Dynamic Changes of Capsular-Intraocular Lens Adhesion in Plate-Haptic Hydrophilic and Loop-Haptic Hydrophobic Eyes

被引:0
|
作者
Zhao, Yinying [1 ,2 ]
Zhang, Zhewen [1 ,2 ]
Yang, Fuman [1 ,2 ]
Chang, Pingjun [1 ,2 ]
Wang, Dandan [1 ,2 ]
Huang, Feng [1 ,2 ]
Zhao, Yune [1 ,2 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, 618 East Feng Qi Rd, Hangzhou 310000, Zhejiang, Peoples R China
[2] Natl Clin Res Ctr Ocular Dis, Wenzhou, Zhejiang, Peoples R China
关键词
Intraocular lens; Capsular adhesion; Plate-haptic; Loop-haptic; OPTIC EDGE DESIGN; POSTERIOR CAPSULE; QUANTITATIVE-ANALYSIS; ROTATIONAL STABILITY; OPACIFICATION; SILICONE;
D O I
10.1007/s40123-024-00933-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction The aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes.Methods Cataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively.Results In total, 66 eyes of 66 patients were eligible for the analysis: 33 in the plate-haptic group and 33 in the loop-haptic group. The contact between the anterior capsule and IOL in the plate-haptic group was earlier than that in the loop-haptic group upon comparing the measurements taken at 1 day and 1 week (p = 0.001, p = 0.003, respectively). The complete attachment of the posterior capsule and IOL in the plate-haptic group was significantly greater at 1 week, 1 month, and 3 months (p = 0.001, p = 0.000, p = 0.001, respectively). The capsular bend index of the plate-haptic group was significantly greater than that of the loop-haptic group at each time points except at 1 day (p = 0.007, p = 0.049, p = 0.005, respectively). Furthermore, a new type of capsular bend, "cocked adhesion," was observed in the plate-haptic eyes.Conclusions The plate-haptic IOL demonstrated excellent capsular adhesion compared to the loop-haptic IOL, which was probably attributed to haptic compressibility. A special cocked configuration of the capsular bend in plate-haptic IOL was observed for the first time. Further studies are warranted to confirm the effect of the new type of capsular bend.
引用
收藏
页码:1527 / 1535
页数:9
相关论文
共 44 条
  • [1] Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens
    Prinz, Ana
    Neumayer, Thomas
    Buehl, Wolf
    Vock, Lorenz
    Menapace, Rupert
    Findl, Oliver
    Georgopoulos, Michael
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 251 - 257
  • [2] Accuracy of Modern Intraocular Lens Formulas in Highly Myopic Eyes Implanted With Plate-Haptic Intraocular Lenses
    Mo, Er
    Chen, Zexin
    Feng, Ke
    Zhu, Zehui
    Xu, Jialin
    Zhu, Chenyuan
    Chang, Pingjun
    Li, Jin
    Zhao, Yun-e
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 105 - 116
  • [3] Dislocation of a plate-haptic silicone intraocular lens into the anterior chamber
    Faucher, A
    Rootman, DS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01): : 169 - 171
  • [4] Clinical Performance of New Enhanced Monofocal Intraocular Lenses: Comparison of Hydrophobic C-loop and Hydrophilic Plate-Haptic Platform
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    ADVANCES IN THERAPY, 2023, 40 (10) : 4561 - 4573
  • [5] Clinical Performance of New Enhanced Monofocal Intraocular Lenses: Comparison of Hydrophobic C-loop and Hydrophilic Plate-Haptic Platform
    Andreas F. Borkenstein
    Eva-Maria Borkenstein
    Advances in Therapy, 2023, 40 : 4561 - 4573
  • [6] Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes
    Jiaqi Meng
    Wenwen He
    Xianfang Rong
    Ao Miao
    Yi Lu
    Xiangjia Zhu
    Eye and Vision, 7
  • [7] Repositioning a posteriorly dislocated silicone plate-haptic toric intraocular lens
    Van Brummen, Alexandra J.
    Crowell, Eric L.
    Ghergherehchi, Layla M.
    Wang, Nan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04): : 394 - 397
  • [8] Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes
    Meng, Jiaqi
    He, Wenwen
    Rong, Xianfang
    Miao, Ao
    Lu, Yi
    Zhu, Xiangjia
    EYE AND VISION, 2020, 7 (01)
  • [9] Posterior capsule tear with plate-haptic silicone intraocular lens dislocation
    Negi, A
    Sinha, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (10): : 1558 - 1559
  • [10] Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens
    Saldanha, Mario J.
    Benjamin, Larry
    Patel, Chetan K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10): : 1751 - 1755