Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

被引:1
|
作者
Topriceanu, Constantin-Cristian [1 ,2 ,5 ]
Fornasiero, Massimiliano [3 ]
Seo, Han [4 ]
Webber, Matthew [1 ,2 ,4 ,5 ]
Keenan, Kathryn E. E. [6 ]
Stupic, Karl F. F. [6 ]
Bruehl, Ruediger [7 ]
Ittermann, Bernd [7 ]
Price, Kirsty [8 ]
McGrath, Louise [8 ]
Pang, Wenjie [9 ]
Hughes, Alun D. D. [2 ,5 ]
Nezafat, Reza [10 ]
Kellman, Peter [11 ]
Pierce, Iain [1 ,2 ]
Moon, James C. C. [1 ,2 ]
Captur, Gabriella [2 ,4 ,5 ,12 ]
机构
[1] Barts Hlth NHS Trust, Barts Heart Ctr, ECIA 7BE, London, England
[2] UCL, Inst Cardiovasc Sci, Huntley St, London WC1E 6DD, England
[3] UCL Med Sch, 74 Huntley St, London WC1E 6DE, England
[4] Royal Free London NHS Fdn Trust, Ctr Inherited Heart Muscle Condit, Dept Cardiol, Pond St, London NW3 2QG, England
[5] UCL, Med Res Council Unit Lifelong Hlth & Ageing, 1-19 Torrington Pl, London WC1E 7HB, England
[6] NIST, 325 Broadway, Boulder, CO 80305 USA
[7] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[8] UCL Bloomsbury Ctr Clin Phenotyping, London WC1E 6HX, England
[9] Resonance Hlth RH, 141 Burswood Rd, Burswood, WA 6100, Australia
[10] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Med, Cardiovasc Div, 330 Brookline Ave, Boston, MA 02215 USA
[11] NHLBI, NIH, Bethesda, MD 20892 USA
[12] UCL, Inst Cardiovasc Sci, Inherited Heart Muscle Condit, Gower St, London WC1E 6BT, England
基金
英国医学研究理事会; 欧盟地平线“2020”; 英国经济与社会研究理事会;
关键词
T-1; mapping; T-2; Phantom; Quality control; MRI; FIELD; ECHO; SEQUENCES; VALUES; 3T;
D O I
10.1186/s12968-023-00926-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionA long T-2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T-2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T-2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T-2 mapping in CMR.AimTo fabricate and assess a phantom dedicated to the quality assurance of T-2 mapping in CMR.MethodA T-2 mapping phantom was manufactured to contain 9 T-1 and T-2 (T-1|T-2) tubes to mimic clinically relevant native and post-contrast T-2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B-0 and B-1 uniformity using field maps, and temperature dependence. Baseline reference T-1|T-2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T-1|T-2 was determined by repeated T-1|T-2 mapping of the phantom at baseline and at 12 months.ResultsThe phantom embodies 9 internal agarose-containing T-1|T-2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T-2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to <= 7.2 ms [< 14.7%] for estimated T-2 by balanced steady-state free precession T-2 mapping compared to reference SE T-2 with the exception of the post-contrast tube of ultra-low T-1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B-0 and B-1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 degrees C range confirmed the greater stability of shorter vs longer T-1|T-2 tubes. Excellent long-term (12-month) reproducibility of measured T-1|T-2 was demonstrated across both field strengths (all coefficients of variation < 1.38%).ConclusionThe T-2 mapping phantom demonstrates excellent structural integrity, B-0 and B-1 uniformity, and reproducibility of its internal tube T-1|T-2 out to 1 year. This device may now be mass-produced to support the quality assurance of T-2 mapping in CMR.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
    Anderson, LJ
    Holden, S
    Davis, B
    Prescott, E
    Charrier, CC
    Bunce, NH
    Firmin, DN
    Wonke, B
    Porter, J
    Walker, JM
    Pennell, DJ
    EUROPEAN HEART JOURNAL, 2001, 22 (23) : 2171 - 2179
  • [22] T2 mapping vs T2 weighted imaging in the detection of myocardial oedema
    Elisa McAlindon
    Peter Weale
    Jessica Harris
    David Smith
    Andreas Baumbach
    Tom Johnson
    Chiara Bucciarelli-Ducci
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [23] Myocardial T2 mapping by cardiovascular magnetic resonance reveals subclinical myocardial inflammation in patients with systemic lupus erythematosus
    Yan Zhang
    Celia P. Corona-Villalobos
    Adnan N. Kiani
    John Eng
    Ihab R. Kamel
    Stefan L. Zimmerman
    Michelle Petri
    The International Journal of Cardiovascular Imaging, 2015, 31 : 389 - 397
  • [24] MYOCARDIAL T1 AND T2 MAPPING BY CARDIOVASCULAR MAGNETIC RESONANCE IN IMMUNE CHECKPOINT INHIBITOR-ASSOCIATED MYOCARDITIS
    Thavendiranathan, Paaladinesh
    Zhang, Lili
    Zafar, Amna
    Mahmood, Syed S.
