Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures

被引:0
|
作者
Mandala, Meghana [1 ]
Shaunak, Shalin [2 ]
Kreitmair, Paul [3 ]
Phadnis, Joideep [2 ]
Guryel, Enis [2 ]
机构
[1] Brighton & Sussex Med Sch, Brighton, England
[2] Univ Hosp Sussex NHS Fdn Trust, Brighton, England
[3] Univ Sussex, Brighton, England
关键词
Intra-articular fractures; Headless compression screws; Locking screws; Acutrak; Synthes; Smith and Nephew; Compression force; INTERFRAGMENTARY COMPRESSION; HERBERT SCREW; LAG SCREW; FIXATION;
D O I
10.1007/s00590-023-03792-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Headless compression screws (HCS) have a variable thread pitch and headless design enabling them to embed below the articular surface and generate compression force for fracture healing without restricting movement. Locking screws have greater variety of dimensions and a threaded pitch mirroring the design of the HCS. The objective of this study is to determine whether locking screws can generate compression force and compare the compressive forces generated by HCS versus locking screws.Method A comparison between 3.5-mm HCS versus 3.5-mm locking screws and 2.8-mm HCS versus 2.7-mm locking screws was performed using a synthetic foam bone model (Synbone) and FlexiForce sensors to record the compression forces (N). The mean peak compression force was calculated from a sample of 3 screws for each screw type. Statistical analysis was performed using the one-way ANOVA test and statistical significance was determined to be p = < 0.05.Results The 3.5-mm Synthes and Smith and Nephew locking screws generated similar peak compression forces to the 3.5-mm Acutrak 2 headless compression screws with no statistically significant difference between them. The smaller 2.7-mm Synthes and Smith and Nephew locking screws initially generated similar compressive forces up to 1.5 and 2 revolutions, respectively, but their peak compression force was less compared to the 2.8-mm Micro Acutrak 2 HCS.Conclusion Locking screws are able to generate compressive forces and may be a viable alternative to headless compressive screws supporting their use for intra-articular fractures.
引用
收藏
页码:1319 / 1325
页数:7
相关论文
共 50 条
  • [1] Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures
    Meghana Mandala
    Shalin Shaunak
    Paul Kreitmair
    Joideep Phadnis
    Enis Guryel
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 1319 - 1325
  • [2] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ni, Ming
    Wong, Duo Wai-Chi
    Mei, Jiong
    Niu, Wenxin
    Zhang, Ming
    SCIENCE CHINA-LIFE SCIENCES, 2016, 59 (09) : 958 - 964
  • [3] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ming Ni
    Duo Wai-Chi Wong
    Jiong Mei
    Wenxin Niu
    Ming Zhang
    Science China Life Sciences, 2016, 59 : 958 - 964
  • [4] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ming Ni
    Duo Wai-Chi Wong
    Jiong Mei
    Wenxin Niu
    Ming Zhang
    Science China(Life Sciences), 2016, (09) : 958 - 964
  • [5] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Wang, Haili
    Yang, Zhaoxu
    Wu, Zhanpo
    Chen, Wei
    Zhang, Qi
    Li, Ming
    Li, Zhiyong
    Zhang, Yingze
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (04) : 571 - 575
  • [6] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Haili Wang
    Zhaoxu Yang
    Zhanpo Wu
    Wei Chen
    Qi Zhang
    Ming Li
    Zhiyong Li
    Yingze Zhang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 571 - 575
  • [7] Comparison of screw versus locking plate fixation via sinus tarsi approach for displaced intra-articular calcaneal fractures
    Sato, Kohei
    Yorimitsu, Masanori
    Uehara, Takenori
    Fukuoka, Shiro
    Hata, Toshiaki
    Saiga, Kenta
    Noda, Tomoyuki
    Ozaki, Toshifumi
    FOOT AND ANKLE SURGERY, 2023, 29 (01) : 97 - 102
  • [8] A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation
    Rebgetz, Paul R.
    Daniele, Luca
    Underhill, Ian D.
    Ochsner, Andreas
    Taylor, Fraser J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : E111 - E116
  • [9] Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures
    Florian Högel
    Stefanie Hoffmann
    Stefanie Panzer
    Johannes Wimber
    Volker Bühren
    Peter Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 59 - 64
  • [10] Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures
    Hoegel, Florian
    Hoffmann, Stefanie
    Panzer, Stefanie
    Wimber, Johannes
    Buehren, Volker
    Augat, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 59 - 64