Circulating microemboli in patients after aortic valve replacement with pulmonary autografts and mechanical valve prostheses

被引:24
|
作者
Notzold, A
Droste, DW
Hagedorn, G
Berndt, S
Kaps, M
Graf, B
Sievers, HH
机构
[1] UNIV LUBECK,KLIN HERZCHIRURG,D-23538 LUBECK,GERMANY
[2] UNIV LUBECK,DEPT NEUROL,D-23538 LUBECK,GERMANY
[3] UNIV MUNSTER,DEPT NEUROL,D-4400 MUNSTER,GERMANY
[4] KLINIKUM SCHWERIN,DEPT CARDIOL,SCHWERIN,GERMANY
关键词
valves; surgery; embolism; microspheres; cerebrovascular circulation;
D O I
10.1161/01.CIR.96.6.1843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The pulmonary autograft procedure (Ross) is now considered the gold standard for aortic valve replacement. One of its advantages is the freedom from macroemboli without anticoagulation. Whether this holds true for circulating microemboli, detectable as high-intensity transient Doppler signals (HITS), has not yet been verified. Methods and Results We investigated 8 patients (2 women, 6 men; mean age, 50.6 +/- 17.9 years) after the Ross procedure, 9 patients (3 women, 6 men; mean age, 67.2 +/- 9.46 years) after aortic valve replacement with a mechanical valve prosthesis, and 12 young healthy volunteers by unilateral 1 hour recording of the middle cerebral artery on digital audio tape. Patients with extracranial carotid artery disease were excluded by color duplex sonography. During the off-line evaluation, the investigator was not aware of any patient details. No HITS were detected in healthy volunteers (95% confidence interval [CI], 0% to 26.46%). After the Ross procedure, 1 patient had 11 and 1 patient had 1 HITS (95% CI, 3.19% to 65.09%). All recipients of mechanical valves had HITS, ranging from 2 to 84 per hour (95% CI, 66.7% to 100%). Significantly more recipients of mechanical valves exhibited HITS than recipients of pulmonary autografts (P<.O5) or control subjects (P<.05). Conclusions In contrast to mechanical valves, pulmonary autografts are seldom the source of microemboli, confirming the pulmonary autograft as the superior substitute for aortic valve replacement.
引用
收藏
页码:1843 / 1846
页数:4
相关论文
共 50 条
  • [1] Quality of life in aortic valve replacement:: pulmonary autografts versus mechanical prostheses
    Nötzold, A
    Hüppe, M
    Schmidtke, C
    Blömer, P
    Uhlig, T
    Sievers, HH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (07) : 1963 - 1966
  • [2] Aortic allografts and pulmonary autografts for replacement of the aortic valve and aortic root
    Kouchoukos, NT
    ANNALS OF THORACIC SURGERY, 1999, 67 (06): : 1846 - 1848
  • [3] Exercise after aortic valve replacement: Comparison of pulmonary autografts versus aortic homografts
    Laforest, I
    Pibarot, P
    Briand, M
    Cartier, PC
    Dumesnil, JGG
    CIRCULATION, 2001, 104 (17) : 760 - 760
  • [4] Circulating microemboli after composite replacement or valve-sparing aortic root surgery
    Nötzold, A
    Gerriets, T
    Eggers, J
    Kupiske, G
    Seidel, G
    Kaps, M
    Sievers, HH
    THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (03): : 141 - 144
  • [5] Pulmonary valve replacement: A role for mechanical prostheses?
    Rosti, L
    Murzi, B
    Colli, AM
    Festa, P
    Redaelli, S
    Frigiola, A
    ANNALS OF THORACIC SURGERY, 1998, 65 (03): : 889 - 890
  • [6] Outcome after aortic valve replacement: Comparison of homografts with mechanical prostheses
    Kilian, Eckehard
    Oberhoffer, Martin
    Kaczmarek, Ingo
    Bauerfeind, Daniel
    Kreuzer, Eckart
    Reichart, Bruno
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (04): : 404 - 409
  • [7] Prosthetic Valve Endocarditis After Aortic Valve Replacement: Differences Between Biological and Mechanical Prostheses
    Timmermans, Naomi
    Lam, Ka Yan
    van Straten, Albert
    van't Veer, Marcel
    Soliman-Hamad, Mohamed
    HEART LUNG AND CIRCULATION, 2024, 33 (01): : 130 - 137
  • [8] Hemolysis after mitral valve replacement with mechanical valve prostheses
    Ninomiya M.
    Yagyu K.
    Kaneko Y.
    Kotsuka Y.
    Takamoto S.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2001, 49 (4): : 230 - 235
  • [9] Is there a role for mechanical valve prostheses in pulmonary valve replacement late after tetralogy of Fallot repair?
    Abbas, Jonathan Raihan
    Hoschtitzky, J. Andreas
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (05) : 661 - 666
  • [10] Biological versus mechanical prostheses for aortic valve replacement
    Rodriguez-Caulo, Emiliano A.
    Blanco-Herrera, Oscar R.
    Berastegui, Elisabet
    Arias-Dachary, Javier
    Souaf-Khalafi, Souhayla
    Parody-Cuerda, Gertrudis
    Laguna, Gregorio
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 165 (02): : 609 - +