Sulfur dots/Au@Ag nanorods array-based polarized ECL sensor for the detection of thyroid cancer biomarker

被引:4
|
作者
Ding, Zixuan [1 ,2 ]
Wang, Peilin [1 ]
Li, Zhenrun [1 ]
Guo, Yupeng
Ma, Qiang [1 ,2 ]
机构
[1] Jilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Peoples R China
[2] Jilin Univ, Natl Chem Expt Teaching Demonstrat Ctr, Changchun 130012, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemiluminescence; Surface plasma coupling; Nanorod array structure; Sulfur dots; Thyroid cancer diagnosis; ENHANCED ELECTROCHEMILUMINESCENCE; GOLD NANOPARTICLES; BRAF; REDUCTION; MUTATION;
D O I
10.1016/j.talanta.2023.124925
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of highly sensitive electrochemiluminescence (ECL) techniques with localized surface plasmon resonance (LSPR) effect can achieve the highly sensitive and specific detection in the analytical and biosensing applications. However, how to effectively improve the electromagnetic field intensity is an unresolved issue. Herein, we have developed an ECL biosensor based on sulfur dots and Au@Ag nanorod array architecture. Firstly, the high luminescent sulfur dots with ionic liquid capping (S dots (IL) have been prepared as the new ECL emitter. The ionic liquid greatly improved the conductivity of sulfur dots in the sensing process. Furthermore, Au@Ag nanorods array structure was constructed on the electrode surface by the evaporation induced selfassembly. On the one hand, the LSPR of Au@Ag nanorods was more significant than that of good nanomaterial due to the plasma hybridization and the competition between free electrons and oscillating electrons. On the other hand, nanorods array structure had strong electromagnetic field intensity as hot spots due to the surface plasmon coupling ECL effect (SPC-ECL) effect. Therefore, the Au @Ag nanorods array architecture not only greatly enhanced the ECL intensity of sulfur dots, but also changed the ECL signals into polarized emission. Finally, the constructed polarized ECL sensing system was used to detect the mutated BRAF DNA in the eluent of thyroid tumor tissue. The biosensor showed the linear range from 100 fM to 10 nM with a detection limit of 20 fM. The satisfactory results demonstrated that the developed sensing strategy had great potential in the clinical diagnosis of BRAF DNA mutation in thyroid cancer.
引用
收藏
页数:8
相关论文
共 41 条
  • [31] Sub-ppt level voltammetric sensor for Hg2+ detection based on nafion stabilized l-cysteine-capped Au@Ag core-shell nanoparticles
    Siddiqui, Samia
    Nafady, Ayman
    El-Sagher, Hussein M.
    Al-Saeedi, Sameerah, I
    Alsalme, Ali M.
    Sirajuddin
    Talpur, Farah N.
    Sherazi, Syed Tufail H.
    Kalhoro, Muhammad S.
    Shah, Muhammad R.
    Shaikh, Tayyaba
    Arain, Munazza
    Bhargava, Suresh K.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2019, 23 (07) : 2073 - 2083
  • [32] Highly sensitive electrochemical sensor based on environmentally friendly biomass-derived sulfur-doped graphene for cancer biomarker detection
    Shahzad, Faisal
    Zaidi, Shabi Abbas
    Koo, Chong Min
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 716 - 724
  • [33] Sub-ppt level voltammetric sensor for Hg2+ detection based on nafion stabilized l-cysteine-capped Au@Ag core-shell nanoparticles
    Samia Siddiqui
    Ayman Nafady
    Hussein M. El-Sagher
    Sameerah I. Al-Saeedi
    Ali M. Alsalme
    Farah N. Sirajuddin
    Syed Tufail H. Talpur
    Muhammad S. Sherazi
    Muhammad R. Kalhoro
    Tayyaba Shah
    Munazza Shaikh
    Suresh K. Arain
    Journal of Solid State Electrochemistry, 2019, 23 : 2073 - 2083
  • [34] Smartphone-integrated colorimetric sensor array-based reader system and fluorometric detection of dopamine in male and female geriatric plasma by bluish-green fluorescent carbon quantum dots
    Chellasamy, Gayathri
    Ankireddy, Seshadri Reddy
    Lee, Kook-Nyung
    Govindaraju, Saravanan
    Yun, Kyusik
    MATERIALS TODAY BIO, 2021, 12
  • [35] Detection of Skin, Cervical, and Breast Cancer Using Au-Ag Alloy and WS2-Based Surface Plasmon Resonance Sensor
    Karki, Bhishma
    Alsubaie, Abdullah Saad
    Sarkar, Partha
    Sharma, Manoj
    Ali, Naim Ben
    PLASMONICS, 2024,
  • [36] Rapid, quantitative and ultra-sensitive detection of cancer biomarker by a SERRS-based lateral flow immunoassay using bovine serum albumin coated Au nanorods
    Lu, Luchun
    Yu, Jiangliu
    Liu, Xiaoxian
    Yang, Xingsheng
    Zhou, Zihui
    Jin, Qing
    Xiao, Rui
    Wang, Chongwen
    RSC ADVANCES, 2020, 10 (01) : 271 - 281
  • [37] A microfluidic chip using Au@SiO2 array-based highly SERS-active substrates for ultrasensitive detection of dual cervical cancer-related biomarkers
    Gu, Yingyan
    Li, Zhiyue
    Ge, Shengjie
    Mao, Yu
    Gu, Yuexing
    Cao, Xiaowei
    Lu, Dan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (26) : 7659 - 7673
  • [38] SERS Immunosensor Based on High-Density "Hotspots" Au©SiO2 Array Substrate and Au-Ag Nanoshells Probes for Ultrasensitive Detection of Dual Biomarkers in the Cervical Cancer Serum
    Ran, Menglin
    Song, Qilong
    Liu, Yifan
    Sun, Yue
    Cao, Xiaowei
    Lu, Dan
    NANO, 2022, 17 (03)
  • [39] High electrochemical active Au-NP/2D zinc-metal organic frameworks heterostructure-based ECL sensor for the miRNA-522 detection in triple negative breast cancer
    Zhong, Weiyao
    Zhang, Yang
    Zhao, He
    Liang, Zihui
    Shi, Jingwei
    Ma, Qiang
    TALANTA, 2023, 265
  • [40] A SERS microfluidic chip based on hpDNA-functioned Au-Ag nanobowl array for efficient simultaneous detection of non-small cell lung cancer-related microRNAs
    Gu, Yuexing
    Cao, Dawei
    Mao, Yu
    Ge, Shengjie
    Li, Zhiyue
    Gu, Yingyan
    Sun, Yue
    Li, Li
    Cao, Xiaowei
    MICROCHEMICAL JOURNAL, 2022, 182