Biological versus mechanical prostheses for aortic valve replacement

被引:13
|
作者
Rodriguez-Caulo, Emiliano A. [1 ,7 ]
Blanco-Herrera, Oscar R. [2 ]
Berastegui, Elisabet [3 ]
Arias-Dachary, Javier [4 ]
Souaf-Khalafi, Souhayla [5 ]
Parody-Cuerda, Gertrudis [1 ]
Laguna, Gregorio [6 ]
机构
[1] Virgen Macarena Univ Hosp, Cardiovasc Surg Dept, Seville, Spain
[2] La Fe Univ Hosp, Cardiovasc Surg Dept, Valencia, Spain
[3] Germans Trias I Pujol Hosp, Cardiovasc Surg Dept, Badalona, Spain
[4] Reina Sofia Univ Hosp, Cardiovasc Surg Dept, Cordoba, Spain
[5] Clin Univ Hosp, Cardiovasc Surg Dept, Santiago De Compostela, Spain
[6] Clin Univ Hosp, Cardiovasc Surg Dept, Valladolid, Spain
[7] Virgen Macarena Univ Hosp, Cardiovasc Surg Dept, Calle Dr Fedriani S-N, Seville 41009, Spain
来源
关键词
Key Words; aortic valve stenosis; survival analysis; long-term adverse effects; heart valve disease; LONG-TERM OUTCOMES; TASK-FORCE; BIOPROSTHESIS; EXPERIENCE; MITROFLOW;
D O I
10.1016/j.jtcvs.2021.01.118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Long-term real-world outcomes are critical for informing decisions about biological (Bio) or mechanical (Mech) prostheses for aortic valve replace-ment, particularly in patients aged between 50 and 65 years. The objective was to compare long-term survival and major adverse cardiac and cardiovascular events (ie, stroke, reoperation, and major bleeding) within this population.Methods: This was a multicenter observational study including all patients aged be-tween 50 and 65 years who underwent an aortic valve replacement because of se-vere isolated aortic stenosis between the years 2000 and 2018. A total of 5215 patients from 27 Spanish hospitals were registered with a follow-up of 15 years. Multivariable analyses, including a 2:1 propensity score matching (1822 Mech and 911 Bio) and competing risks analyses were applied.Results: Bio prostheses were implanted in 19% of patients (n = 992). No significant differences were observed between matched groups in long-term survival (hazard ratio [HR], 1.14; 95% confidence interval [CI], 0.88-1.47; P = .33). Stroke rates were higher for Mech prostheses, but not significant (HR, 0.72; 95% CI, 0.50-1.03; P = .07). Finally, higher rates of major bleeding were found in the Mech group (HR, 0.65; 95% CI, 0.49-0.87; P = .004), whereas reoperation was more frequent among the Bio group (HR, 3.04; 95% CI, 1.80-5.14; P < .001). Bio prostheses increased from 13% in the period from 2000 to 2008 to 24% in 2009 to 2018.Conclusions: Long-term survival was comparable among groups in patients be-tween 50 and 65 years of age. Mech prostheses were associated with a higher risk of major bleeding, whereas Bio prostheses entailed higher reoperation rates. Bio prostheses seem a reasonable choice for patients between 50 and 65 years in Spain. (J Thorac Cardiovasc Surg 2023;165:609-17)
引用
收藏
页码:609 / +
页数:16
相关论文
共 50 条
  • [31] Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
    Paolo Berretta
    Marco Di Eusanio
    Journal of Geriatric Cardiology, 2016, 13 (06) : 504 - 510
  • [32] Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses
    Berretta, Paolo
    Di Eusanio, Marco
    JOURNAL OF GERIATRIC CARDIOLOGY, 2016, 13 (06) : 504 - 510
  • [33] DOUBLE VALVE REPLACEMENT: BIOLOGICAL VERSUS MECHANICAL PROTHESES
    Elmistekawy, E.
    Chan, V.
    Lam, B.
    Mesana, T. G.
    Ruel, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S386 - S386
  • [34] A controversial Debate: biological versus mechanical Valve Replacement
    Kallenbach, Klaus
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2021, 35 (06): : 317 - 319
  • [35] Aortic valve replacement in patients aged 50 to 70 years: Improved outcome with mechanical versus biologic prostheses
    Brown, Morgan L.
    Schaff, Hartzell V.
    Lahr, Brian D.
    Mullany, Charles J.
    Sundt, Thoralf M.
    Dearani, Joseph A.
    McGregor, Christopher G.
    Orszulak, Thomas A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04): : 878 - 884
  • [36] Mechanical Versus Biologic Prostheses for Surgical Aortic Valve Replacement in Patients Aged 50 to 70 INVITED COMMENTARY
    Chiang, Yuting
    ANNALS OF THORACIC SURGERY, 2020, 110 (01): : 110 - 110
  • [37] SHORT- AND LONG-TERM PERFORMANCE OF MECHANICAL VERSUS BIOLOGICAL PROSTHESES FOR AORTIC VALVE REPLACEMENT IN PATIENTS WITH SEVERE SYMPTOMATIC AORTIC STENOSIS OVER 65 YEARS
    Perez, D.
    Maroto, L.
    Cobiella, J.
    Montero, L.
    Torres, B.
    Carnero, M.
    Sanchez, Marti B.
    Diaz, A.
    Cuervo, J.
    VALUE IN HEALTH, 2022, 25 (01) : S26 - S26
  • [38] Aortic valve replacement with mechanical and biologic prostheses in middle-aged patients
    Carrier, M
    Pellerin, M
    Perrault, LP
    Pagé, P
    Hébert, Y
    Cartier, R
    Dyrda, I
    Pelletier, LC
    ANNALS OF THORACIC SURGERY, 2001, 71 (05): : S253 - S256
  • [39] Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses
    Notzold, A
    Droste, DW
    Hagedorn, G
    Berndt, S
    Kaps, M
    Graf, B
    Sievers, HH
    CIRCULATION, 1997, 96 (06) : 1843 - 1846
  • [40] Quality of Life and Anxiety in Younger Patients after Biological versus Mechanical Aortic Valve Replacement
    Kottmaier, Marc
    Hettich, Ina
    Deutsch, Marcus-Andre
    Badiu, Catalin
    Krane, Markus
    Lange, Ruediger
    Bleiziffer, Sabine
    THORACIC AND CARDIOVASCULAR SURGEON, 2017, 65 (03): : 198 - 205