Agreement between cardiac output estimation with a wireless, wearable pulse decomposition analysis device and continuous thermodilution in post cardiac surgery intensive care unit patients

被引:4
|
作者
Khanna, Ashish K. K. [1 ,2 ,3 ]
Garcia, Julio O. [4 ]
Saha, Amit K. [3 ,5 ]
Harris, Lynnette [3 ,5 ]
Baruch, Martin [6 ]
Martin, R. Shayn [7 ]
机构
[1] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Sch Med, Dept Anesthesiol,Sect Crit Care Med, Winston Salem, NC 27109 USA
[2] Outcomes Res Consortium, Cleveland, OH 44195 USA
[3] Perioperat Outcomes & Informat Collaborat POIC, Winston Salem, NC 27109 USA
[4] Wake Forest Univ, Sch Med, Winston Salem, NC USA
[5] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Anesthesiol, Sch Med, Winston Salem, NC USA
[6] Caretaker Med, Charlottesville, VA USA
[7] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Surg, Sch Med, Winston Salem, NC USA
关键词
Pulse decomposition analysis; Cardiac output; Hemodynamics; Wireless; Monitoring; Cardiac surgery; Postoperative; Intensive care unit; ACCURACY; PRESSURE; NEXFIN; CNAP;
D O I
10.1007/s10877-023-01059-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
PurposePulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit.MethodsCO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone.Results259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 & PLUSMN; 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83.ConclusionCompared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [41] Correlation between Cardiac Output and Disease Severity in Intubated COVID-19 Patients: Insights from Ultrasonic Cardiac Output Monitoring in Intensive Care Unit Settings
    Hashemian, Seyed Mohammadreza
    Khoundabi, Batoul
    Jamaati, Hamidreza
    Sadr, Makan
    Safdari, Hassan
    Rashidi, Farzad
    Varahram, Mohammad
    Noraee, Navid
    Bahrami, Ashkan
    Eshraghi, Reza
    BIOMEDICAL AND BIOTECHNOLOGY RESEARCH JOURNAL, 2024, 8 (02): : 213 - 217
  • [42] Continuous non-invasive Cardiac Output Measurement by means of the Volume Clamp Method in Cardiosurgical Intensive Care Patients: A Comparison with the pulmonary arterial Thermodilution
    Wagner, J.
    Koerner, A.
    Schulte-Uentrop, L.
    Kubik, M.
    Reichenspurner, H.
    Kluge, S.
    Reuter, D. A.
    Saugel, B.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2016, 111 (04) : 387 - 387
  • [43] Dexmedetomidine Use in Intensive Care Unit Sedation and Postoperative Recovery in Elderly Patients Post-Cardiac Surgery (DIRECT)
    Chitnis, Shruti
    Mullane, Darren
    Brohan, Janette
    Noronha, Andrea
    Paje, Howard
    Grey, Rebecca
    Bhalla, Rishi K.
    Sidhu, Jesse
    Klein, Rael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (03) : 880 - 892
  • [44] Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis
    Phillip Hoppe
    Fabian Gleibs
    Luisa Briesenick
    Alexandre Joosten
    Bernd Saugel
    Journal of Clinical Monitoring and Computing, 2021, 35 : 1203 - 1209
  • [45] Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis
    Hoppe, Phillip
    Gleibs, Fabian
    Briesenick, Luisa
    Joosten, Alexandre
    Saugel, Bernd
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (05) : 1203 - 1209
  • [46] Correlation between procalcitonin, EuroSCORE and SOFA score during the intensive care unit course in patients subjected to cardiac surgery
    Maravic-Stojkovic, V
    Spasic, T.
    Jovic, M.
    Borzanovic, M.
    Djukanovic, B.
    Brunner, D.
    INFECTION, 2007, 35 : 7 - 7
  • [47] Interaction between warfarin and short-term intravenous amiodarone in intensive care unit patients after cardiac surgery
    Tomoki Takase
    Hiroaki Ikesue
    Makiko Tohi
    Hiroshi Ueta
    Hiroyuki Mima
    Tadaaki Koyama
    Tohru Hashida
    Journal of Pharmaceutical Health Care and Sciences, 4 (1)
  • [48] Interaction between warfarin and short-term intravenous amiodarone in intensive care unit patients after cardiac surgery
    Takase, Tomoki
    Ikesue, Hiroaki
    Tohi, Makiko
    Ueta, Hiroshi
    Mima, Hiroyuki
    Koyama, Tadaaki
    Hashida, Tohru
    JOURNAL OF PHARMACEUTICAL HEALTH CARE AND SCIENCES, 2018, 4
  • [49] Comparison of cardiac index measurements in intensive care patients using continuous wave vs. pulsed wave echo-Doppler compared to pulse contour cardiac output
    Prashant Parulekar
    James Powys-Lybbe
    Paul Bassett
    Seb Roques
    Mark Snazelle
    Gemma Millen
    Tim Harris
    Intensive Care Medicine Experimental, 11
  • [50] Comparison of cardiac index measurements in intensive care patients using continuous wave vs. pulsed wave echo-Doppler compared to pulse contour cardiac output
    Parulekar, Prashant
    Powys-Lybbe, James
    Bassett, Paul
    Roques, Seb
    Snazelle, Mark
    Millen, Gemma
    Harris, Tim
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2023, 11 (01)