Selective Detection of Creatinine Using Enzymatic Route for Diagnosis of Chronic Kidney Diseases

被引:1
|
作者
Kavita [1 ]
Verma, R. K. [2 ]
机构
[1] Cent Univ Rajasthan, Dept Phys, NH-8 Bandarsindri, Ajmer 305817, Rajasthan, India
[2] Univ Allahabad, Dept Phys, Prayagraj 211002, Uttar Pradesh, India
关键词
SnO2; nanorods; creatinine; creatininase; biosensor; chronic kidney disease; SERUM CREATININE; GRAPHENE OXIDE; DOPED SNO2; SENSOR; URINE; UREA; RISK; ACID;
D O I
10.1149/1945-7111/ad2284
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Chronic kidney diseases are becoming most common health issues due to growing age, hypertension and high cholesterol that causes poor kidney functioning and eventually death also. Creatinine is a serum present in blood and urine that measures the kidney functioning. We have designed a highly sensitive and precise sensor for the creatinine sensing. Eu-doping in tin oxide (SnO2) is used to enhance the sensitivity and limit of detection. A precise working range of this sensor is also found by the calibration curve between FWHM and figure of Merit with respect to the concentration of creatinine. A selectivity experiment with enzymatic route is followed to make this sensor selective for creatinine only. This sensor may find plentiful deliberation in the field of sensing and mainly in medical applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Timely Diagnosis of Acute Kidney Injury Using Kinetic eGFR and the Creatinine Excretion to Production Ratio, E/eG - Creatinine Can Be Useful!
    Endre, Zoltan H.
    Pianta, Timothy J.
    Pickering, John W.
    NEPHRON, 2016, 132 (04) : 312 - 316
  • [42] A Survey on Chronic Kidney Disease Diagnosis using Fuzzy Logic
    Bhatt, Madhur
    Kasbe, Tanmay
    2019 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2019), 2019, : 252 - 256
  • [43] THE PRINCIPLES OF USING RADIONUCLIDS IN THE DIAGNOSIS OF KIDNEY-DISEASES HAVE CHANGED
    HOR, G
    HEIDENREICH, P
    PABST, HW
    MEDIZINISCHE KLINIK, 1980, 75 (17) : 42 - &
  • [44] Non-Enzymatic Electrochemical Detection of Urine Creatinine Using Cobalt-Gold Bimetallic Nanoparticles
    Meera, R.
    Neena, P. K.
    Pradeep, Aarathi
    Nair, Bipin G.
    Vasu, Suneesh Punathil
    Babu, T. G. Satheesh
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (06)
  • [45] Time to appreciate Avicenna's diagnosis of chronic kidney diseases based on examination of the urine
    Aghakhani, Nader
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2021, 32 (02) : 595 - 596
  • [46] Enzymatic detection of glucose using fluoride-selective electrodes with polymeric membranes
    Łukasz Górski
    Dorota Klimaszewska
    Mariusz Pietrzak
    Elżbieta Malinowska
    Analytical and Bioanalytical Chemistry, 2007, 389 : 533 - 539
  • [47] Enzymatic detection of glucose using fluoride-selective electrodes with polymeric membranes
    Gorski, Lukasz
    Klimaszewska, Dorota
    Pietrzak, Mariusz
    Malinowska, Elzbieta
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (02) : 533 - 539
  • [48] Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires
    Zhang, Yuchan
    Su, Liang
    Manuzzi, Dan
    de los Monteros, Honorio Valdes Espinosa
    Jia, Wenzhao
    Huo, Danqun
    Hou, Changjun
    Lei, Yu
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 426 - 432
  • [49] Correlation of Kidney Size on Computed Tomography with GFR, Creatinine and HbA1C for an Accurate Diagnosis of Patients with Diabetes and/or Chronic Kidney Disease
    Ghaith, Nashaat
    Malaeb, Bassem
    Itani, Rasha
    Alnafea, Mohammed
    Al Faraj, Achraf
    DIAGNOSTICS, 2021, 11 (05)
  • [50] Role of polyelectrolyte multilayers over gold film for selective creatinine detection using Raman spectroscopy
    Karn-orachai, Kullavadee
    Ngamaroonchote, Aroonsri
    APPLIED SURFACE SCIENCE, 2021, 546