Effects of Large-Diameter Rebar Replacement on Seismic Behavior of Precast Concrete Columns with Grouted Sleeve Connections

被引:4
|
作者
Wang, Qiang [1 ,2 ,3 ]
Qin, Weiyang [1 ]
Lu, Chunling [1 ]
机构
[1] Guilin Univ Technol, GuangXi Key Lab New Energy & Bldg Energy Saving, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Civil Engn & Architecture, Guilin 541004, Peoples R China
[3] Guilin Univ Technol, Collaborat Innovat Ctr Explorat Hidden Nonferrous, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
diameter of rebar; precast concrete column; seismic behavior; test; grouted sleeve; PERFORMANCE; DESIGN;
D O I
10.3390/buildings13030706
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Congested reinforcement may lead to difficulties with compacting concrete and reduce the connection efficiency. To overcome this problem, using large-diameter longitudinal rebar to replace medium-diameter longitudinal rebar to reduce the number of longitudinal rebars may be a useful mean. However, the seismic behavior of precast concrete (PC) columns with different-diameter longitudinal rebars was still unclear. In order to evaluate the influence of large-diameter longitudinal rebar replacement on the seismic behavior of PC columns, a series of large-scale reinforced concrete (RC) columns adopting similar concrete strength, longitudinal rebar ratio, and transverse rebar ratio was fabricated and tested. Six of the columns were prefabricated with grouted sleeve connections and the remaining two were cast in place (CIP) for reference. The longitudinal rebar diameter varied from 18 mm to 32 mm. A low-cycle reversed horizontal load was applied to study their seismic performance, including failure modes, load-bearing capacity, hysteresis behavior, stiffness degeneration, and energy-dissipation capacity. The test results showed that the PC column with large-diameter longitudinal rebar replacement performed similarly to CIP columns in general. The column with large-diameter longitudinal rebar suffered significant bond-slip between longitudinal rebar and concrete, especially for columns with a high axial compressive ratio of 0.6. It may be of detriment to the seismic behavior of the columns to some extent. Additionally, with the increase in the diameter of longitudinal rebar, the ductility and energy-dissipation capacity of PC columns were reduced slightly. In the grouted sleeve region, a local rigid zone was formed, making its overall lateral stiffness higher than that of corresponding CIP columns. It is recommended to extend the strengthening zone, with closer transverse reinforcement, to two times the column depth of the PC columns with grouted sleeve connections, as the plastic hinges may be shifted upward.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic performance of prefabricated concrete columns with grouted sleeve connections, and a deformation-capacity estimation method
    Ding, Mengjia
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Du, Xiuli
    Fang, Rong
    JOURNAL OF BUILDING ENGINEERING, 2022, 55
  • [32] Structural Behavior of Precast Reinforced Concrete Shear Walls with Large-Diameter Bars
    Chen, Xin
    Liu, Ming
    Biondini, Fabio
    Rosati, Gianpaolo
    ACI STRUCTURAL JOURNAL, 2019, 116 (05) : 77 - 86
  • [33] Experimental study on seismic behavior of precast concrete columns with treatment of sleeve grouting defects
    Li, Xiangmin
    Xiao, Shun
    Xu, Qingfeng
    Wang, Zhuolin
    Gao, Rundong
    Zhang, Fuwen
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (05): : 15 - 26
  • [34] Experimental study on effect of sleeve grouting defects on seismic behavior of precast concrete columns
    Xiao S.
    Li X.
    Xu Q.
    Jiang H.
    Gao R.
    Wang Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (05): : 112 - 121
  • [35] Experimental investigation on the behavior of grouted restrained anchor connections for cluster-reinforced precast concrete columns
    Li, Jiaxu
    Liu, Ming
    Pei, Ziyang
    Chen, Xin
    Biondini, Fabio
    STRUCTURES, 2023, 49 : 1168 - 1181
  • [36] Experimental Study on Seismic Behavior of Precast Frame Columns with Vertical Reinforcement Spliced with Grouted Sleeve Lapping Connectors
    Yu, Qiong
    Zhang, Liang
    Bai, Shaohua
    Fan, Baoxiu
    Chen, Zhenhai
    Li, Ling-Zhi
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [37] Experimental study on seismic behaviour of precast recycled fine aggregate concrete columns with pressed sleeve connections
    Yuan, Chang-Min
    Cai, Jian
    Chen, Qing-Jun
    Liu, Xinpei
    Zuo, Zhiliang
    He, An
    Huang, Houjun
    STRUCTURES, 2023, 48 : 1373 - 1390
  • [38] Seismic performance of precast concrete shear wall using grouted sleeve connections for section steels reinforced at wall ends
    Lu, Yilin
    Jiang, Luyang
    Lin, Feng
    STRUCTURES, 2023, 57
  • [39] Seismic Performance of Five-Spiral Concrete Columns with Large-Diameter Longitudinal Reinforcement
    Ou, Yu-Chen
    Li, Brandon
    ACI STRUCTURAL JOURNAL, 2023, 120 (05) : 37 - 47
  • [40] Experimental study on the tensile performance of a large-diameter UHPC grouted sleeve with thread
    Huang, Zhen
    Yang, Yang
    Zhang, Jiabing
    Ma, Shaokun
    Cao, Chen
    ENGINEERING STRUCTURES, 2023, 294