Volumetric modulated arc therapy (VMAT) comparison to 3D-conformal technique in lung stereotactic ablative radiotherapy (SABR)

被引:0
|
作者
Mark, Frances [1 ,2 ]
Alnsour, Anoud [3 ]
Penfold, Scott N. [4 ,5 ,6 ]
Esterman, Adrian
Keys, Robert [1 ]
Le, Hien [1 ,4 ,7 ]
机构
[1] Royal Adelaide Hosp, Dept Radiat Oncol, Adelaide, SA, Australia
[2] Plymouth Hosp Trust, Oncol Dept, Derriford Rd, Plymouth PL6 8DH, England
[3] King Hussein Canc Ctr KHCC, Amman, Jordan
[4] Australian Bragg Ctr Proton Therapy & Res, Adelaide, SA, Australia
[5] Univ Adelaide, Dept Phys, Adelaide, SA, Australia
[6] SAHMRI, Adelaide, SA, Australia
[7] Univ South Australia, Clin & Hlth Sci, Adelaide, SA, Australia
关键词
Non-small cell lung cancer; radiation pneumonitis; stereotactic ablative radiotherapy; V5; volumetric modulated arc therapy; BODY RADIATION-THERAPY; DOSIMETRIC PREDICTORS; CANCER PATIENTS; PNEUMONITIS; DELIVERY; OUTCOMES; SURGERY; TUMORS; SBRT;
D O I
10.1002/jmrs.634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionStereotactic ablative radiotherapy (SABR) can be a curative option for non-small cell lung cancer (NSCLC) and oligometastatic lung disease. Volumetric modulated arc therapy (VMAT) has offered further advancements in terms of radiation dose shaping without compromising treatment times however there is potential for greater low-dose exposure to the lung. This study was to assess whether VMAT lung SABR would result in any increase to the dosimetry parameters compared with three-dimensional conformal radiotherapy (3D-CRT) that could confer increased risk of radiation pneumonitis. MethodsA total of 53 and 30 3D-CRT treatment plans of patients treated with 48 Gy in 4 fractions were compared. ResultsNo statistically significant difference in planning target volumes between the VMAT 29.9 cc (range 12.4-58.5 cc) and 3D-CRT 31.2 cc (range 12.3-58.3 cc) P = 0.79. The mean of total lung V5, ipsilateral lung V5 and contralateral lung V5 all showed a trend of being smaller in the VMAT treatment group- 14% versus 15.8%, 25.6% versus 30.4% and 1.6% versus 2.2%, respectively, but all were not statistically significant differences. Mean of the mean lung dose MLD, again showed a trend of being lower in the VMAT treatments but was also non-significant, 2.6 Gy versus 3.0 Gy, P = 1.0. Mean V20 was the same in both cohorts, 3.3%. ConclusionsThe dosimetry for 3D-CRT and VMAT plans were not significantly different including V5, and therefore we conclude that VMAT treatment is unlikely to be associated with an increased risk of radiation pneumonitis.
引用
下载
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [41] VMAT-technique (volumetric modulated arc therapy) VS 3D-conformal radiation for 60 patients with Lymphomas in Radiation Oncology Department in Bank of Cyprus Oncology Center
    Theodorou, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S81 - S81
  • [42] Comparison of Breast Radiotherapy Induced Secondary Cancer Risk for 3D-Conformal Therapy, IMRT and VMAT
    Lee, B.
    Sung, J.
    Yoon, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Stereotactic Body Radiotherapy: Volumetric Modulated Arc Therapy Versus 3D Non-coplanar Conformal Radiotherapy for the Treatment of Early Stage Lung Cancer
    Herbert, C.
    Kwa, W.
    Nakano, S.
    James, K.
    Moiseenko, V.
    Wu, J.
    Schellenberg, D.
    Liu, M.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 511 - 516
  • [44] Intracranial Stereotactic Radiosurgery Treatment Planning Technique Comparison: Volumetric-Modulated Arc Therapy Vs. Dynamic Conformal Arc Therapy Or Static Field Intensity Modulated Radiotherapy
    Tseng, T.
    Sheu, R.
    Green, S.
    Lo, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2960 - 2960
  • [45] STEREOTACTIC ABLATIVE RADIOTHERAPY (SABR) OF CENTRALLY LOCATED EARLY STAGE LUNG CANCER ACCRUED TO RTOG 0813: NOVEL SCORING SYSTEM TO COMPARE PLAN QUALITY OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) VERSUS ROBOTIC RADIOSURGERY
    Nair, Vimoj J.
    Pantarotto, Jason
    Macrae, Robert
    Henderson, Elizabeth
    Wright, Gillian
    Mcmanus, Margaret
    Ciesielski, Margaret
    Lacelle, Manon
    Doody, Janice
    Szanto, Janos
    Ploquin, Nicholas
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S1131 - S1131
  • [46] COMPARISON OF TWO RADIOTHERAPY PLANNING TECHNIQUES FOR STAGE IIIA AND IIIB NSCLC: VOLUMETRIC MODULATED ARC THERAPY (VMAT) VS 3D CONFORMAL RADIOTHERAPY (3DCRT)
    Small, Katherine
    Unicomb, Kylie
    Hegi-Johnson, Fiona
    Van Tilburg, Kevin
    Yeghiaian-Alvandi, Roland
    Barber, Jeffrey
    White, Sean
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S844 - S844
  • [47] Stereotactic Ablative Radiotherapy (SABR) for low, intermediate and high risk prostate cancer using Volumetric Modulated Arc Therapy (VMAT) with a 10x Flattening Filter Free (FFF) beam
    Mestrovic, A.
    Fortin, D.
    Alexander, A.
    MEDICAL PHYSICS, 2014, 41 (08) : 29 - 29
  • [48] DOSIMETRIC COMPARISON OF INTENSITY-MODULATED RADIATION THERAPY, HELICAL TOMOTHERAPY, VOLUMETRIC MODULATED ARC THERAPY, AND 3D-CONFORMAL RADIOTHERAPY IN THE POST-OPERATIVE TREATMENT OF GASTRIC CANCER PATIENTS
    Loewen, S.
    Joseph, K.
    Usmani, N.
    Tankel, K.
    Severin, D.
    Nijjar, T.
    Warkentin, H.
    Syme, A.
    Williams, D.
    Field, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S36 - S37
  • [49] Dosimetric comparison of 3-dimensional conformal radiotherapy (3D-CRT) and volumetric-modulated arc therapy (VMAT) in locally advanced cancer cervix
    Agrawal, Animesh
    Hadi, Rahat
    Rath, Satyajeet
    Bharati, Avinav
    Rastogi, Madhup
    Khurana, Rohini
    Sahni, Kamal
    Sapru, Shantanu
    Gandhi, Ajeet Kumar
    Srivastava, Anoop Kumar
    Mishra, Surendra Prasad
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 60 - 67
  • [50] Radiobiological Comparison of Volumetric Modulated Arc Therapy, 3D Conformal Proton Therapy and Intensity Modulated Proton Therapy for Lung Cancer
    Sullivan, M.
    Jin, H.
    Ahmad, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E853 - E853