Determination of alectinib and its active metabolite in plasma by pipette-tip solid-phase extraction using porous polydopamine graphene oxide adsorbent coupled with high-performance liquid chromatography-ultraviolet detection

被引:4
|
作者
Zhang, Pengfei [1 ]
Wang, Wenyan [1 ]
Yin, Junfa [2 ]
Wang, Mingyu [3 ]
Han, Yehong [1 ]
Yan, Hongyuan [1 ]
机构
[1] Hebei Univ, Coll Pharmaceut Sci, Coll Chem & Mat Sci, Hebei Key Lab Publ Hlth Safety,Key Lab Med Chem &, Baoding 071002, Peoples R China
[2] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[3] Hebei Univ, Affiliated Hosp, Dept Pharm, Baoding 071002, Peoples R China
基金
中国国家自然科学基金;
关键词
Alectinib; Active metabolite; Plasma; Pipette-tip solid-phase extraction; High-performance liquid chromatography; KINASE INHIBITORS; MASS-SPECTROMETRY; M4;
D O I
10.1016/j.chroma.2023.464578
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alectinib is known as an effective targeted drug, which has excellent therapeutic effect on non-small cell lung cancer and can significantly prolong the survival of patients. Therapeutic drug monitoring is necessary due to the photo-instability of alectinib and the individual differences in patients. In this work, a porous polydopamine graphene oxide composite (PDAG) was prepared by a simple surface modification method. A PDAG-based pipette-tip solid-phase extraction (PT-SPE) coupled with HPLC-UV detection was proposed for the separation and detection of alectinib and its active metabolite M4 in plasma. The method was methodologically validated and showed good linearity in the range of 50-5000 ng mL(-1) (R-2 > 0.9995). The limit of detection (LOD) was 4.8 ng mL(-1) and 3.9 ng mL(-1) for alectinib and M4, respectively, and the limit of quantitation (LOQ) was 16.1 ng mL(-1) and 13.1 ng mL(-1), respectively. The intra-day and inter-day precision expressed by coefficient of variation was less than 4.8 %. The recovery of this method ranged from 84.9 % to 103.5 % with a standard deviation of less than 4.3 %. In conclusion, the established method is accurate, stable and inexpensive, and can be used to monitor the levels of alectinib and M4 in plasma, which provide technical and data support for exploring optimal individualized remedial dosing regimens.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Determination of celecoxib in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chow, HHS
    Anavy, N
    Salazar, D
    Frank, DH
    Alberts, DS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 167 - 174
  • [22] Determination of noscapine in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chollet, DF
    Ruols, C
    Arnera, V
    JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01): : 81 - 85
  • [23] Determination of atazanavir in human plasma using solid-phase extraction and high-performance liquid chromatography
    Cateau, E
    Tournier, N
    Dupuis, A
    Le Moal, G
    Venisse, N
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 791 - 795
  • [24] Solid-phase extraction and high-performance liquid chromatography applied to the determination of quinapril and its metabolite quinaprilat in urine
    Prieto, JA
    Alonso, RM
    Jiménez, RM
    Blanco, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (04) : 153 - 159
  • [25] Simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma using high-performance liquid chromatography with ultraviolet detection
    Abbara, C
    Aymard, G
    Hinh, S
    Diquet, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02): : 199 - 207
  • [26] Determination of melatonin in human plasma with solid-phase extraction, high-performance liquid chromatography and fluorescence detection
    Römsing, S
    Ulfberg, J
    Bergqvist, Y
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2003, 63 (01): : 81 - 88
  • [27] SIMPLE METHOD FOR THE DETERMINATION OF PAEONOL IN HUMAN AND RABBIT PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION AND ULTRAVIOLET DETECTION
    RILEY, CM
    REN, TC
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (02): : 432 - 437
  • [28] Simultaneous solid-phase extraction combined with liquid chromatography with ultraviolet absorbance detection for the determination of remifentanil and its metabolite in dog plasma
    Kabbaj, A
    Varin, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01): : 103 - 111
  • [29] Determination of the antihypertensive drug cilazapril and its active metabolite cilazaprilat in pharmaceuticals and urine by solid-phase extraction and high-performance liquid chromatography with photometric detection
    Prieto, JA
    Jiménez, RM
    Alonso, RM
    Ortiz, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 754 (01): : 23 - 34
  • [30] .Determination of itraconazole in human plasma by high-performance liquid chromatography with solid-phase extraction
    Ohkubo, T
    Osanai, T
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 94 - 98