Direct quantification of optic nerve blood flow by 3D pseudo-continuous arterial spin labeling

被引:0
|
作者
Wang, Qian [1 ]
Li, Ligeng [5 ]
Wang, Huaizhou [2 ,3 ]
Chen, Weiwei [2 ,3 ]
Yang, Bingbing [1 ]
Qu, Xiaoxia [1 ]
Sun, Yunxiao [2 ,3 ]
Chai, Zihan [1 ]
Li, Ting [1 ]
Chen, Jianhong [4 ]
Meng, Gang [5 ]
Gong, Xiangyu [5 ]
Wang, Ningli [2 ,3 ,6 ]
Xian, Junfang [1 ,7 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Radiol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Tongren Hosp, Beijing Inst Ophthalmol, Beijing Tongren Eye Ctr, Beijing, Peoples R China
[3] Beijing Ophthalmol & Visual Sci Key Lab, Beijing, Peoples R China
[4] Capital Med Univ, Beijing Tongren Hosp, Dept Gastroenterol, Beijing, Peoples R China
[5] AnImage Beijing Technol Co Ltd, Beijing, Peoples R China
[6] Capital Med Univ, Beijing Tongren Hosp, Beijing Tongren Eye Ctr, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China
[7] Capital Med Univ, Beijing Tongren Hosp, Dept Radiol, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China
基金
中国国家自然科学基金;
关键词
Optic nerve; Blood flow; Three-dimensional pseudocontinuous arterial; spin labeling; NnFormer;
D O I
10.1016/j.jneumeth.2023.110007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Blood perfusion of the optic nerve (ON) plays a key role in many optic neuropathies. Microvascular changes precede or accompany neuronal changes, and detecting these changes at an early stage may facilitate early treatment to avoid blindness. However, the quantification of ON blood perfusion remains a challenge. This study aimed to evaluate the viability of three-dimensional pseudocontinuous arterial spin labelling (3D-pCASL) MRI for the quantification of ON blood flow (BF). New method: The ON segmentation was performed using nnFormer on a cohort of ten participants (4 males, 6 females, 25-59 years old). Subsequently, the mean BF of each ON segment was calculated using whole brain 3DpCASL image data. Results: The average ON-BF values of the left and right intraorbital segments, left and right intracanalicular segments, left and right intracranial segments, optic chiasma, and left and right optic tract were 41.308 mL/100 g/min, 43.281 mL/100 g/min, 53.188 mL/100 g/min, 57.202 mL/100 g/min, 45.089 mL/100 g/min, 49.554 mL/100 g/min, 42. 326 mL/100 g/min, 43.831 mL/100 g/min and 45.176 mL/100 g/min, respectively. The ONBF correlated with cerebral BF (r = 0.503, p = 0.024). Comparison with existing method(s): The 3D-pCASL can measure tissue microvascular blood perfusion in absolute quantitative units with good test-retest repeatability over a wide field of view and without restrictions on depth. The use of the nnFormer makes the measurement easy, objective and reproducible. Conclusions: The study showed that, 3D-pCASL may be a promising tool for detecting abnormal ON-BF. In particular, 3D-pCASL coupled with the nnFormer provides an objective, reproducible, and reliable method to quantify BF in ON.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Selective multivessel labeling approach for perfusion territory imaging in pseudo-continuous arterial spin labeling
    Helle, Michael
    Ruefer, Susanne
    van Osch, Matthias J. P.
    Jansen, Olav
    Norris, David G.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 214 - 219
  • [42] Effect of labelling plane angulation and position on labelling efficiency and cerebral blood flow quantification in pseudo-continuous arterial spin labelling
    Sokolska, Magdalena
    Bainbridge, Alan
    Rojas-Villabona, Alvaro
    Golay, Xavier
    Thomas, David L.
    MAGNETIC RESONANCE IMAGING, 2019, 59 : 61 - 67
  • [43] Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
    Boudes, Elodie
    Gilbert, Guillaume
    Leppert, Ilana Ruth
    Tan, Xianming
    Pike, G. Bruce
    Saint-Martin, Christine
    Wintermark, Pia
    NEUROIMAGE-CLINICAL, 2014, 6 : 126 - 133
  • [44] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Zhiye Chen
    Xiaoyan Chen
    Mengyu Liu
    Mengqi Liu
    Lin Ma
    Shengyuan Yu
    The Journal of Headache and Pain, 2018, 19
  • [45] Can 3D Pseudo-Continuous Territorial Arterial Spin Labeling Effectively Diagnose Patients With Recanalization of Unilateral Middle Cerebral Artery Stenosis?
    Wang, Xinyu
    Dou, Weiqiang
    Dong, Dong
    Wang, Xinyi
    Chen, Xueyu
    Chen, Kunjian
    Mao, Huimin
    Guo, Yu
    Zhang, Chao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (01) : 175 - 183
  • [46] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Chen, Zhiye
    Chen, Xiaoyan
    Liu, Mengyu
    Liu, Mengqi
    Ma, Lin
    Yu, Shengyuan
    JOURNAL OF HEADACHE AND PAIN, 2018, 19
  • [47] (-)-Linalool influence on the cerebral blood flow in healthy male volunteers revealed by three-dimensional pseudo-continuous arterial spin labeling
    Ota, Miho
    Sato, Noriko
    Sone, Daichi
    Ogura, Jun
    Kunugi, Hiroshi
    INDIAN JOURNAL OF PSYCHIATRY, 2017, 59 (02) : 225 - 227
  • [48] Test-Retest Reproducibility of Cerebral Blood Flow Measurements Using Pseudo-continuous Arterial Spin labeling at 1.5T
    Sohn, Chul-ho
    Kim, Ji-Hoon
    Choi, Seung Hong
    Han, Moon Hee
    Chang, Kee-Hyun
    Song, In-chan
    Jahng, Geon-Ho
    Yun, Tae-Jin
    STROKE, 2011, 42 (03) : E287 - E287
  • [49] Diffusion prepared pseudo-continuous arterial spin labeling reveals blood–brain barrier dysfunction in patients with CADASIL
    Chen Ling
    Jinyuan Zhang
    Xingfeng Shao
    Li Bai
    Zhixin Li
    Yunchuang Sun
    Fan Li
    Zhaoxia Wang
    Rong Xue
    Yan Zhuo
    Qi Yang
    Zihao Zhang
    Danny J. J. Wang
    Yun Yuan
    European Radiology, 2023, 33 : 6959 - 6969
  • [50] Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling
    Hernandez-Garcia, Luis
    Jahanian, Hesamoddin
    Greenwald, Mark K.
    Zubieta, Jon-Kar
    Peltier, Scott J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1570 - 1577