Fracture Resistance of HeatTreated Nickel-Titanium Rotary Files After Usage and Autoclave Sterilization: An In Vitro Study

被引:3
|
作者
El Abed, Rashid [1 ]
Alshehhi, Aisha [1 ]
Kang, Yoo Jung [3 ]
Al Raeesi, Dana [4 ]
Khamis, Amar H. [2 ]
Jamal, Mohamed [1 ]
Kim, Hyeon-Cheol [3 ]
机构
[1] Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai, U Arab Emirates
[2] Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Biostat Dept, Dubai, U Arab Emirates
[3] Pusan Natl Univ, Sch Dent, Dent Res Inst, Dept Conservat Dent, Yangsan, South Korea
[4] Emirates Hlth Serv Estab, Endodont Dept, Dubai, U Arab Emirates
关键词
Autoclave sterilization; cyclic fatigue; dynamic fatigue tests; fracture resistance; heat treatment; nickel-titanium; CYCLIC FATIGUE RESISTANCE; MECHANICAL-PROPERTIES; TRANSFORMATION BEHAVIOR; TORSIONAL PROPERTIES; ROTATIONAL SPEED; SHAPE-MEMORY; INSTRUMENTS; IMMERSION; STRESS;
D O I
10.1016/j.joen.2022.08.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to evaluate the dynamic cyclic fatigue resistance of heattreated nickel-titanium (NiTi) files after usage and autoclaving. Methods: Two heat-treated NiTi file systems with tip sizes of #25 (ie, ProTaper Gold F2 [Dentsply Sirona, Charlotte, NC] and TruNatomy Prime [Dentsply Sirona]) were selected. Files of each system were divided into 3 experimental subgroups (n 5 10). For subgroup 1, new files were tested to establish the baseline number of cycles to failure (NCF). For subgroup 2, files underwent canal instrumentation in a simulated J-shaped canal block with 35 degrees of curvature and a 16.5-mm length. The simulated canals were pre-enlarged using stainless steel files #10K and #15K. After instrumentation, the files were tested. For subgroup 3, files underwent canal instrumentation as in subgroup 2 followed by autoclave sterilization and then were tested for cyclic failure. The cyclic fatigue test was performed in dynamic pecking motion under body temperature. The time to fracture was recorded and calculated into NCF. Fracture fragment lengths were measured using a digital microcaliper. Statistical analysis was conducted using the independent t test and multifactorial analysis of variance with 95% significance. Scanning electron microscopy was used to examine the topographic characteristics after cyclic fatigue tests. Results: There were no significant differences between file systems in subgroup 1 using new files (P <.05). Although PG reduced the NCF after use, TN showed a significantly increased NCF (P <.05). However, after sterilization, TN showed a reduced NCF compared with the used one (P <.05). Conclusions: Cyclic loading by usage and heat treatment during sterilization may result in different cyclic fatigue resistance according to the geometry and alloy characteristics. (J Endod 2022;48:1428-1433.)
引用
收藏
页码:1428 / 1433
页数:6
相关论文
共 50 条
  • [1] Effect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel-Titanium Rotary Files
    El Abed, Rashid
    Al Raeesi, Dana
    Alshehhi, Aisha
    Alkhatib, Zuhair
    Khamis, Amar H.
    Jamal, Mohamed
    Kim, Hyeon-Cheol
    MATERIALS, 2023, 16 (06)
  • [2] Effect of sterilization on torsional fracture resistance of nickel-titanium rotary files
    Kiss, EP
    Murchison, DF
    Davis, BD
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 547 - 547
  • [3] Effect from usage and autoclave sterilization on torsional fracture resistance of heat-treated nickel-titanium instruments: an in-vitro study
    Kang, Yoo Jung
    Alshehhi, Aisha
    Al Raeesi, Dana
    Alkhatib, Zuhair
    Jamal, Mohamed
    El Abed, Rashid
    Kim, Hyeon-Cheol
    FRONTIERS IN MATERIALS, 2023, 10
  • [4] Effect of reciprocation usage of nickel-titanium rotary files on the cyclic fatigue resistance
    Lee, WooCheol
    Hwang, You-Jeong
    You, Sung-Yeop
    Kim, Hyeon-Cheol
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 146 - 150
  • [5] Effect From Surface Treatment of Nickel-Titanium Rotary Files on the Fracture Resistance
    Kim, Bo Hoon
    Ha, Jung-Hong
    Lee, Woo Cheol
    Kwak, Sang-Won
    Kim, Hyeon-Cheol
    SCANNING, 2015, 37 (01) : 82 - 87
  • [6] Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03): : 343 - 347
  • [7] Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    Silvaggio, J
    Hicks, ML
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 731 - 734
  • [8] Multiple autoclave cycles affect the surface of rotary nickel-titanium files: An atomic force microscopy study
    Valois, Caroline R. A.
    Silva, Luciano P.
    Azevedo, Ricardo B.
    JOURNAL OF ENDODONTICS, 2008, 34 (07) : 859 - 862
  • [9] Defects in rotary nickel-titanium files after clinical use
    Sattapan, B
    Nervo, GJ
    Palamara, JEA
    Messer, HH
    JOURNAL OF ENDODONTICS, 2000, 26 (03) : 161 - 165
  • [10] A method to assess rotary nickel-titanium files
    Svec, TA
    Powers, JM
    JOURNAL OF ENDODONTICS, 2000, 26 (09) : 517 - 518