Enantioselective separation and simulation studies of five flavanone glycosides on a cellulose tris-(3,5-dichlorophenylcarbamate) chiral stationary phase

被引:2
|
作者
Bai, Qiufang [2 ]
Yu, Youyang [1 ]
Zhao, Pan [5 ]
Yang, Yueyao [1 ]
Zhang, Yaowen [6 ,7 ]
Tan, Chao [2 ]
Zhu, Yingying [8 ]
Fang, Linlin [1 ]
Li, Linwei [3 ,4 ]
机构
[1] Dalian Med Univ, Coll Pharm, Dalian 116044, Peoples R China
[2] Dalian Univ, Affiliated Zhongshan Hosp, Dept Pharm, Dalian 116000, Peoples R China
[3] Inst Bot, Jiangsu Key Lab Res & Utilizat Plant Resources, Nanjing 210014, Jiangsu, Peoples R China
[4] Chinese Acad Sci, Nanjing 210014, Peoples R China
[5] Shandong Univ Tradit Chinese Med, Coll Pharm, Jinan 250355, Peoples R China
[6] Examinat & Certificat Ctr, Liaoning Inspect, Shenyang 110036, Peoples R China
[7] Liaoning Inst Drug Control, Shenyang 110036, Peoples R China
[8] Daicel Chiral Technol Co Ltd, Shanghai 200131, Peoples R China
关键词
Chiral separation; Molecular modeling; Intermolecular forces; Flavanone glycosides; HPLC SEPARATION; ENANTIOMERIC RESOLUTION; ENANTIOSEPARATION; RECOGNITION; DERIVATIVES; NARINGENIN; MECHANISMS; ABILITY; SAMPLES;
D O I
10.1016/j.molliq.2023.121260
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, the chiral separation of five flavanone glycosides was first examined on the cellulose tris-(3,5-dichlorophenylcarbamate) (CDCPC) chiral stationary phase (CSP) in the normal phase mode. The influence of acid additives, the type and proportion of organic modifiers, and column temperature were systematically evaluated and optimized. Under the optimum chromatographic conditions, hesperidin, eriocitrin, neohesperidin, naringin and narirutin enantiomers were completely or partially separated with resolutions of 2.56, 2.28, 1.84, 2.94 and 0.85. Moreover, to gain a better understanding of the chiral recog-nition mechanism, detailed computational simulations of CDCPC interacting with five pairs of enan-tiomers were carried out using molecular docking. The docking result demonstrated that the chiral recognition of analytes on CDCPC was an exothermic process which governed hydrogen bond, hydropho-bic and unfavorable interaction. This work hoped to provide some guidance for the subsequent analysis of flavanone glycosides. (c) 2023 Published by Elsevier B.V.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Enantioselective determination of a gastroprokinetic drug using amylose tris-(3,5-dimethylphenylcarbamate) as a stationary phase by HPLC
    Rao, RN
    Nagaraju, D
    Narasaraju, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (02) : 338 - 344
  • [32] Analytical and preparative enantioseparations in supercritical fluid chromatography using different brands of immobilized cellulose tris (3,5-dichlorophenylcarbamate) columns: Some differences
    Dascalu, Anca-Elena
    Speybrouck, David
    Billamboz, Muriel
    Corens, David
    Ghinet, Alina
    Lipka, Emmanuelle
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1622
  • [33] Chiral Resolution of Cypermethrin on Cellulose-tris(3,5-dimethylphenyl-carbamate) Chiral Stationary Phase
    Peng Wang
    Zhiqiang Zhou
    Shuren Jiang
    Li Yang
    Chromatographia, 2004, 59 : 625 - 629
  • [34] Chiral resolution of cypermethrin on cellulose-tris(3,5-dimethylphenyl-carbamate) chiral stationary phase
    Wang, P
    Zhou, ZQ
    Jiang, SR
    Yang, L
    CHROMATOGRAPHIA, 2004, 59 (9-10) : 625 - 629
  • [35] Chiral separation of racemic epoxiconazole on cellulose tris (3,5-dimethylphenylcarbamate) chiral stationary phase using high performance liquid chromatography
    Han Xiaoqian
    Wei Yan
    Liu Yanhua
    Chang Jing
    Qiu Wei
    Chen Feng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (05) : 631 - 633
  • [36] Enantioseparation of Novel Chiral Tetrahedral Clusters on an Amylose Tris-(3,5-dimethylphenylcarbamate) Chiral Stationary Phase by Normal Phase HPLC
    李文智
    王霞
    张伟强
    陈立仁
    李永民
    马春林
    殷元骐
    Chinese Journal of Chemistry, 2004, (10) : 1070 - 1074
  • [37] Enantioseparation of novel chiral tetrahedral clusters on an amylose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase by normal phase HPLC
    Li, WZ
    Wang, X
    Zhang, WQ
    Chen, LR
    Li, YM
    Ma, CL
    Yin, YQ
    CHINESE JOURNAL OF CHEMISTRY, 2004, 22 (10) : 1070 - 1074
  • [38] Enantioselective separation of indole derivatives by liquid chromatography using immobilized cellulose (3,5-dimethylphenylcarbamate) chiral stationary phase
    Liang Zhao
    Yongfei Ming
    Hongli Zhang
    Shengxiang Jiang
    Journal of Analytical Chemistry, 2009, 64 : 795 - 805
  • [39] Enantioselective separation of indole derivatives by liquid chromatography using immobilized cellulose (3,5-dimethylphenylcarbamate) chiral stationary phase
    Zhao, Liang
    Ming, Yongfei
    Zhang, Hongli
    Jiang, Shengxiang
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (08) : 795 - 805
  • [40] Direct optical resolution of the enantiomers of novel chiral tetrahedral metal clusters by HPLC on a cellulose tris-(3,5-dimethylphenylcarbamate) stationary phase
    Wenzhi Li
    Weiqiang Zhang
    Quanyi Zhao
    Yongmin Li
    Chunlin Ma
    Liren Chen
    Yuanqi Yin
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1364 - 1368