpose of this study was to compare the T1 values of two whole-liver T1 mapping methods, free-breathing Look-Locker and breath-hold B1-corrected variable-flip-angle (VFA) in diagnosing liver cirrhosis, and compare the T1 relaxation time of various upper abdominal organs using two methods.MethodsNon-enhanced T1 mapping with whole-liver coverage was performed on 85 prospectively enrolled suspicious liver tumor patients. Multiple abdominal MRI sequences were obtained. Image quality was assessed by scoring image artifacts on 5-point scale. T1 relaxation time for each organ was recorded. Statistical significance analyzed using Paired t test.ResultsT1 maps of Look-Locker method showed fewer artifacts, with score 5 in all cases compared to 36% in VFA method. There was no significant difference between cirrhotic and non-cirrhotic livers of either left or right lobe in both methods. T1 relaxation time was significantly lower (p < 0.0001) in Look-Locker than VFA method in both lobes of liver, spleen, pancreas, left kidney, right kidney, kidney cortex and medulla, erector spinae and rectus abdominis. No significant difference was found between left and right lobe of liver in both methods. T1 relaxation time of both methods was significantly lower in kidney cortex (p < 0.0001) than medulla on both left and right kidneys.ConclusionsThe choice of Look-Locker or B1-corrected VFA-based T1 mapping may affect T1 values of organs in upper abdomen. Look-Locker showed better image quality and less motion artifacts than B1-corrected VFA method.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 48 条
  • [1] T1 maps in upper abdomen: comparison of Look-Locker and B1-corrected variable-flip-angle (VFA) methods
    Zhaoqi Wang
    Funing Chu
    Bingmei Bai
    Shuai Han
    Hongkai Zhang
    Xu Yan
    Shouning Zhang
    Yafeng Dong
    Lina Jiang
    Yan Zhao
    Ihab R. Kamel
    Hailiang Li
    Jinrong Qu
    Chinese Journal of Academic Radiology, 2023, 6 : 41 - 46
  • [2] 对比Look-locker和B1-corrected VFA在肝脏T1值定量分析中的初步应用
    韩帅
    孟帆
    曲金荣
    肿瘤影像学, 2020, (05) : 489 - 494
  • [3] Using Variable Flip Angle (VFA) and Modified Look-Locker Inversion Recovery (MOLLI) T1 mapping in clinical OE-MRI
    Bluemke, Emma
    Bertrand, Ambre
    Chu, Kwun-Ye
    Syed, Nigar
    Murchison, Andrew G.
    Cooke, Rosie
    Greenhalgh, Tessa
    Burns, Brian
    Craig, Martin
    Taylor, Nia
    Shah, Ketan
    Gleeson, Fergus
    Bulte, Daniel
    MAGNETIC RESONANCE IMAGING, 2022, 89 : 92 - 99
  • [4] 探讨look-locker序列和B1-corrected VFA序列在上腹部组织T1值定量分析中的价值
    韩帅
    孟帆
    张孝先
    夏威利
    李祥
    邵楠楠
    曲金荣
    中国CT和MRI杂志, 2020, 18 (03) : 14 - 17
  • [5] T1 mapping for liver function evaluation in gadoxetic acid–enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity–corrected variable flip angle method
    Ji Eun Kim
    Hyun Ok Kim
    Kyungsoo Bae
    Dae Seob Choi
    Dominik Nickel
    European Radiology, 2019, 29 : 3584 - 3594
  • [6] Correction to: T1 mapping for liver function evaluation in gadoxetic acid–enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity–corrected variable flip angle method
    Ji Eun Kim
    Hyun Ok Kim
    Kyungsoo Bae
    Dae Seob Choi
    Dominik Nickel
    European Radiology, 2020, 30 : 672 - 672
  • [7] T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B1 inhomogeneity-corrected variable flip angle method
    Kim, Ji Eun
    Kim, Hyun Ok
    Bae, Kyungsoo
    Choi, Dae Seob
    Nickel, Dominik
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3584 - 3594
  • [8] 采用B1-corrected variable-flip-angle(VFA)的定量动态增强MRI在乳腺良恶性病变的研究
    蒋辉
    曲金荣
    宋颖
    王立峰
    刘翠翠
    张宏凯
    中国CT和MRI杂志, 2024, 22 (01) : 85 - 87
  • [9] Quantitative analysis of liver function: 3D variable-flip-angle versus Look-Locker T1 relaxometry in hepatocyte-specific contrast-enhanced liver MRI
    Verloh, Niklas
    Fuhrmann, Irene
    Fellner, Claudia
    Nickel, Dominik
    Zeman, Florian
    Kandulski, Arne
    Hornung, Matthias
    Stroszczynski, Christian
    Wiggermann, Philipp
    Haimerl, Michael
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (04) : 2509 - 2522
  • [10] Myocardial T1 Mapping With MRI: Comparison of Look-Locker and MOLLI Sequences
    Nacif, Marcelo Souto
    Turkbey, Evrim B.
    Gai, Neville
    Nazarian, Saman
    van der Geest, Rob J.
    Noureldin, Radwa A.
    Sibley, Christopher T.
    Ugander, Martin
    Liu, Songtao
    Arai, Andrew E.
    Lima, Joao A. C.
    Bluemke, David A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (06) : 1367 - 1373