An implantable loop recorder or smartphone based single-lead electrocardiogram to detect arrhythmia in adults with congenital heart disease?

被引:4
|
作者
Koole, Maarten A. [1 ,2 ,3 ]
Kauw, Dirkjan [4 ]
Kooiman, Kirsten M. [1 ]
de Groot, Joris R. [1 ]
Robbers-Visser, Danielle [1 ]
Tulevski, Igor I. [2 ]
Mulder, Barbara J. [1 ]
Bouma, Berto J. [1 ]
Schuuring, Mark J. [1 ,5 ,6 ]
机构
[1] Univ Amsterdam, Dept Cardiol, Amsterdam UMC, Amsterdam, Netherlands
[2] Cardiol Ctr Netherlands, Amsterdam, Netherlands
[3] Rode Kruis Ziekenhuis Beverwijk, Dept Cardiol, Beverwijk, Netherlands
[4] Haga Teaching Hosp, Dept Cardiol, The Hague, Netherlands
[5] Netherlands Heart Inst, Utrecht, Netherlands
[6] UMC Utrecht, Dept Cardiol, Utrecht, Netherlands
来源
关键词
arrhythmias; congenital heart disease; electrocardiography; telemedicine; implantable loop recorder; cardiology; pacemaker; eHealth; TRANSIENT ISCHEMIC ATTACK; SUDDEN CARDIAC DEATH; ATRIAL-FIBRILLATION; EUROPEAN-SOCIETY; STROKE; MANAGEMENT; STATEMENT; RISK;
D O I
10.3389/fcvm.2022.1099014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe European Society of Cardiology (ESC) guidelines for the management of adult congenital heart disease (ACHD) recommend screening in patients at risk for arrhythmic events. However, the optimal mode of detection is unknown. MethodsBaseline and follow-up data of symptomatic ACHD patients who received an implantable loop recorder (ILR) or who participated in a smartphone based single-lead electrocardiogram study were collected. The primary endpoint was time to first detected arrhythmia. ResultsIn total 116 ACHD patients (mean age 42 years, 44% male) were studied. The ILR group (n = 23) differed from the smartphone based single-lead electrocardiogram group (n = 93) in having a greater part of males and had more severe CHD and (near) syncope as qualifying diagnosis. In the smartphone based single-lead electrocardiogram group history of arrhythmia and palpitations were more frequent (all p < 0.05). Monitoring was performed for 40 and 79 patient-years for the ILR- and smartphone based single-lead electrocardiogram group, respectively. Arrhythmias occurred in 33 patients with an equal median time for both groups to first arrhythmia of 3 months (HR of 0.7, p = 0.81). Furthermore, atrial fibrillation occurred most often (n = 16) and common therapy changes included medication changes (n = 7) and implantation of pacemaker or Implantable Cardioverter Defibrillator (ICD) (N = 4). Symptoms or mode of detection were not a determinant of the first event. ConclusionNon-invasive smartphone based single-lead electrocardiogram monitoring could be an acceptable alternative for ILR implantation in detecting arrhythmia in symptomatic ACHD patients in respect to diagnostic yield, safety and management decisions, especially in those without syncope.
引用
收藏
页数:8
相关论文
共 18 条
  • [1] Implantable loop recorder for monitoring patients with congenital heart disease
    Huntgeburth, Michael
    Hohmann, Christopher
    Ewert, Peter
    Freilinger, Sebastian
    Nagdyman, Nicole
    Neidenbach, Rhoia
    Pieper, Lars
    Pieringer, Felix
    Lennerz, Carsten
    Kaemmerer, Harald
    Kolb, Christof
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2021, 11 (06) : 1334 - 1343
  • [2] USE OF A SINGLE-LEAD ECG IN THE DETECTION OF CONGENITAL HEART DISEASE
    MORTON, W
    LLOYD, L
    DODGE, HJ
    HOFFMAN, MS
    AMA JOURNAL OF DISEASES OF CHILDREN, 1958, 95 (05): : 492 - 497
  • [3] Detection of arrhythmias in adult congenital heart disease patients with LINQ implantable loop recorder
    Dodeja, Anudeep K.
    Thomas, Courtney
    Daniels, Curt J.
    Kertesz, Naomi
    Kamp, Anna
    CONGENITAL HEART DISEASE, 2019, 14 (05) : 745 - 751
  • [4] Modified positioning of a smartphone based single-lead electrocardiogram device improves detection of atrial flutter
    Rajakariar, Kevin
    Koshy, Anoop N.
    Sajeev, Jithin K.
    Nair, Sachin
    Roberts, Louise
    Teh, Andrew W.
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (05) : 884 - 888
  • [5] Implantable cardioverter defibrillators in adults with congenital heart disease: A single center experience
    Dore, A
    Santagata, P
    Dubuc, M
    Mercier, LA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (01): : 47 - 51
  • [6] Single-centre use of implantable loop recorders in patients with congenital heart disease
    Kenny, Damien
    Chakrabarti, Shanta
    Ranasinghe, Aruna
    Chambers, Amy
    Martin, Robin
    Stuart, Graham
    EUROPACE, 2009, 11 (03): : 303 - 307
  • [7] IMPLANTABLE LOOP RECORDERS IN ADULT CONGENITAL HEART DISEASE: A SINGLE-CENTRE EXPERIENCE
    Tabassum, Rahim
    Okeke, Zita
    Arif, Sayqa
    Clift, Paul
    Bowater, Sarah
    Thorne, Sara
    Marshall, Howard
    de Bono, Joseph
    Hudsmith, Lucy
    HEART, 2017, 103 : A1 - A1
  • [8] Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease
    Solano, A
    Menozzi, C
    Maggi, R
    Donateo, P
    Bottoni, N
    Lolli, G
    Tomasi, C
    Croci, F
    Oddone, D
    Puggioni, E
    Brignole, M
    EUROPEAN HEART JOURNAL, 2004, 25 (13) : 1116 - 1119
  • [9] SCNN: Scalogram-based convolutional neural network to detect obstructive sleep apnea using single-lead electrocardiogram signals
    Mashrur, Fazla Rabbi
    Islam, Md. Saiful
    Saha, Dabasish Kumar
    Islam, S. M. Riazul
    Moni, Mohammad Ali
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 134
  • [10] Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease
    Cooper, JM
    Stephenson, EA
    Berul, CI
    Walsh, EP
    Epstein, LM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 137A - 137A