Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires

被引:288
|
作者
Zhang, Yuchan [1 ]
Su, Liang [2 ]
Manuzzi, Dan [2 ]
de los Monteros, Honorio Valdes Espinosa [2 ]
Jia, Wenzhao [2 ]
Huo, Danqun [1 ]
Hou, Changjun [1 ]
Lei, Yu [2 ]
机构
[1] Chongqing Univ, Key Lab Biorheol Sci & Technol, Minist Educ, Bioengn Coll, Chongqing 400030, Peoples R China
[2] Univ Connecticut, Dept Chem Mat & Biomol Engn, Storrs, CT 06269 USA
来源
BIOSENSORS & BIOELECTRONICS | 2012年 / 31卷 / 01期
基金
美国国家科学基金会;
关键词
Copper nanowire; Electrooxidation; Glucose; Non-enzymatic; Sensor; CARBON NANOTUBES; ELECTROCHEMICAL DETECTION; SENSOR; BIOSENSORS; ELECTRODE; PLATINUM; NANOPARTICLES; NANOSTRUCTURES; OXIDATION; ARRAYS;
D O I
10.1016/j.bios.2011.11.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the pursuit of more economical electrocatalysts for non-enzymatic glucose sensors, one-dimensional Cu nanowires (Cu NWs) with uniform size distribution and a large aspect ratio (>200) were synthesized by a facile, scalable, wet-chemistry approach. The morphology, crystallinity, and surface property of the as-prepared Cu NWs were examined by SEM, XRD, and XPS, respectively. The electrochemical property of Cu NWs for glucose electrooxidation was thoroughly investigated by cyclic voltammetry. In the amperometric detection of glucose, the Cu NWs modified glassy carbon electrode exhibited an extraordinary limit of detection as low as 35 nM and a wide dynamic range with excellent sensitivity of 420.3 mu A cm(-2) mM(-1), which was more than 10,000 times higher than that of the control electrode without Cu NWs. The performance of the developed glucose sensor was also independent to oxygen concentration and free from chloride poisoning. Furthermore, the interference from uric acid, ascorbic acid, acetaminophen, fructose, and sucrose at the level of their physiological concentration were insignificant, indicating excellent selectivity. Finally, good accuracy and high precision for the quantification of glucose concentration in human serum samples implicate the applicability of Cu NWs in sensitive and selective non-enzymatic glucose detection. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [1] Nanostructured copper selenide as an ultrasensitive and selective non-enzymatic glucose sensor
    Umapathi, Siddesh
    Singh, Harish
    Masud, Jahangir
    Nath, Manashi
    [J]. MATERIALS ADVANCES, 2021, 2 (03): : 927 - 932
  • [2] Monodisperse copper selenide nanoparticles for ultrasensitive and selective non-enzymatic glucose biosensor
    Hao, Xiaokai
    Jia, Jingchun
    Chang, Ying
    Jia, Meilin
    Wen, Zhenhai
    [J]. ELECTROCHIMICA ACTA, 2019, 327
  • [3] CuO nanowires based sensitive and selective non-enzymatic glucose detection
    Zhang, Yuchan
    Liu, Yixin
    Su, Liang
    Zhang, Zhonghua
    Huo, Danqun
    Hou, Changjun
    Lei, Yu
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 86 - 93
  • [4] Ultrasensitive and highly selective sandpaper-supported copper framework for non-enzymatic glucose sensor
    Hou, Lei
    Zhao, Hang
    Bi, Siyi
    Xu, Yumeng
    Lu, Yinxiang
    [J]. ELECTROCHIMICA ACTA, 2017, 248 : 281 - 291
  • [5] Nanoporous cobalt oxide nanowires for non-enzymatic electrochemical glucose detection
    Kang, Luqi
    He, Daiping
    Bie, Lili
    Jiang, Ping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 888 - 894
  • [6] Copper and Nickel Microsensors Produced by Selective Laser Reductive Sintering for Non-Enzymatic Glucose Detection
    Tumkin, Ilya I.
    Khairullina, Evgeniia M.
    Panov, Maxim S.
    Yoshidomi, Kyohei
    Mizoshiri, Mizue
    [J]. MATERIALS, 2021, 14 (10)
  • [7] Non-enzymatic glucose detection using magnetic nanoemulsions
    Mahendran, V.
    Philip, John
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (12)
  • [8] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288
  • [9] Facile two-step Electrodeposition Synthesis of CuO Nanowires for Ultrasensitive Non-Enzymatic Sensing of Glucose
    Zhang, Di
    Wei, Yuyun
    Zhao, Meidan
    Wang, Hong
    Xia, Qing
    Fang, Yuxin
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (12): : 10835 - 10847
  • [10] Non-enzymatic detection of glucose using poly(azure A)-nickel
    Liu, Tong
    Luo, Yiqun
    Zhu, Jiaming
    Kong, Liyan
    Wang, Wen
    Tan, Liang
    [J]. TALANTA, 2016, 156 : 134 - 140