Dynamic Changes of Capsular-Intraocular Lens Adhesion in Plate-Haptic Hydrophilic and Loop-Haptic Hydrophobic Eyes

被引:0
|
作者
Zhao, Yinying [1 ,2 ]
Zhang, Zhewen [1 ,2 ]
Yang, Fuman [1 ,2 ]
Chang, Pingjun [1 ,2 ]
Wang, Dandan [1 ,2 ]
Huang, Feng [1 ,2 ]
Zhao, Yune [1 ,2 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, 618 East Feng Qi Rd, Hangzhou 310000, Zhejiang, Peoples R China
[2] Natl Clin Res Ctr Ocular Dis, Wenzhou, Zhejiang, Peoples R China
关键词
Intraocular lens; Capsular adhesion; Plate-haptic; Loop-haptic; OPTIC EDGE DESIGN; POSTERIOR CAPSULE; QUANTITATIVE-ANALYSIS; ROTATIONAL STABILITY; OPACIFICATION; SILICONE;
D O I
10.1007/s40123-024-00933-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction The aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes.Methods Cataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively.Results In total, 66 eyes of 66 patients were eligible for the analysis: 33 in the plate-haptic group and 33 in the loop-haptic group. The contact between the anterior capsule and IOL in the plate-haptic group was earlier than that in the loop-haptic group upon comparing the measurements taken at 1 day and 1 week (p = 0.001, p = 0.003, respectively). The complete attachment of the posterior capsule and IOL in the plate-haptic group was significantly greater at 1 week, 1 month, and 3 months (p = 0.001, p = 0.000, p = 0.001, respectively). The capsular bend index of the plate-haptic group was significantly greater than that of the loop-haptic group at each time points except at 1 day (p = 0.007, p = 0.049, p = 0.005, respectively). Furthermore, a new type of capsular bend, "cocked adhesion," was observed in the plate-haptic eyes.Conclusions The plate-haptic IOL demonstrated excellent capsular adhesion compared to the loop-haptic IOL, which was probably attributed to haptic compressibility. A special cocked configuration of the capsular bend in plate-haptic IOL was observed for the first time. Further studies are warranted to confirm the effect of the new type of capsular bend.
引用
收藏
页码:1527 / 1535
页数:9
相关论文
共 44 条
  • [31] Optical coherence tomography of intraocular lens implants and their relationship to the posterior capsule: A pilot study comparing a hydrophobic acrylic to a plate-haptic silicone type
    Elgohary, MA
    Chauhan, DS
    Dowler, JG
    OPHTHALMIC RESEARCH, 2006, 38 (03) : 116 - 124
  • [32] Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of + 1.5 diopters
    Tetsuro Oshika
    Kazuno Negishi
    Toru Noda
    Hiroyuki Arai
    Mikio Inamura
    Yasushi Inoue
    Teruyuki Miyoshi
    Yoshifumi Fujita
    Kazunori Miyata
    Yumi Hasegawa
    BMC Ophthalmology, 20
  • [33] Postoperative intraocular lens rotation -: A randomized comparison of plate and loop haptic implants -: Discussion
    Apple, DJ
    OPHTHALMOLOGY, 1999, 106 (11) : 2196 - 2196
  • [34] Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of+1.5 diopters
    Oshika, Tetsuro
    Negishi, Kazuno
    Noda, Toru
    Arai, Hiroyuki
    Inamura, Mikio
    Inoue, Yasushi
    Miyoshi, Teruyuki
    Fujita, Yoshifumi
    Miyata, Kazunori
    Hasegawa, Yumi
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [35] Capsular bag stability and posterior capsule opacification of a plate-haptic design microincision cataract surgery intraocular lens: 3-year results of a randomised trial
    Hirnschall, Nino
    Nishi, Yutaro
    Crnej, Alja
    Koshy, John
    Gangwani, Vinod
    Maurino, Vincenzo
    Findl, Oliver
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) : 1565 - 1568
  • [36] Four-Point Flange Intrascleral Fixation With Double Suture Through the Dislocated Plate-Haptic Trifocal Intraocular Lens
    Wang, Yong
    Zhou, Li
    Bao, Xianyi
    Peng, Tingting
    Lei, Rong
    Ortega-usobiaga, Julio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 255 : 68 - 73
  • [37] Transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens in aphakic nonvitrectomized eyes
    Agrawal, Siddharth
    Singh, Vinita
    Gupta, Sanjiv Kumar
    Misra, Nibha
    Srivastava, Rajat M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (08) : 649 - 653
  • [38] Matched comparison of rotational stability of 1-piece acrylic and plate-haptic silicone toric intraocular lenses in Asian eyes
    Chua, Wei-Han
    Yuen, Leonard H.
    Chua, Jocelyn
    Teh, Gillian
    Hill, Warren E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 620 - 624
  • [39] A SHORT HAPTIC DIAMETER MODIFIED J-LOOP INTRAOCULAR-LENS FOR IMPROVED CAPSULAR BAG PERFORMANCE
    DAVISON, JA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (02): : 161 - 166
  • [40] LONG-TERM RESULTS AFTER THE IMPLANTATION OF A PLATE HAPTIC SILICONE INTRAOCULAR-LENS IN THE CAPSULAR BAG
    ZEHETMAYER, M
    SKORPIK, C
    WEGHAUPT, H
    PFLEGER, T
    SCHOLZ, U
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1994, 204 (04) : 220 - 225