Hemolysis after mitral valve replacement with mechanical valve prostheses

被引:0
|
作者
Ninomiya M. [1 ]
Yagyu K. [2 ]
Kaneko Y. [1 ]
Kotsuka Y. [1 ]
Takamoto S. [1 ]
机构
[1] Department of Cardiothoracic Surgery, Faculty of Medicine, University of Tokyo, Tokyo, 113-01, 6-15-13-9 Hon-Komagome, Bunkyo-ku
[2] Department of Cardiovascular Surgery, Japanese Red Cross Medical Center, Tokyo
关键词
mitral valve replacement; hemolysis; mechanical heart valve prosthesis;
D O I
10.1007/BF02913521
中图分类号
学科分类号
摘要
OBJECTIVE: We evaluated effects of type, size, and orientation of mechanical mitral valve prostheses on hemolysis. METHODS: Subjects were 84 patients who had undergone mitral valve replacement. Lactate dehydrogenase was mainly used as a marker of hemolysis and was measured before surgery, 1 month after surgery, and in the late postoperative period. RESULTS: Valves used included 16 Medtronic-Hall, 32 St. Jude Medical, and 36 CarboMedics valves. Medtronic-Hall valves caused less hemolysis than St. Jude Medical or CarboMedics valves in the late postoperative period. This resulted because hemolysis due to Medtronic-Hall valves was more severe 1 month after surgery than in the late postoperative period and because hemolysis due to St. Jude Medical or CarboMedics valves was more severe in the late postoperative period than 1 month after surgery. One reason for this finding is that cardiac output was greater in the late postoperative period than 1 month after surgery, making regurgitation through the pivots of bileaflet valves more severe. The orifice area and the orientation of prostheses did not affect hemolysis. CONCLUSION: St. Jude Medical or CarboMedics valves caused more severe hemolysis than Medtronic-Hall valves in the late postoperative period.
引用
收藏
页码:230 / 235
页数:5
相关论文
共 50 条
  • [1] Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prostheses
    Ismeno, G
    Renzulli, A
    Carozza, A
    De Feo, M
    Iannuzzi, M
    Sante, P
    Cotrufo, M
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (02) : 179 - 183
  • [2] Hemolysis in patients with mechanical mitral valve replacement
    TS Shivkumaraswamy
    V Srivastava
    K Ashok Shyam
    P Mishra
    B Radhakrishnan
    JV Khandekar
    NB Agrawal
    JMS Khandeparkar
    AM Patwardhan
    [J]. Indian Journal of Thoracic and Cardiovascular Surgery, 2006, 22 (1) : 59 - 59
  • [3] Results after mitral valve replacement with mechanical prostheses in young children
    Alsoufi, Bahaaldin
    Manlhiot, Cedric
    McCrindle, Brian W.
    Al-Halees, Zohair
    Sallehuddin, Ahmed
    Al-Oufi, Saud
    Saad, Elias
    Fadel, Bahaa
    Canver, Charles C.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05): : 1189 - U120
  • [4] A CASE OF MECHANICAL HEMOLYSIS MANAGED BY VALVE-IN-VALVE TRANSCATHETER MITRAL VALVE REPLACEMENT
    Desai, Anand
    Syed, Asim
    Lodhi, Hamza
    Mathews, Adithya Thomas
    Morcos, Ramez
    Khan, Harris
    Rodriguez-Paz, Enrique
    Topacio, Tracey
    Painter, Kapil Hemant
    Khalili, Houman
    Maini, Brijeshwar Singh
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 3281 - 3281
  • [5] Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement
    Goldstone, Andrew B.
    Chiu, Peter
    Baiocchi, Michael
    Lingala, Bharathi
    Patrick, William L.
    Fischbein, Michael P.
    Woo, Y. Joseph
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2017, 377 (19): : 1847 - 1857
  • [6] Risk of repeat mitral valve replacement for failed mitral valve prostheses
    Potter, DD
    Sundt, TM
    Zehr, KJ
    Dearani, JA
    Daly, RC
    Mullany, CJ
    McGregor, CGA
    Puga, FJ
    Schaff, HV
    Orszulak, TA
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (01): : 67 - 72
  • [7] HEMOLYSIS IN MITRAL VALVULAR DISEASE AND MITRAL BALL VALVE PROSTHESES
    MYHRE, E
    DALE, J
    [J]. ACTA MEDICA SCANDINAVICA, 1971, 189 (06): : 547 - +
  • [8] Hemolysis after transcatheter mitral valve replacement: An underreported phenomenon!
    Okuya, Yoshiyuki
    Moussa, Issam D.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (04) : 786 - 787
  • [9] HEMOLYSIS FOLLOWING MITRAL VALVE REPLACEMENT WITH BEALL VALVE PROSTHESIS
    WILLIAMS, JC
    VERNON, CR
    DAICOFF, GR
    BARTLEY, TD
    WHEAT, MW
    RAMSEY, HW
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1971, 61 (03): : 393 - &
  • [10] RESULTS OF RANDOMIZED MITRAL-VALVE REPLACEMENT WITH MECHANICAL PROSTHESES AFTER 15 YEARS
    SCHULTE, HD
    HORSTKOTTE, D
    BIRCKS, W
    STRAUER, BE
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (10): : 611 - 616