ObjectivesThe goal was to investigate the relationship between the insertion angle/cochlear coverage of cochlear implant electrode arrays and post-operative speech recognition scores in a large cohort of patients implanted with lateral wall electrode arrays. MethodsPre- and post-operative cone beam computed tomography scans of 154 ears implanted with lateral wall electrode arrays were evaluated. Traces of lateral wall and electrode arrays were combined into a virtual reconstruction of the implanted cochlea. This reconstruction was used to measure insertion angles and proportional cochlear coverage. Word recognition scores and sentence recognition scores measured 12 months after implantation using electric-only stimulation were used to examine the relationship between cochlear coverage/insertion angle and implantation outcomes. ResultsPost-operative word recognition scores and the difference between post- and pre-operative word recognition scores were positively correlated with both cochlear coverage and insertion angle, however sentence recognition scores were not. A group-wise comparison of word recognition scores revealed that patients with cochlear coverage below 70% performed significantly worse than patients with coverage between 79%-82% (p = 0.003). Performance of patients with coverage above 82% was on average poorer than between 79%-82, although this finding was not statistically significant (p = 0.84). Dividing the cohort into groups based on insertion angle quadrants revealed that word recognition scores were highest above 450 & DEG; insertion angle, sentence recognition scores were highest between 450 & DEG; and 630 & DEG; and the difference between pre- and post-operative word recognition scores was largest between 540 & DEG; and 630 & DEG;, however none of these differences reached statistical significance. ConclusionsThe results of this study show that cochlear coverage has an effect on post-operative word recognition abilities and the benefit patients receive from their implant. Generally, higher coverage led to better outcomes, however there were results indicating that insertion past 82% cochlear coverage may not provide an additional benefit for word recognition. These findings can be useful for choosing the optimal electrode array and thereby improving cochlear implantation outcomes on a patient-individual basis.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Intensity Discrimination and Speech Recognition of Cochlear Implant Users
    Colette M. McKay
    Natalie Rickard
    Katherine Henshall
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 589 - 600
  • [32] Intensity Discrimination and Speech Recognition of Cochlear Implant Users
    McKay, Colette M.
    Rickard, Natalie
    Henshall, Katherine
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (05): : 589 - 600
  • [33] Psychophysical metrics and speech recognition in cochlear implant users
    Pfingst, BE
    Xu, L
    AUDIOLOGY AND NEURO-OTOLOGY, 2005, 10 (06) : 331 - 341
  • [34] Temporal processing and speech recognition in cochlear implant users
    Fu, QJ
    NEUROREPORT, 2002, 13 (13) : 1635 - 1639
  • [35] Channel weights for speech recognition in cochlear implant users
    Mehr, MA
    Turner, CW
    Parkinson, A
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 109 (01): : 359 - 366
  • [36] Speech recognition in background noise of cochlear implant patients
    Fetterman, BL
    Domico, EH
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2002, 126 (03) : 257 - 263
  • [37] On the Intracochlear Location of Straight Electrode Arrays After Cochlear Implantation: How Lateral Are Lateral Wall Electrodes?
    Salcher, Rolf
    Boruchov, Aaron
    Timm, Max
    Steffens, Melanie
    Giesemann, Anja
    Lenarz, Thomas
    Warnecke, Athanasia
    OTOLOGY & NEUROTOLOGY, 2021, 42 (02) : 242 - 250
  • [38] Impact of Cochlear Implant Electrode Array Design on Post-Op Speech Perception
    Pennington-FitzGerald, William
    Waring, Nicholas A.
    Hamiter, Mickie
    Kuhlmey, Megan
    Kim, Ana H.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2025, 172 (03) : 960 - 966
  • [39] An In-Vitro Insertion-Force Study of Magnetically Guided Lateral-Wall Cochlear-Implant Electrode Arrays
    Leon, Lisandro
    Warren, Frank M.
    Abbott, Jake J.
    OTOLOGY & NEUROTOLOGY, 2018, 39 (02) : e63 - e73
  • [40] Pre- and post-operative dizziness, tinnitus, and taste disturbances among cochlear implant recipients
    Mikkelsen, K. S.
    Ovesen, T.
    Swan, C. Z.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2017, 131 (04): : 309 - 315