Application of net zero extended exergy buildings concept for sustainable buildings analysis

被引:2
|
作者
Acikkalp, Emin [1 ]
Hepbasli, Arif [2 ]
Palmero-Marrero, Ana I. [3 ]
Borge-Diez, David [4 ]
机构
[1] Eskisehir Tech Univ, Fac Engn, Dept Mech Engn, Iki Eylul Campus, TR-26555 Eskisehir, Turkiye
[2] Yasar Univ, Fac Engn, Dept Energy Syst Engn, TR-35100 Izmir, Turkiye
[3] Univ Porto, Inst Sci & Innovat Mech & Ind Engn INEGI, FEUP, R Dr Roberto Frias 400, P-4200465 Porto, Portugal
[4] Univ Leon, Dept Elect Engn Syst & Automat, Leon 24008, Spain
来源
关键词
Net-zero energy building; Exergy; Extended exergy; Net-zero extended exergy; Exergetic footprint; PRIMARY ENERGY TRANSFORMATION; EFFICIENCY;
D O I
10.1016/j.jobe.2023.106095
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Different Zero-Energy Building (ZEB)-related definitions considering its four main dimensions, such as zero energy, zero carbon, zero exergy and zero cost, have been proposed by different investigators. Among these, exergy-based definitions are relatively low in numbers. In this regard, the main objective of this present study is to propose net zero extended exergy buildings as a new concept, which combines extended exergy and net zero exergy building concepts and is a measure of the exergetic footprint. This concept setups a balance between extended exergy accounting of electricity from the grid and electricity generated in building. The proposed methodology is applied to a building available in the literature for heating and cooling seasons. Results show that 450Wp peak power and 44.181 kWh electrical energy must be obtained for meeting the electricity demand of the building. Another novel result is that the extended exergy accounting of the electricity generated by PV panels is bigger than the extended exergy of the electricity taken from the gird meaning that exergetic footprint of the electricity generated by PV panels is bigger. However, this result must be interpreted for the whole life time of the system.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [21] Application of sensitivity analysis in design of sustainable buildings
    Heiselberg, Per
    Brohus, Henrik
    Hesselholt, Allan
    Rasmussen, Henrik
    Seinre, Erkki
    Thomas, Sara
    RENEWABLE ENERGY, 2009, 34 (09) : 2030 - 2036
  • [22] THE CONCEPT MODEL OF SUSTAINABLE BUILDINGS REFURBISHMENT
    Mickaityte, Aiste
    Zavadskas, Edmundas K.
    Kaklauskas, Arturas
    Tupenaite, Laura
    INTERNATIONAL JOURNAL OF STRATEGIC PROPERTY MANAGEMENT, 2008, 12 (01) : 53 - 68
  • [23] An exergy aware optimization and control algorithm for sustainable buildings
    Kilkis, BI
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2004, 1 (01) : 65 - 77
  • [24] Net Zero Energy Buildings: Expense or Investment?
    Adhikari, R. S.
    Aste, N.
    Del Pero, C.
    Manfren, M.
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1331 - 1336
  • [25] NET-ZERO BUILDINGS: THE FUTURE OF CONSTRUCTION?
    Williams L.
    Engineering and Technology, 2022, 17 (11): : 60 - 63
  • [26] BUILDINGS ALIVE! ESTABLISHING THE COST OF LIVING BUILDINGS STRIVING FOR NET ZERO PERFORMANCE
    Heider, Elizabeth J.
    Brockman, Clark
    JOURNAL OF GREEN BUILDING, 2009, 4 (03): : 61 - 71
  • [27] Opportunities and Challenges with Net Zero Energy Buildings
    Mukherjee, Satyen
    2011 IEEE 23RD INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS (ISPSD), 2011, : 1 - 5
  • [28] Embodied carbon emissions of buildings: Taking a step towards net zero buildings
    Myint, Nwe Ni
    Shafique, Muhammad
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [29] The feasibility of large net zero energy buildings
    Hall, Monika
    Geissler, Achim
    BAUPHYSIK, 2016, 38 (01) : 38 - 49
  • [30] Recent progress on net zero energy buildings
    Kapsalaki, Maria
    Leal, Vitor
    ADVANCES IN BUILDING ENERGY RESEARCH, 2011, 5 (01) : 129 - 162