共 22 条
Analytical and preparative enantioseparations in supercritical fluid chromatography using different brands of immobilized cellulose tris (3,5-dichlorophenylcarbamate) columns: Some differences
被引:8
|作者:
Dascalu, Anca-Elena
[1
,2
,3
,4
]
Speybrouck, David
[5
]
Billamboz, Muriel
[1
,2
]
Corens, David
[6
]
Ghinet, Alina
[1
,2
,4
]
Lipka, Emmanuelle
[1
,3
]
机构:
[1] Univ Lille, U1167 Inserm RID AGE, F-59000 Lille, France
[2] UCLille, Ecole Hautes Etud Ingenieur HEI, Team Sustainable Chem,Hlth & Environm Dept, Yncrea Hauts France,Lab Sustainable Chem & Hlth, 13 Rue Toul, F-59046 Lille, France
[3] UFR Pharm, Lab Chim Analyt, BP 83, F-59006 Lille, France
[4] Alexandru Ioan Cuza Univ, Fac Chem, Bd Carol I 11, Iasi 700506, Romania
[5] Discovery Sci, Janssen Res & Dev, Campus Maigremont, F-27106 Val De Reuil, France
[6] Janssen Pharmaceut NV, Janssen Res & Dev, Discovery Sci, Turnhoutseweg 30, B-2340 Beerse, Belgium
关键词:
Cellulose tris (3,5-dichlorophenylcarbamate);
Enantiomers;
Loadability;
Manufacturers;
Supercritical fluid chromatography;
CHIRAL STATIONARY PHASES;
DRUG DISCOVERY;
RECOGNITION MECHANISM;
SEPARATION;
SILICA;
DERIVATIVES;
RESOLUTION;
INSIGHTS;
AMYLOSE;
HPLC;
D O I:
10.1016/j.chroma.2020.461125
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
The aim of this study was to determine the impact of the origin and the manufacturing processes of the chiral stationary phases (CSPs) on their chromatographic behaviors. Hence, four chiral stationary phases based on immobilized tris (3,5-dichlorophenylcarbamate) derivative of cellulose supplied by four different manufacturers were evaluated. A set of twenty-nine compounds, including commercially available and inhouse synthesized compounds, with a broad range of lipophilicity and polarity was chosen. Three main parameters were evaluated on all stationary phases: retention factor, selectivity and loading capacity. This work highlighted that the retention factor strongly varied according to the manufacturer. Regardless of the characteristic of the tested compounds i.e. neutral, acidic or basic, there was a trend in retention ability of the four chiral stationary phases: retention was increasing from CHIRAL ART Cellulose-SC, REFLECT I-Cellulose C, Chiralpak IC to Lux i-Cellulose-5. On the contrary, selectivity did not follow the same trend as retention. The difference in selectivity between each column towards one compound was quite low while the difference in resolution depended on the nature of the compounds investigated and was significant in certain cases. Finally, the four different columns presented similar and high loading capacity. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文