ObjectivesThe goal was to investigate the relationship between the insertion angle/cochlear coverage of cochlear implant electrode arrays and post-operative speech recognition scores in a large cohort of patients implanted with lateral wall electrode arrays. MethodsPre- and post-operative cone beam computed tomography scans of 154 ears implanted with lateral wall electrode arrays were evaluated. Traces of lateral wall and electrode arrays were combined into a virtual reconstruction of the implanted cochlea. This reconstruction was used to measure insertion angles and proportional cochlear coverage. Word recognition scores and sentence recognition scores measured 12 months after implantation using electric-only stimulation were used to examine the relationship between cochlear coverage/insertion angle and implantation outcomes. ResultsPost-operative word recognition scores and the difference between post- and pre-operative word recognition scores were positively correlated with both cochlear coverage and insertion angle, however sentence recognition scores were not. A group-wise comparison of word recognition scores revealed that patients with cochlear coverage below 70% performed significantly worse than patients with coverage between 79%-82% (p = 0.003). Performance of patients with coverage above 82% was on average poorer than between 79%-82, although this finding was not statistically significant (p = 0.84). Dividing the cohort into groups based on insertion angle quadrants revealed that word recognition scores were highest above 450 & DEG; insertion angle, sentence recognition scores were highest between 450 & DEG; and 630 & DEG; and the difference between pre- and post-operative word recognition scores was largest between 540 & DEG; and 630 & DEG;, however none of these differences reached statistical significance. ConclusionsThe results of this study show that cochlear coverage has an effect on post-operative word recognition abilities and the benefit patients receive from their implant. Generally, higher coverage led to better outcomes, however there were results indicating that insertion past 82% cochlear coverage may not provide an additional benefit for word recognition. These findings can be useful for choosing the optimal electrode array and thereby improving cochlear implantation outcomes on a patient-individual basis.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Three dimensional image of the inner ear for pre- & post-operative evaluation of cochlear implant
    Seto, Y.
    Kobayashi, M.
    Seto, A.
    Yasuda, M.
    Muramatsu, H.
    Edamatsu, H.
    Proceedings of the 5th Asia Pacific Symposium on Cochlear Implant and Related Sciences, 2005, : 37 - 39
  • [42] Deep Learning Based Metal Artifacts Reduction in Post-operative Cochlear Implant CT Imaging
    Wang, Zihao
    Vandersteen, Clair
    Demarcy, Thomas
    Gnansia, Dan
    Raffaelli, Charles
    Guevara, Nicolas
    Delingette, Herve
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT VI, 2019, 11769 : 121 - 129
  • [43] Development and Characterizaion of a Micromagnetic Alternative to Cochlear Implant Electrode Arrays
    Sarreal, Ressa Reneth S.
    Blake, David T.
    Bhatti, Pamela T.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 2116 - 2125
  • [44] Speech Perception Outcomes for Adult Cochlear Implant Recipients Using a Lateral Wall or Perimodiolar Array
    Moran, Michelle
    Vandali, Andrew
    Briggs, Robert J. S.
    Dettman, Shani
    Cowan, Robert S. C.
    Dowell, Richard C.
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 608 - 616
  • [45] Comparison of Speech Recognition in Cochlear Implant Users with Different Speech Processors
    Canina Pinheiro, Maria Madalena
    Mancini, Patricia Cotta
    Soares, Alexandra Dezani
    Ribas, Angela
    Lima, Danielle Penna
    Cavadas, Marcia
    Banhara, Marcos Roberto
    da Silva Carvalho, Sirley Alves
    Buzo, Byanka Cagnacci
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2021, 32 (07) : 469 - 476
  • [46] Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems
    Firszt, JB
    Holden, LK
    Skinner, MW
    Tobey, EA
    Peterson, A
    Gaggl, W
    Runge-Samuelson, CL
    Wackym, PA
    EAR AND HEARING, 2004, 25 (04): : 375 - 387
  • [47] Electrode impedances in children with cochlear implants: Comparison between intra-operative Switch ON and post-operative Switch ON
    Meghanadh, K. R.
    Saxena, Udit
    Kumar, S. B. Rathna
    Chacko, Gish
    Vikas, N.
    Sandhra, S.
    Mehta, Gunjan
    COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (02) : 65 - 72
  • [48] Gentamicin affects connexin 26 expression in the cochlear lateral wall
    Hu, P.
    Lai, R.
    Xie, D.
    B-ENT, 2012, 8 (02): : 77 - 84
  • [49] Factors influencing the relationship between cochlear health measures and speech recognition in cochlear implant users
    Zamaninezhad, Ladan
    Mert, Berkutay
    Benav, Heval
    Tillein, Jochen
    Garnham, Carolyn
    Baumann, Uwe
    FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2023, 17
  • [50] Electrode Interaction in Cochlear Implant Recipients: Comparison of Straight and Contour Electrode Arrays
    Xi, Xin
    Ji, Fei
    Han, Dongyi
    Hong, Mengdi
    Chen, Aiting
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2009, 71 (04): : 228 - 237