Volumetric modulated arc therapy (VMAT) comparison to 3D-conformal technique in lung stereotactic ablative radiotherapy (SABR)

被引:0
|
作者
Mark, Frances [1 ,2 ]
Alnsour, Anoud [3 ]
Penfold, Scott N. [4 ,5 ,6 ]
Esterman, Adrian
Keys, Robert [1 ]
Le, Hien [1 ,4 ,7 ]
机构
[1] Royal Adelaide Hosp, Dept Radiat Oncol, Adelaide, SA, Australia
[2] Plymouth Hosp Trust, Oncol Dept, Derriford Rd, Plymouth PL6 8DH, England
[3] King Hussein Canc Ctr KHCC, Amman, Jordan
[4] Australian Bragg Ctr Proton Therapy & Res, Adelaide, SA, Australia
[5] Univ Adelaide, Dept Phys, Adelaide, SA, Australia
[6] SAHMRI, Adelaide, SA, Australia
[7] Univ South Australia, Clin & Hlth Sci, Adelaide, SA, Australia
关键词
Non-small cell lung cancer; radiation pneumonitis; stereotactic ablative radiotherapy; V5; volumetric modulated arc therapy; BODY RADIATION-THERAPY; DOSIMETRIC PREDICTORS; CANCER PATIENTS; PNEUMONITIS; DELIVERY; OUTCOMES; SURGERY; TUMORS; SBRT;
D O I
10.1002/jmrs.634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionStereotactic ablative radiotherapy (SABR) can be a curative option for non-small cell lung cancer (NSCLC) and oligometastatic lung disease. Volumetric modulated arc therapy (VMAT) has offered further advancements in terms of radiation dose shaping without compromising treatment times however there is potential for greater low-dose exposure to the lung. This study was to assess whether VMAT lung SABR would result in any increase to the dosimetry parameters compared with three-dimensional conformal radiotherapy (3D-CRT) that could confer increased risk of radiation pneumonitis. MethodsA total of 53 and 30 3D-CRT treatment plans of patients treated with 48 Gy in 4 fractions were compared. ResultsNo statistically significant difference in planning target volumes between the VMAT 29.9 cc (range 12.4-58.5 cc) and 3D-CRT 31.2 cc (range 12.3-58.3 cc) P = 0.79. The mean of total lung V5, ipsilateral lung V5 and contralateral lung V5 all showed a trend of being smaller in the VMAT treatment group- 14% versus 15.8%, 25.6% versus 30.4% and 1.6% versus 2.2%, respectively, but all were not statistically significant differences. Mean of the mean lung dose MLD, again showed a trend of being lower in the VMAT treatments but was also non-significant, 2.6 Gy versus 3.0 Gy, P = 1.0. Mean V20 was the same in both cohorts, 3.3%. ConclusionsThe dosimetry for 3D-CRT and VMAT plans were not significantly different including V5, and therefore we conclude that VMAT treatment is unlikely to be associated with an increased risk of radiation pneumonitis.
引用
下载
收藏
页码:72 / 80
页数:9
相关论文
共 50 条
  • [21] STEREOTACTIC LUNG RADIOTHERAPY USING VOLUMETRIC MODULATED ARC THERAPY - A COMPARISON WITH CONVENTIONAL METHODS
    Ong, C. L.
    Verbakel, W.
    Senan, S.
    Cuijpers, J.
    Slotman, B.
    Lagerwaard, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S117
  • [22] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [23] Prostate Cancer Treatment-Related Toxicity: Comparison between 3D-Conformal Radiation Therapy (3D-CRT) and Volumetric Modulated Arc Therapy (VMAT) Techniques
    Tonetto, Fabrizio
    Magli, Alessandro
    Moretti, Eugenia
    Guerini, Andrea Emanuele
    Tullio, Annarita
    Reverberi, Chiara
    Ceschia, Tino
    Spiazzi, Luigi
    Titone, Francesca
    Prisco, Agnese
    Signor, Marco Andrea
    Buglione, Michela
    De Giorgi, Gioacchino
    Trovo, Marco
    Triggiani, Luca
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [24] Dosimetric Comparison between 3D-Conformal Radiotherapy and Intensity-modulated Radiation Therapy (IMRT) in Stereotactic Body Radiotherapy
    Cao, M.
    Das, I. J.
    Hutchins, K. M.
    Ewing, M. M.
    Fakiris, A. J.
    DesRosiers, C. M.
    Johnstone, P. A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S694 - S694
  • [25] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [26] Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment
    Bedford, James L.
    Fast, Martin F.
    Nil, Simeon
    McDonald, Fiona M. A.
    Ahmed, Merina
    Hansen, Vibeke N.
    Oelfke, Uwe
    RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) : 491 - 495
  • [27] Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy
    Gestaut, Matthew M.
    Thawani, Nitika
    Kim, Sangroh
    Gutti, Veera R.
    Jhavar, Sameer
    Deb, Niloyjyoti
    Morrow, Andrew
    Ward, Russell A.
    Huang, Jason H.
    Patel, Mehul
    JOURNAL OF NEURO-ONCOLOGY, 2017, 133 (01) : 165 - 172
  • [28] Single fraction spine stereotactic ablative body radiotherapy with volumetric modulated arc therapy
    Matthew M. Gestaut
    Nitika Thawani
    Sangroh Kim
    Veera R. Gutti
    Sameer Jhavar
    Niloyjyoti Deb
    Andrew Morrow
    Russell A. Ward
    Jason H. Huang
    Mehul Patel
    Journal of Neuro-Oncology, 2017, 133 : 165 - 172
  • [29] A Planning Comparison of 3D Conformal Multiple Static Field, Conformal Arc, and Volumetric Modulated Arc Therapy for the Delivery of Stereotactic Body Radiation Therapy for Lung Cancer
    Gabos, Z.
    Dickey, M. J.
    Drodge, S.
    Murray, B.
    Ghosh, S.
    Scrimger, R.
    Roa, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S901 - S901
  • [30] Spine Stereotactic Ablative Body Radiation Therapy (SABR) With Volumetric Modulated Arc Therapy (VMAT) for Vertebral Metastases With and Without Metastatic Spinal Cord Compression (MSCC)
    Gestaut, M. M.
    Thawani, N.
    Kim, S.
    Gutti, V. R.
    Morrow, A.
    Ward, R. A.
    Huang, J. H.
    Patel, M. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E517 - E518