The negative effect of natural convection in a vertical shell and tube latent heat energy storage unit

被引:0
|
作者
Wang, Leli [1 ,3 ]
Wang, Liangbi [2 ,3 ]
Wang, Ye [1 ,3 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Environm & Municipal Engn, Lanzhou 730070, Peoples R China
[2] Lanzhou Jiaotong Univ, Sch Mech Engn, Lanzhou 730070, Gansu, Peoples R China
[3] Lanzhou Jiaotong Univ, Key Lab Railway Vehicle Thermal Engn MOE, Lanzhou 730070, Gansu, Peoples R China
关键词
Coupling calculation; Charging process; Enthalpy method; Latent heat energy storage; Natural convection; Negative effect; PHASE-CHANGE; SYSTEM; SIMULATION;
D O I
10.1016/j.applthermaleng.2024.122688
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer in a latent heat energy storage unit is not intensive and is primarily determined by the low thermal diffusivity of phase change material. Then one may think even weak natural convection in the unit can significantly enhance heat transfer, and the role of natural convection in the unit is of great importance. It is very difficult to split out the role of natural convection from the experimental results. This paper investigates the role of natural convection in a vertically posited shell and tube latent heat energy storage unit by employing one model considering natural convection and the other model without considering natural convection. A critical vertical annular layer thickness and convection impact factor are proposed to determine the occurrence of natural convection and the effect of natural convection on the charging process. The results indicate that the critical vertical annular layer thickness to judge the occurrence of natural convection is 1.04 mm for the vertical unit analyzed in the present paper. The unit considering natural convection increases the time needed to complete the charging process by 46 % compared to the unit without considering natural convection, indicating that natural convection has negative effect on heat transfer, despite the gradual strengthening of natural convection in the vertical unit. The main reason is that natural convection brings phase change material with high temperature to region downstream the tube, resulting in a reduction of the temperature gradient on the tube wall downstream and the average heat flux normal to the tube surface. This might be indicated by that the convection impact factor is greater than 1 before 660 s, and is less than 1 after 660 s. The melting time increase caused by natural convection is respectively 39 %, 42 % and 46 % for win = 0.013, 0.13 and 0.28 m/s, and 46 %, 51 % and 60 % for theta f.in = 5, 10 and 20 K. This demonstrates that the negative effect of natural convection is even more noticeable at the higher flow velocities and inlet temperatures. But the existence of negative effect of the natural convection is independent of the heat transfer fluid inlet velocity and temperature.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] A comparative study on the performances of different shell-and-tube type latent heat thermal energy storage units including the effects of natural convection
    Han, Guang-Shun
    Ding, Hong-Sheng
    Huang, Yun
    Tong, Li-Ge
    Ding, Yu-Long
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 88 : 228 - 235
  • [32] Enhancing Heat Transfer and Energy Storage Performance of Shell-and-Tube Latent Heat Thermal Energy Storage Unit with Unequal-Length Fins
    Wu Yangyang
    Li Dong
    Yang Ruitong
    Muslum, Arici
    Liu Changyu
    [J]. JOURNAL OF THERMAL SCIENCE, 2023, 32 (06) : 2018 - 2031
  • [33] Enhancing Heat Transfer and Energy Storage Performance of Shell-and-Tube Latent Heat Thermal Energy Storage Unit with Unequal-Length Fins
    WU Yangyang
    LI Dong
    YANG Ruitong
    MüSLüM Arιcι
    LIU Changyu
    [J]. Journal of Thermal Science, 2023, 32 (06) : 2018 - 2031
  • [34] Experimental study on the melting and solidification behavior of erythritol in a vertical shell-and-tube latent heat thermal storage unit
    Wang, Yifei
    Wang, Liang
    Xie, Ningning
    Lin, Xipeng
    Chen, Haisheng
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 99 : 770 - 781
  • [35] Enhancing Heat Transfer and Energy Storage Performance of Shell-and-Tube Latent Heat Thermal Energy Storage Unit with Unequal-Length Fins
    Yangyang Wu
    Dong Li
    Ruitong Yang
    Arıcı Müslüm
    Changyu Liu
    [J]. Journal of Thermal Science, 2023, 32 : 2018 - 2031
  • [36] CFD Analysis of Concentric Tube in Tube Latent Heat Thermal Energy Storage Unit
    Shrivastava, Amit
    Kumar, Manvendra
    Kumar, Dileep
    Chakraborty, Prodyut R.
    [J]. PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [37] Heat transfer characteristics investigation of dual-PCM spiral coil tube latent heat thermal energy storage unit considering the effects of natural convection
    Zhang, Kun
    Yu, Zewen
    Wang, Junqing
    Song, Kewei
    Wang, Liangbi
    Shi, Guangtian
    [J]. Journal of Energy Storage, 2025, 107
  • [38] Thermal performance of a shell-and-tube latent heat thermal energy storage unit: Role of annular fins
    Yang, Xiaohu
    Lu, Zhao
    Bai, Qingsong
    Zhang, Qunli
    Jin, Liwen
    Yan, Jinyue
    [J]. APPLIED ENERGY, 2017, 202 : 558 - 570
  • [39] NUMERICAL-SIMULATION OF A SHELL-AND-TUBE LATENT-HEAT THERMAL-ENERGY STORAGE UNIT
    LACROIX, M
    [J]. SOLAR ENERGY, 1993, 50 (04) : 357 - 367
  • [40] Simplified model for estimating performance of latent heat thermal energy storage of a shell-and-tube type unit
    Nakaso, K
    Nogami, S
    Takahashi, N
    Hamada, Y
    Fukai, J
    [J]. KAGAKU KOGAKU RONBUNSHU, 2004, 30 (04) : 474 - 479