Therapeutic effect of a new implantation method of rotationally asymmetric multifocal intraocular lenses on visual quality

被引:1
|
作者
Wu, Xian [1 ,2 ]
Liu, Xiaomin [1 ,2 ]
Li, Dongfang [1 ,2 ]
Wang, Xiaoyun [1 ,2 ]
Huang, Yusen [1 ,2 ]
机构
[1] Shandong First Med Univ, Qingdao Eye Hosp, Qingdao, Peoples R China
[2] Shandong First Med Univ, Shandong Eye Inst, State Key Lab Cultivat Base, Shandong Prov Key Lab Ophthalmol, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Angle kappa; Cataract surgery; Rotationally asymmetric multifocal intraocular lens; Visual quality; OPTICAL-PERFORMANCE; IOL; DECENTRATION; OUTCOMES; TILT;
D O I
10.1007/s10792-023-02862-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo assess the visual quality after implantation of a rotationally asymmetric multifocal intraocular lens (IOL) using a new method according to the angle kappa.SettingQingdao Eye Hospital, Qingdao, China.DesignProspective case series.MethodsPatients with the implantation of SBL-3 IOLs for age-related cataract from September to December 2019 had the distance-horizontal zone of the IOL placed at the center of the optic axis using the Callisto Eye System. Postoperative visual acuities and defocus curves were recorded. Modulation transfer function cutoff frequency, Strehl ratio, and objective scatter index were measured using the Optical Quality Analysis System. The decentration and tilt of IOLs were analyzed by iTrace aberrometry and anterior segment optical coherence tomography. A questionnaire of patient satisfaction was also collected.ResultsThirty patients (60 eyes) were involved, with a balanced sex ratio. Their average age was 56.04 & PLUSMN; 10.83 years. The average angle kappa distance was 0.23 & PLUSMN; 0.121 mm. At 3 months after surgery, the mean uncorrected and corrected distance visual acuities were 0.01 & PLUSMN; 0.07 logMAR and 0.01 & PLUSMN; 0.06 logMAR. The uncorrected intermediate and near visual acuities were 0.09 & PLUSMN; 0.11 logMAR and 0.09 & PLUSMN; 0.11 logMAR. The mean horizontal and vertical tilts of IOLs were 0.67 & PLUSMN; 0.52 degrees and 0.47 & PLUSMN; 0.32 degrees. The mean decentration of IOLs was 0.17 & PLUSMN; 0.08 mm. Most patients were satisfied with their distance, intermediate, and near vision. There was mild glare in 58.3% of the eyes.ConclusionsLocating the center of the optic axis in the distance-horizontal zone during the implantation of SBL-3 IOLs could provide satisfactory visual acuity and quality.
引用
收藏
页码:4621 / 4629
页数:9
相关论文
共 50 条
  • [21] Orientation of the intermediate-vision zone of rotationally asymmetric multifocal intraocular lenses and photic phenomena
    Mito, Tsuyoshi
    Ukai, Yuki
    Nakatsugawa, Yui
    Shibata, Teppei
    Shibata, Shinsuke
    Kubo, Eri
    Sasaki, Hiroshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2023, 67 (03) : 318 - 325
  • [22] Orientation of the intermediate-vision zone of rotationally asymmetric multifocal intraocular lenses and photic phenomena
    Tsuyoshi Mito
    Yuki Ukai
    Yui Nakatsugawa
    Teppei Shibata
    Shinsuke Shibata
    Eri Kubo
    Hiroshi Sasaki
    Japanese Journal of Ophthalmology, 2023, 67 : 318 - 325
  • [23] Correlation of Visual Performance With Quality of Life and Intraocular Aberrometric Profile in Patients Implanted With Rotationally Asymmetric Multifocal IOLs
    Ramon, Maria L.
    Pinero, David P.
    Perez-Cambrodi, Rafael J.
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) : 93 - U
  • [24] Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses
    McNeely, Richard N.
    Pazo, Eric
    Spence, Andrew
    Richoz, Olivier
    Nesbit, M. Andrew
    Moore, Tara C. B.
    Moore, Jonathan E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1721 - 1729
  • [25] Near visual acuity after implantation of monofocal versus multifocal intraocular lenses
    Dick, HB
    Krist, R
    Schwenn, O
    Pfeiffer, N
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (06) : 406 - 411
  • [26] Dissatisfaction after implantation of multifocal intraocular lenses
    Bonnet, Clemence
    Brezin, Antoine P.
    Monnet, Dominique
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [27] Dissatisfaction after implantation of multifocal intraocular lenses
    de Vries, Niels E.
    Webers, Carroll A. B.
    Touwslager, Wouter R. H.
    Bauer, Noel J. C.
    de Brabander, John
    Berendschot, Tos T.
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05): : 859 - 865
  • [28] Lens Surgery: Implantation of Multifocal Intraocular Lenses
    Shajari, Mehdi
    Mayer, Wolfgang J.
    Priglinger, Siegfried
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (12) : 1461 - 1469
  • [29] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Özge Güngör Akkuş
    Ikbal Seza Petriçli
    International Ophthalmology, 2018, 38 : 1011 - 1019
  • [30] Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
    Akkus, Ozge Gungor
    Petricli, Ikbal Seza
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (03) : 1011 - 1019