Effect from usage and autoclave sterilization on torsional fracture resistance of heat-treated nickel-titanium instruments: an in-vitro study

被引:1
|
作者
Kang, Yoo Jung [1 ]
Alshehhi, Aisha [2 ]
Al Raeesi, Dana [3 ]
Alkhatib, Zuhair [2 ,4 ]
Jamal, Mohamed [2 ]
El Abed, Rashid [2 ]
Kim, Hyeon-Cheol [1 ]
机构
[1] Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Conservat Dent, Yangsan, South Korea
[2] Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai, U Arab Emirates
[3] Emirates Hlth Serv Estab, Endodont Dept, Dubai, U Arab Emirates
[4] Emirates Endodont Soc, Dubai, U Arab Emirates
关键词
fracture resistance; heat treatment; nickel-titanium files; torsional fracture; usage; sterilization; MECHANICAL-PROPERTIES; CYCLIC FATIGUE; STAINLESS-STEEL; CURRENT CHALLENGES; SHAPE-MEMORY; ROTARY; FILES; BEHAVIOR;
D O I
10.3389/fmats.2023.1215780
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aimed to evaluate the effect from usage and autoclaving on torsional fracture resistance of heat-treated nickel-titanium rotary instruments. ProTaper Gold F2 (PG) and TruNatomy Prime (TN) were selected. For group-N, new files were tested to make a baseline torsional resistance. For group-U, files underwent instrumentation in a J-shaped canal block, and files were tested. For group-S, files underwent instrumentation as in the group-U and followed by autoclave sterilization then were tested. Maximum torsional strength and distortion angel until fracture were measured using a customized device and toughness was calculated. Statistical analysis was conducted at the significance level of 95%. The topographic appearances of torsional fracture fragments were examined under scanning electron microscopy. PG showed significantly higher torsional strength after usage and sterilization; however, TN had reduced torsional strength (p < 0.05). PG showed significantly higher torsional strength in group-S than subgroup-N, while TN showed significantly lower torsional strength in group-U than group-N (p < 0.05). Regardless of the test conditions, PG showed significantly higher torsional strength and toughness than TN while TN had bigger distortion angle than PG (p < 0.05). The mechanical loads from usage and heat application during sterilization may result in alteration of torsional resistances according to geometry and alloy characteristics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel-Titanium Rotary Files
    El Abed, Rashid
    Al Raeesi, Dana
    Alshehhi, Aisha
    Alkhatib, Zuhair
    Khamis, Amar H.
    Jamal, Mohamed
    Kim, Hyeon-Cheol
    MATERIALS, 2023, 16 (06)
  • [2] Fracture Resistance of HeatTreated Nickel-Titanium Rotary Files After Usage and Autoclave Sterilization: An In Vitro Study
    El Abed, Rashid
    Alshehhi, Aisha
    Kang, Yoo Jung
    Al Raeesi, Dana
    Khamis, Amar H.
    Jamal, Mohamed
    Kim, Hyeon-Cheol
    JOURNAL OF ENDODONTICS, 2022, 48 (11) : 1428 - 1433
  • [3] Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments
    Zhao, D.
    Shen, Y.
    Peng, B.
    Haapasalo, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 990 - 995
  • [4] Torsional Resistance of Heat-Treated Nickel-Titanium Instruments under Different Temperature Conditions
    Jo, Hyo Jin
    Kwak, Sang Won
    Kim, Hyeon-Cheol
    Kim, Sung Kyo
    Ha, Jung-Hong
    MATERIALS, 2021, 14 (18)
  • [5] Evaluation of cyclic and torsional fatigue resistance of several heat-treated reciprocating nickel-titanium instruments
    Weissheimer, Theodoro
    Duarte, Marco Antonio Hungaro
    So, Marcus Vinicius Reis
    da Rosa, Ricardo Abreu
    Espinosa, Michel Klymus
    Vivan, Rodrigo Ricci
    Alcalde, Murilo Priori
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 (03) : 524 - 529
  • [6] Effect of sterilization on torsional fracture resistance of nickel-titanium rotary files
    Kiss, EP
    Murchison, DF
    Davis, BD
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 547 - 547
  • [7] Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and/or Sterilization
    Pedulla, Eugenio
    Benites, Angela
    La Rosa, Giusy M.
    Plotino, Gianluca
    Grande, Nicola M.
    Rapisarda, Ernesto
    Generali, Luigi
    JOURNAL OF ENDODONTICS, 2018, 44 (04) : 648 - 653
  • [8] Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study
    Lin, Jack Han-Hsing
    Karabucak, Bekir
    Lee, Su-Min
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (02) : 738 - 743
  • [9] Effect of Different Heat-treated Nickel-Titanium Files on Vertical Root Fracture Resistance
    Furuncuoglu, Fatma
    Kalyoncuoglu, Elif
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 (02): : 157 - 163
  • [10] Cyclic fatigue and torsional resistance of heat-treated One Curve compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    ENDO-ENDODONTIC PRACTICE TODAY, 2019, 13 (03): : 247 - 253