摘要
Congested reinforcement may lead to difficulties with compacting concrete and reduce the connection efficiency. To overcome this problem, using large-diameter longitudinal rebar to replace medium-diameter longitudinal rebar to reduce the number of longitudinal rebars may be a useful mean. However, the seismic behavior of precast concrete (PC) columns with different-diameter longitudinal rebars was still unclear. In order to evaluate the influence of large-diameter longitudinal rebar replacement on the seismic behavior of PC columns, a series of large-scale reinforced concrete (RC) columns adopting similar concrete strength, longitudinal rebar ratio, and transverse rebar ratio was fabricated and tested. Six of the columns were prefabricated with grouted sleeve connections and the remaining two were cast in place (CIP) for reference. The longitudinal rebar diameter varied from 18 mm to 32 mm. A low-cycle reversed horizontal load was applied to study their seismic performance, including failure modes, load-bearing capacity, hysteresis behavior, stiffness degeneration, and energy-dissipation capacity. The test results showed that the PC column with large-diameter longitudinal rebar replacement performed similarly to CIP columns in general. The column with large-diameter longitudinal rebar suffered significant bond-slip between longitudinal rebar and concrete, especially for columns with a high axial compressive ratio of 0.6. It may be of detriment to the seismic behavior of the columns to some extent. Additionally, with the increase in the diameter of longitudinal rebar, the ductility and energy-dissipation capacity of PC columns were reduced slightly. In the grouted sleeve region, a local rigid zone was formed, making its overall lateral stiffness higher than that of corresponding CIP columns. It is recommended to extend the strengthening zone, with closer transverse reinforcement, to two times the column depth of the PC columns with grouted sleeve connections, as the plastic hinges may be shifted upward.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Performance of precast concrete bridge piers with grouted sleeve connections against vehicle impact
    Zhao, Wuchao
    Feng, Huida
    Ye, Jihong
    Qian, Jiang
    STRUCTURES, 2022, 44 : 1874 - 1885
  • [42] Numerical study on seismic behavior of precast bridge columns with large-diameter bars and UHPC grout considering the bar-slip effect
    Wang, Zhen
    Wang, Jingquan
    Zhao, Guotang
    Zhang, Jian
    BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (10) : 4963 - 4984
  • [43] Experimental study on seismic response of precast bridge piers with double-grouted sleeve connections
    Liu, Yang
    Li, Xinping
    Zheng, Xiaohong
    Song, Zhuo
    ENGINEERING STRUCTURES, 2020, 221 (221)
  • [44] Numerical study on seismic behavior of precast bridge columns with large-diameter bars and UHPC grout considering the bar-slip effect
    Zhen Wang
    Jingquan Wang
    Guotang Zhao
    Jian Zhang
    Bulletin of Earthquake Engineering, 2020, 18 : 4963 - 4984
  • [45] Precast Concrete Bridge Column-Footing Connections with Recessed Grouted Splice Sleeve Connectors
    Barton, Ryan D.
    Ameli, M. J.
    Pantelides, Chris P.
    ACI STRUCTURAL JOURNAL, 2022, 119 (01) : 215 - 226
  • [46] Design of large diameter hybrid connections grouted with high performance concrete
    Schaumann, Peter
    Wilke, Fabian
    PROCEEDINGS OF THE SEVENTEENTH (2007) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1- 4, PROCEEDINGS, 2007, : 340 - 347
  • [47] Considerations for precast concrete girder end regions with large-diameter strands
    Harries, Kent A.
    Liu, Tianqiao
    Shahrooz, Bahram M.
    Miller, Richard A.
    Castrodale, Reid W.
    PCI Journal, 2024, 69 (05): : 27 - 44
  • [48] GROUTED AND DOWELED JOINTED PRECAST CONCRETE COLUMNS - BEHAVIOR IN COMBINED BENDING AND COMPRESSION
    KUTTAB, A
    DOUGILL, JW
    MAGAZINE OF CONCRETE RESEARCH, 1988, 40 (144) : 131 - 142
  • [49] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M. J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI JOURNAL, 2015, : 80 - 103
  • [50] Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction
    Ameli, M.J.
    Parks, Joel E.
    Brown, Dylan N.
    Pantelides, Chris P.
    PCI Journal, 2015, 60 (02): : 80 - 103