Therapeutic effect of a new implantation method of rotationally asymmetric multifocal intraocular lenses on visual quality

被引:1
|
作者
Wu, Xian [1 ,2 ]
Liu, Xiaomin [1 ,2 ]
Li, Dongfang [1 ,2 ]
Wang, Xiaoyun [1 ,2 ]
Huang, Yusen [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Shandong Eye Inst, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Angle kappa; Cataract surgery; Rotationally asymmetric multifocal intraocular lens; Visual quality; OPTICAL-PERFORMANCE; IOL; DECENTRATION; OUTCOMES; TILT;
D O I
10.1007/s10792-023-02862-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the visual quality after implantation of a rotationally asymmetric multifocal intraocular lens (IOL) using a new method according to the angle kappa.SettingQingdao Eye Hospital, Qingdao, China.DesignProspective case series.MethodsPatients with the implantation of SBL-3 IOLs for age-related cataract from September to December 2019 had the distance-horizontal zone of the IOL placed at the center of the optic axis using the Callisto Eye System. Postoperative visual acuities and defocus curves were recorded. Modulation transfer function cutoff frequency, Strehl ratio, and objective scatter index were measured using the Optical Quality Analysis System. The decentration and tilt of IOLs were analyzed by iTrace aberrometry and anterior segment optical coherence tomography. A questionnaire of patient satisfaction was also collected.ResultsThirty patients (60 eyes) were involved, with a balanced sex ratio. Their average age was 56.04 & PLUSMN; 10.83 years. The average angle kappa distance was 0.23 & PLUSMN; 0.121 mm. At 3 months after surgery, the mean uncorrected and corrected distance visual acuities were 0.01 & PLUSMN; 0.07 logMAR and 0.01 & PLUSMN; 0.06 logMAR. The uncorrected intermediate and near visual acuities were 0.09 & PLUSMN; 0.11 logMAR and 0.09 & PLUSMN; 0.11 logMAR. The mean horizontal and vertical tilts of IOLs were 0.67 & PLUSMN; 0.52 degrees and 0.47 & PLUSMN; 0.32 degrees. The mean decentration of IOLs was 0.17 & PLUSMN; 0.08 mm. Most patients were satisfied with their distance, intermediate, and near vision. There was mild glare in 58.3% of the eyes.ConclusionsLocating the center of the optic axis in the distance-horizontal zone during the implantation of SBL-3 IOLs could provide satisfactory visual acuity and quality.
引用
收藏
页码:4621 / 4629
页数:9
相关论文
共 50 条
  • [1] Therapeutic effect of a new implantation method of rotationally asymmetric multifocal intraocular lenses on visual quality
    Xian Wu
    Xiaomin Liu
    Dongfang Li
    Xiaoyun Wang
    Yusen Huang
    International Ophthalmology, 2023, 43 : 4621 - 4629
  • [2] A comparison of the visual performance of refractive rotationally asymmetric multifocal intraocular lenses and trifocal intraocular lenses
    Qiu, Jing-Jing
    Zhang, Qian
    Fu, Shu-Hua
    Huang, Jun-Qi
    Wang, Zhi-Hong
    You, Zhi-Peng
    Liu, Fei
    Sun, Tao
    MATERIALS EXPRESS, 2023, 13 (06) : 1110 - 1115
  • [3] Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses
    McNeely, Richard N.
    Pazo, Eric
    Spence, Andrew
    Richoz, Olivier
    Nesbit, M. Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08): : 1020 - 1026
  • [4] Visual Outcomes, Patient Satisfaction, and Light Distortion Analysis After Blended Implantation of Rotationally Asymmetric Multifocal Intraocular Lenses
    Vargas, Veronica
    Ferreira, Renan
    Alio del Barrio, Jorge L.
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) : 796 - +
  • [5] Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens
    Na Hui
    Mei-Fang Chu
    Yan Li
    Cong-Yi Wang
    Lei Yu
    Bo Ma
    International Journal of Ophthalmology, 2022, (09) : 1460 - 1467
  • [6] Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens
    Hui, Na
    Chu, Mei-Fang
    Li, Yan
    Wang, Cong-Yi
    Yu, Lei
    Ma, Bo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (09) : 1460 - 1467
  • [7] Rotationally asymmetric multifocal intraocular lenses: preoperative considerations and postoperative outcomes
    Moore, Jonathan E.
    McNeely, Richard N.
    Pazo, Eric E.
    Moore, Tara C. B.
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (01) : 9 - 15
  • [8] Influence of angle kappa-customized implantation of rotationally asymmetric multifocal intraocular lens on visual quality and patient satisfaction
    Liu, Yiyun
    Gao, Yufei
    Liu, Rongjun
    Hu, Chenxi
    Ma, Baikai
    Miao, Jinhong
    Luo, Jinhua
    Qi, Hong
    ACTA OPHTHALMOLOGICA, 2020, 98 (06) : E734 - E742
  • [9] Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens
    Wang, Xiao
    Tu, Haixia
    Wang, Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [10] Rotationally asymmetric multifocal intraocular lens
    Carifi, Gianluca
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1116 - 1117