Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling

被引:9
|
作者
Hernandez-Garcia, Luis [1 ,2 ]
Jahanian, Hesamoddin [2 ]
Greenwald, Mark K. [3 ]
Zubieta, Jon-Kar [4 ]
Peltier, Scott J. [1 ,2 ]
机构
[1] Univ Michigan, Funct MRI Lab, Ann Arbor, MI 48105 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48105 USA
[3] Wayne State Univ, Sch Med, Dept Psychiat & Neurosci, Detroit, MI USA
[4] Univ Michigan, Dept Psychiat, Ann Arbor, MI 48105 USA
关键词
arterial spin labeling; real time; fMRI; PERFUSION-BASED FMRI; CEREBRAL-BLOOD-FLOW; BRAIN ACTIVATION; DESIGN; BOLD; SENSITIVITY; MODEL; QUANTIFICATION; OPTIMIZATION; FEASIBILITY;
D O I
10.1002/mrm.22922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The first implementation of real-time acquisition and analysis of arterial spin labeling-based functional magnetic resonance imaging time series is presented in this article. The implementation uses a pseudo-continuous labeling scheme followed by a spiral k-space acquisition trajectory. Real-time reconstruction of the images, preprocessing, and regression analysis of the functional magnetic resonance imaging data were implemented on a laptop computer interfaced with the MRI scanner. The method allows the user to track the current raw data, subtraction images, and the cumulative t-statistic map overlaid on a cumulative subtraction image. The user is also able to track the time course of individual time courses and interactively selects a region of interest as a nuisance covariate. The pulse sequence allows the user to adjust acquisition and labeling parameters while observing their effect on the image within two successive pulse repetition times. This method is demonstrated by two functional imaging experiments: a simultaneous finger-tapping and visual stimulation paradigm, and a bimanual finger-tapping task. Magn Reson Med 65:1570-1577, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [1] Pseudo-continuous arterial spin labeling MRI study of schizophrenic patients
    Ota, Miho
    Ishikawa, Masanori
    Sato, Noriko
    Okazaki, Mitsutoshi
    Maikusa, Norihide
    Hori, Hiroaki
    Hattori, Kotaro
    Teraishi, Toshiya
    Ito, Kimiteru
    Kunugi, Hiroshi
    SCHIZOPHRENIA RESEARCH, 2014, 154 (1-3) : 113 - 118
  • [2] Estimation of Tagging Efficiency in Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI
    Jen, M.
    Yan, F.
    Tseng, Y.
    Lin, C.
    Chen, C.
    Liu, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3256 - 3257
  • [3] Superselective pseudo-continuous arterial spin labeling angiography
    Jensen-Kondering, Ulf
    Lindner, Thomas
    van Osch, Matthias J. P.
    Rohr, Axel
    Jansen, Olav
    Helle, Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1758 - 1767
  • [4] AN EXPERIMENTAL INVESTIGATION OF LABELING EFFICIENCY FOR PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING
    Chai, Yaqiong
    Bush, Adam
    Coloigner, Julie
    Qu, Xiaoping
    Chia, Jonathan
    Lepore, Natasha
    Wood, John
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1101 - 1104
  • [5] Optimisation of pulsed and pseudo-continuous arterial spin labeling MRI techniques: A phantom study
    Yusoff, Norain
    Zukhi, Jihan
    Rusli, Awatif
    Zainon, Rafidah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [6] Characterization of Skull Base Lesions Using Pseudo-Continuous Arterial Spin Labeling
    B. Geerts
    D. Leclercq
    S. Tezenas du Montcel
    B. Law-ye
    S. Gerber
    D. Bernardeschi
    D. Galanaud
    D. Dormont
    N. Pyatigorskaya
    Clinical Neuroradiology, 2019, 29 : 75 - 86
  • [7] Characterization of Skull Base Lesions Using Pseudo-Continuous Arterial Spin Labeling
    Geerts, B.
    Leclercq, D.
    du Montcel, S. Tezenas
    Law-ye, B.
    Gerber, S.
    Bernardeschi, D.
    Galanaud, D.
    Dormont, D.
    Pyatigorskaya, N.
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 75 - 86
  • [8] Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system
    Hernandez-Garcia, L
    Lee, GR
    Vazquez, AL
    Noll, DC
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 577 - 585
  • [9] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [10] Characterization of Pseudo-Continuous Arterial Spin Labeling: Simulations and Experimental Validation
    Lorenz, Kathrin
    Mildner, Toralf
    Schlumm, Torsten
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1638 - 1649