Zero-sequence current suppression control for fault current damper based on model predictive control

被引:0
|
作者
Shetgaonkar, Ajay [1 ]
Popov, Marjan [1 ]
Palensky, Peter [1 ]
Lekic, Aleksandra [1 ]
机构
[1] Delft Univ Technol, Fac EEMCS, Mekelweg 4, NL-2628 CD Delft, Netherlands
关键词
Multiterminal HVdc grids; RTDS; Model predictive control; Dc circuit breakers; PROTECTION; MMC; GRIDS;
D O I
10.1016/j.epsr.2023.109592
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a multi-terminal direct current (MTdc) system based on a modular multilevel converter (MMC), high-speed and large interruption capability direct current circuit breakers (dc CBs) are required for dc fault interruption. However, commercializing these breakers is challenging, especially offshore, due to the large footprint of the surge arrester. Hence, a supplementary control is required to limit the rate of current rise along with the fault current limiter. Furthermore, the operation of the dc CB is not frequent. Thus, it can lead to delays in fault interruption. This study proposes the indirect model predictive control (MPC)-based zero-sequence current control. This control provides dc fault current suppression by continuously controlling the zero-sequence current component using circulating current suppression control (CCSC) and by providing feedback to the outer voltage loop and inner current loop of MMCs. The proposed control is simulated for pole-to-pole and pole-to-ground faults at the critical fault location of an MTdc system. The simulation is performed in Real Time Digital Simulator (RTDS) environment, which shows that the predictive control reduces the rate of rise of the fault current, providing an additional 3 ms after the dc fault occurrence to the dc CB to clear the fault. Besides, the energy absorbed by the dc CB's surge arrester during the pole-to-pole and pole-to-ground fault remains the same with the proposed control.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Analysis and Injection Control of Zero-sequence Voltage and Circulating Current for MMC with Active Power Filter
    Jia, Guanlong
    Tang, Song
    Zhang, Chenghao
    Chen, Min
    Lu, Yi
    Yang, Yong
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 1025 - 1030
  • [42] Zero-sequence current control strategy for open-end winding induction machine drive
    Luo H.
    Chang L.-C.
    Yang S.-Y.
    Xie Z.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (03): : 42 - 55
  • [43] Current Measurement suitable for Current Control System of PMSM based on Model Predictive Control
    Yokoyama, Shizuka
    Shimaoka, Masahiro
    Doki, Shinji
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 1015 - 1021
  • [44] Analysis of influence of unbalanced zero-sequence current on pilot zero-sequence protection and its countermeasures
    Tian, Baojiang
    Zhang, Taisheng
    Chen, Jun
    Zang, Rui
    Liao, Xiaoyu
    Wang, Jingjun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (19): : 132 - 135
  • [45] Model Predictive Current Control of Doubly Salient Electromagnetic Machine for Current Ripple Suppression
    Chen, Xu
    Zhang, Zhuoran
    Yu, Li
    Bian, Zhangming
    2019 IEEE INTERNATIONAL SYMPOSIUM ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2019), 2019, : 384 - 388
  • [46] Suppression Method of Unbalanced Overvoltage in Distribution Network Based on Zero-sequence Voltage Regulation and Control
    Li J.
    Zeng X.
    Yu K.
    Li L.
    Wang Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (20): : 121 - 126
  • [47] Zero-Sequence Current Suppression Strategy for Open Winding PMSG Fed by Semicontrolled Converter
    Nian, Heng
    Zhou, Yijie
    Zeng, Hengli
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (01) : 711 - 720
  • [48] Single-phase grounding fault line selection method based on zero-sequence current increment
    Hao, Bai
    ENERGY REPORTS, 2022, 8 : 305 - 312
  • [49] IMBALANCE CURRENT OF ZERO-SEQUENCE CURRENT FILTERS DURING DEEP SATURATION OF CURRENT TRANSFORMERS
    DMITRIEV, KS
    ELECTRICAL TECHNOLOGY, 1972, 5 : 150 - &
  • [50] Individual Phase Current Control Based on Optimal Zero-Sequence Current Separation for a Star-Connected Cascade STATCOM Under Unbalanced Conditions
    Shi, Youjie
    Liu, Bangyin
    Shi, Yanjun
    Duan, Shanxu
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 2099 - 2110