Diagnostic validation of smart wearable device embedded with single-lead electrocardiogram for arrhythmia detection

被引:3
|
作者
Niu, Yonghong [1 ]
Wang, Hao [2 ]
Wang, Hong [3 ,4 ]
Zhang, Hui [3 ]
Jin, Zhigeng [3 ]
Guo, Yutao [3 ]
机构
[1] Tsinghua Univ, Affiliated Hosp 1, Dept Cardiol, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 2, Natl Clin Res Ctr Geriatr Dis, Dept Cardiol, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 6, Dept Pulm Vessel & Thrombot Dis, 5 Fucheng Rd, Beijing 100048, Peoples R China
[4] Peoples Liberat Army Gen Hosp, Grad Sch, Beijing, Peoples R China
来源
DIGITAL HEALTH | 2023年 / 9卷
关键词
Atrial fibrillation; atrial premature beats; single-lead ECG; ventricular premature beats; wearables; ATRIAL-FIBRILLATION; MANAGEMENT;
D O I
10.1177/20552076231198682
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
ObjectiveTo validate a single-lead electrocardiogram algorithm for identifying atrial fibrillation, atrial premature beats, ventricular premature beats, and sinus rhythm.MethodsA total of 656 subjects aged 19 to 94 years were enrolled. Participants were simultaneously tested with a wristwatch (Huawei Watch GT2 Pro, Huawei Technologies Co., Ltd, Shenzhen, China) and a 12-lead electrocardiogram for 3 minutes. A total of 1926 electrocardiogram signals from 628 subjects (282 men and 346 women) aged 19 to 94 years (median 64 years) were analyzed using an algorithm.ResultsThe numbers of subjects with atrial fibrillation, atrial premature beats, ventricular premature beats, and sinus rhythm were 129, 141, 107, and 251, respectively, and together they had a total of 1926 electrocardiogram signals. For the three-class classification system, the recall, precision, and F1 score were 97.6%, 96.5%, 97.0% for sinus rhythm; 96.7%, 96.9%, 96.8% for atrial fibrillation; and 92.8%, 94.2%, 93.5% for ectopic beats, respectively. The macro-F1 score of the three-class classification system was 95.8%. For the four-class classification system, the recall, precision, and F1 score were 97.6%, 96.5%, 97.0% for sinus rhythm; 96.7%, 96.9%, 96.8% for atrial fibrillation; 90.5%, 89.4%, 89.9% for atrial premature beats; and 86.1%, 89.6%, 87.8% for ventricular premature beats, respectively. The macro-F1 score of the four-class classification system was 92.9%.ConclusionsThe single-lead electrocardiogram algorithm embedded into smart wearables demonstrated good performance in detecting atrial fibrillation, atrial/ventricular premature beats, and sinus rhythm, and thus would facilitate atrial fibrillation screening and management.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] An implantable loop recorder or smartphone based single-lead electrocardiogram to detect arrhythmia in adults with congenital heart disease?
    Koole, Maarten A.
    Kauw, Dirkjan
    Kooiman, Kirsten M.
    de Groot, Joris R.
    Robbers-Visser, Danielle
    Tulevski, Igor I.
    Mulder, Barbara J.
    Bouma, Berto J.
    Schuuring, Mark J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [22] A Sleep Apnea Detection Method Based on Unsupervised Feature Learning and Single-Lead Electrocardiogram
    Feng, Kaicheng
    Qin, Hengji
    Wu, Shan
    Pan, Weifeng
    Liu, Guanzheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [23] Diagnostic accuracy of a single-lead portable ECG device for measuring QTc prolongation
    Bekker, Charlotte L.
    Noordergraaf, Fauve
    Teerenstra, Steven
    Pop, Gheorghe
    van den Bemt, Bart J. F.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2020, 25 (01)
  • [24] Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery
    Hyun, Seungji
    Lee, Seungwook
    Hong, Yu Sun
    Lim, Sang-hyun
    Kim, Do Jung
    JOURNAL OF CHEST SURGERY, 2024, 57 (02): : 205 - 212
  • [25] Validation Of Automatic Absence Seizures Detection In Single-Lead Frontal EEG
    Loeckx, D.
    Buckinx, T.
    Lagae, L.
    EPILEPSIA, 2019, 60 : 197 - 197
  • [26] Research on a Lightweight Arrhythmia Classification Model Based on Knowledge Distillation for Wearable Single-Lead ECG Monitoring Systems
    An, Xiang
    Shi, Shiwen
    Wang, Qian
    Yu, Yansuo
    Liu, Qiang
    SENSORS, 2024, 24 (24)
  • [27] Deep Learning Models for Predicting Left Heart Abnormalities From Single-Lead Electrocardiogram for the Development of Wearable Devices
    Sato, Masataka
    Kodera, Satoshi
    Setoguchi, Naoto
    Tanabe, Kengo
    Kushida, Shunichi
    Kanda, Junji
    Saji, Mike
    Nanasato, Mamoru
    Maki, Hisataka
    Fujita, Hideo
    Kato, Nahoko
    Watanabe, Hiroyuki
    Suzuki, Minami
    Takahashi, Masao
    Sawada, Naoko
    Yamasaki, Masao
    Sawano, Shinnosuke
    Katsushika, Susumu
    Shinohara, Hiroki
    Takeda, Norifumi
    Fujiu, Katsuhito
    Daimon, Masao
    Akazawa, Hiroshi
    Morita, Hiroyuki
    Komuro, Issei
    CIRCULATION JOURNAL, 2024, 88 (01) : 146 - +
  • [28] A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices
    Chen, Chieh-Li
    Chuang, Chun-Te
    SENSORS, 2017, 17 (09)
  • [29] Electrocardiogram lead conversion from single-lead blindly-segmented signals
    Sofia C. Beco
    João Ribeiro Pinto
    Jaime S. Cardoso
    BMC Medical Informatics and Decision Making, 22
  • [30] Six-lead device superior to single-lead smartwatch ECG in atrial fibrillation detection
    Scholten, Josca
    Jansen, Ward P. J.
    Horsthuis, Thomas
    Mahes, Anuska D.
    Winter, Michiel M.
    Zwinderman, Aeilko H.
    Keijer, Jan T.
    Minneboo, Madelon
    de Groot, Joris R.
    Bokma, Jouke P.
    AMERICAN HEART JOURNAL, 2022, 253 : 53 - 58