Determination of alectinib and its active metabolite in plasma by pipette-tip solid-phase extraction using porous polydopamine graphene oxide adsorbent coupled with high-performance liquid chromatography-ultraviolet detection

被引:4
|
作者
Zhang, Pengfei [1 ]
Wang, Wenyan [1 ]
Yin, Junfa [2 ]
Wang, Mingyu [3 ]
Han, Yehong [1 ]
Yan, Hongyuan [1 ]
机构
[1] Hebei Univ, Coll Pharmaceut Sci, Coll Chem & Mat Sci, Hebei Key Lab Publ Hlth Safety,Key Lab Med Chem &, Baoding 071002, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[3] Hebei Univ, Affiliated Hosp, Dept Pharm, Baoding 071002, Peoples R China
基金
中国国家自然科学基金;
关键词
Alectinib; Active metabolite; Plasma; Pipette-tip solid-phase extraction; High-performance liquid chromatography; KINASE INHIBITORS; MASS-SPECTROMETRY; M4;
D O I
10.1016/j.chroma.2023.464578
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alectinib is known as an effective targeted drug, which has excellent therapeutic effect on non-small cell lung cancer and can significantly prolong the survival of patients. Therapeutic drug monitoring is necessary due to the photo-instability of alectinib and the individual differences in patients. In this work, a porous polydopamine graphene oxide composite (PDAG) was prepared by a simple surface modification method. A PDAG-based pipette-tip solid-phase extraction (PT-SPE) coupled with HPLC-UV detection was proposed for the separation and detection of alectinib and its active metabolite M4 in plasma. The method was methodologically validated and showed good linearity in the range of 50-5000 ng mL(-1) (R-2 > 0.9995). The limit of detection (LOD) was 4.8 ng mL(-1) and 3.9 ng mL(-1) for alectinib and M4, respectively, and the limit of quantitation (LOQ) was 16.1 ng mL(-1) and 13.1 ng mL(-1), respectively. The intra-day and inter-day precision expressed by coefficient of variation was less than 4.8 %. The recovery of this method ranged from 84.9 % to 103.5 % with a standard deviation of less than 4.3 %. In conclusion, the established method is accurate, stable and inexpensive, and can be used to monitor the levels of alectinib and M4 in plasma, which provide technical and data support for exploring optimal individualized remedial dosing regimens.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Improved method for analyzing the degradation of estrogens in water by solid-phase extraction coupled with ultra performance liquid chromatography-ultraviolet detection
    Zheng, Minggang
    Wang, Ling
    Bi, Yuandui
    Liu, Feng
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2011, 23 (04) : 693 - 698
  • [43] Improved method for analyzing the degradation of estrogens in water by solid-phase extraction coupled with ultra performance liquid chromatography-ultraviolet detection
    Minggang Zheng Ling Wang Yuandui Bi Feng Liu College of Chemistry and Chemical Engineering and Environment Qingdao University Qingdao China The First Institute of Oceanography Qingdao China
    Journal of Environmental Sciences, 2011, 23 (04) : 693 - 698
  • [44] Determination of Faropenem in Human Plasma by Online Solid-Phase Extraction Coupled to High-Performance Liquid Chromatography with UV Detection and its Applications to a Pharmacokinetics Study
    Xie Rui
    Wen Jun
    Wei Hua
    Fan Guorong
    Wu Yutian
    Hu Zhuohan
    DRUG METABOLISM REVIEWS, 2009, 41 : 28 - 28
  • [45] DETERMINATION OF MOXIDECTIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED SOLID-PHASE EXTRACTION AND FLUORESCENCE DETECTION
    ALVINERIE, M
    SUTRA, JF
    BADRI, M
    GALTIER, P
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 674 (01): : 119 - 124
  • [46] DETERMINATION OF LOMEFLOXACIN IN HUMAN PLASMA BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION
    CARLUCCI, G
    CILLI, A
    LIBERATO, M
    MAZZEO, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) : 1105 - 1108
  • [47] DETERMINATION OF PENTOXIFYLLINE AND ITS METABOLITES IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH SOLID-PHASE EXTRACTION
    MANCINELLI, A
    PACE, S
    MARZO, A
    MARTELLI, EA
    PASSETTI, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01): : 101 - 107
  • [48] Determination of 5-fluorouracil in environmental samples by solid-phase extraction and high-performance liquid chromatography with ultraviolet detection
    Micoli, G
    Turci, R
    Arpellini, M
    Minoia, C
    JOURNAL OF CHROMATOGRAPHY B, 2001, 750 (01): : 25 - 32
  • [49] Determination of sulfadiazine in eggs using molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography
    He, Xiuping
    Tan, Liju
    Wu, Wei
    Wang, Jiangtao
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (11) : 2204 - 2212
  • [50] Determination of acyclovir and its metabolite 9-carboxymethoxymethylguanine in serum and urine using solid-phase extraction and high-performance liquid chromatography
    Svensson, JO
    Barkholt, L
    Sawe, J
    JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2): : 363 - 366