    Cabral, Marcella
    Nohria, Anju
    Thuny, Franck
    Gupta, Dipti
    Hartmann, Sarah E.
    Weinsaft, Jonathan
    Gilman, Hannah K.
    Kovacina, Bojan
    Michel, Caroline
    Mahmoudi, Michael
    Castro, Manuel Garcia De Yebenes
    Kwong, Raymond
    Coelho-Filho, Otavio R.
    Afilalo, Jonathan
    Nicolas, Eduardo Z.
    Baksi, Arun
    Wintersperger, Bernd
    Yang, Eric H.
    Lyon, Alexander R.
    Fradley, Michael G.
    Neilan, Tomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 3055 - 3055
  • [25] T2 mapping magnetic resonance imaging of cartilage in hemophilia
    Brakel, Benjamin A.
    Sussman, Marshall S.
    Majeed, Haris
    Teitel, Jerry
    Man, Carina
    Rayner, Tammy
    Weiss, Ruth
    Moineddin, Rahim
    Blanchette, Victor
    Doria, Andrea S.
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2023, 7 (06)
  • [26] Application of magnetic resonance T2 mapping in the temporomandibular joints
    Cao, Yang
    Xia, Chunchao
    Wang, Si
    He, Shushu
    Wamalwa, Peter
    Chen, Song
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (05): : 644 - 649
  • [27] Worldwide survey of T2* cardiovascular magnetic resonance in Thalassaemia
    Carpenter J.-P.
    He T.
    Kirk P.
    Anderson L.
    Porter J.B.
    Walker M.
    Galanello R.
    Danjou F.
    Forni G.
    Kattamis A.
    Ladis V.
    Drossou M.
    Vini D.
    Michos A.
    Perifanis V.
    Hazirolan T.
    Almeida A.
    Aydinok Y.
    Rangelova M.
    El-Beshlawy A.
    Elalfy M.
    Alnasser I.
    Daar S.
    Fernandes J.D.L.
    Pennell D.J.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [28] Improved Detection of Cardiac Sarcoidosis Using Magnetic Resonance with Myocardial T2 Mapping
    Crouser, Elliott D.
    Ono, Chikako
    Tam Tran
    He, Xin
    Raman, Subha V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189 (01) : 109 - 112
  • [29] INTERNATIONAL SURVEY OF T2*CARDIOVASCULAR MAGNETIC RESONANCE IN THALASSEMIA
    Carpenter, J. P.
    Roughton, M.
    Pennell, D.
    HAEMATOLOGICA, 2012, 97 : 248 - 249
  • [30] Myocardial T2* Mapping with Ultrahigh Field Magnetic Resonance: Physics and Frontier Applications
    Huelnhagen, Till
    Paul, Katharina
    Ku, Min-Chi
    Duarte, Teresa Serradas
    Niendorf, Thoralf
    FRONTIERS IN PHYSICS, 2017, 5