Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

被引:1
|
作者
Topriceanu, Constantin-Cristian [1 ,2 ,5 ]
Fornasiero, Massimiliano [3 ]
Seo, Han [4 ]
Webber, Matthew [1 ,2 ,4 ,5 ]
Keenan, Kathryn E. E. [6 ]
Stupic, Karl F. F. [6 ]
Bruehl, Ruediger [7 ]
Ittermann, Bernd [7 ]
Price, Kirsty [8 ]
McGrath, Louise [8 ]
Pang, Wenjie [9 ]
Hughes, Alun D. D. [2 ,5 ]
Nezafat, Reza [10 ]
Kellman, Peter [11 ]
Pierce, Iain [1 ,2 ]
Moon, James C. C. [1 ,2 ]
Captur, Gabriella [2 ,4 ,5 ,12 ]
机构
[1] Barts Hlth NHS Trust, Barts Heart Ctr, ECIA 7BE, London, England
[2] UCL, Inst Cardiovasc Sci, Huntley St, London WC1E 6DD, England
[3] UCL Med Sch, 74 Huntley St, London WC1E 6DE, England
[4] Royal Free London NHS Fdn Trust, Ctr Inherited Heart Muscle Condit, Dept Cardiol, Pond St, London NW3 2QG, England
[5] UCL, Med Res Council Unit Lifelong Hlth & Ageing, 1-19 Torrington Pl, London WC1E 7HB, England
[6] NIST, 325 Broadway, Boulder, CO 80305 USA
[7] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[8] UCL Bloomsbury Ctr Clin Phenotyping, London WC1E 6HX, England
[9] Resonance Hlth RH, 141 Burswood Rd, Burswood, WA 6100, Australia
[10] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Med, Cardiovasc Div, 330 Brookline Ave, Boston, MA 02215 USA
[11] NHLBI, NIH, Bethesda, MD 20892 USA
[12] UCL, Inst Cardiovasc Sci, Inherited Heart Muscle Condit, Gower St, London WC1E 6BT, England
基金
英国医学研究理事会; 欧盟地平线“2020”; 英国经济与社会研究理事会;
关键词
T-1; mapping; T-2; Phantom; Quality control; MRI; FIELD; ECHO; SEQUENCES; VALUES; 3T;
D O I
10.1186/s12968-023-00926-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionA long T-2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T-2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T-2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T-2 mapping in CMR.AimTo fabricate and assess a phantom dedicated to the quality assurance of T-2 mapping in CMR.MethodA T-2 mapping phantom was manufactured to contain 9 T-1 and T-2 (T-1|T-2) tubes to mimic clinically relevant native and post-contrast T-2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B-0 and B-1 uniformity using field maps, and temperature dependence. Baseline reference T-1|T-2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T-1|T-2 was determined by repeated T-1|T-2 mapping of the phantom at baseline and at 12 months.ResultsThe phantom embodies 9 internal agarose-containing T-1|T-2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T-2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to <= 7.2 ms [< 14.7%] for estimated T-2 by balanced steady-state free precession T-2 mapping compared to reference SE T-2 with the exception of the post-contrast tube of ultra-low T-1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B-0 and B-1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 degrees C range confirmed the greater stability of shorter vs longer T-1|T-2 tubes. Excellent long-term (12-month) reproducibility of measured T-1|T-2 was demonstrated across both field strengths (all coefficients of variation < 1.38%).ConclusionThe T-2 mapping phantom demonstrates excellent structural integrity, B-0 and B-1 uniformity, and reproducibility of its internal tube T-1|T-2 out to 1 year. This device may now be mass-produced to support the quality assurance of T-2 mapping in CMR.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Value of black blood T2*cardiovascular magnetic resonance
    Smith, Gillian C.
    Carpenter, John Paul
    He, Taigang
    Alam, Mohammed H.
    Firmin, David N.
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [32] Cardiovascular magnetic resonance tagging imaging correlates with myocardial dysfunction and T2 mapping in idiopathic dilated cardiomyopathy
    Kono, Atsushi K.
    Croisille, Pierre
    Nishii, Tatsuya
    Nishiyama, Koya
    Kyotani, Katsusuke
    Shigeru, Mayumi
    Takamine, Sachiko
    Fujiwara, Sei
    Sugimura, Kazuro
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 145 - 152
  • [33] Cardiovascular magnetic resonance tagging imaging correlates with myocardial dysfunction and T2 mapping in idiopathic dilated cardiomyopathy
    Atsushi K. Kono
    Pierre Croisille
    Tatsuya Nishii
    Koya Nishiyama
    Katsusuke Kyotani
    Mayumi Shigeru
    Sachiko Takamine
    Sei Fujiwara
    Kazuro Sugimura
    The International Journal of Cardiovascular Imaging, 2014, 30 : 145 - 152
  • [34] Value of black blood T2* cardiovascular magnetic resonance
    Gillian C Smith
    John Paul Carpenter
    Taigang He
    Mohammed H Alam
    David N Firmin
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 13
  • [35] Cardiovascular magnetic resonance in β-thalassemia major: beyond T2*
    Antonella Meloni
    Luca Saba
    Filippo Cademartiri
    Vincenzo Positano
    Laura Pistoia
    Riccardo Cau
    La radiologia medica, 2024, 129 (12) : 1812 - 1822
  • [36] Clinical utility of cardiac magnetic resonance T2 mapping for acute myocardial edema
    Usman A.A.
    Wasielewski M.
    Collins J.D.
    Galizia M.S.
    Popescu A.R.
    Carr J.C.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [37] T2 and T2*Placental Magnetic Resonance Imaging in Pre-Eclampsia.
    Ho, Alison
    Jana, Hutter
    Jackson, Laurence
    Story, Lisa
    McCabe, Laura
    Hajnal, Joseph V.
    Rutherford, Mary
    Chappell, Lucy
    REPRODUCTIVE SCIENCES, 2019, 26 : 357A - 358A
  • [38] T2 mapping and T2*imaging in heart failure
    Lota, A. S.
    Gatehouse, P. D.
    Mohiaddin, R. H.
    HEART FAILURE REVIEWS, 2017, 22 (04) : 431 - 440
  • [39] Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2*and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI)
    Messroghli, Daniel R.
    Moon, James C.
    Ferreira, Vanessa M.
    Grosse-Wortmann, Lars
    He, Taigang
    Kellman, Peter
    Mascherbauer, Julia
    Nezafat, Reza
    Salerno, Michael
    Schelbert, Erik B.
    Taylor, Andrew J.
    Thompson, Richard
    Ugander, Martin
    van Heeswijk, Ruud B.
    Friedrich, Matthias G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [40] Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI)
    Daniel R. Messroghli
    James C. Moon
    Vanessa M. Ferreira
    Lars Grosse-Wortmann
    Taigang He
    Peter Kellman
    Julia Mascherbauer
    Reza Nezafat
    Michael Salerno
    Erik B. Schelbert
    Andrew J. Taylor
    Richard Thompson
    Martin Ugander
    Ruud B. van Heeswijk
    Matthias G. Friedrich
    Journal of Cardiovascular Magnetic Resonance, 19