Effect from usage and autoclave sterilization on torsional fracture resistance of heat-treated nickel-titanium instruments: an in-vitro study

被引:1
|
作者
Kang, Yoo Jung [1 ]
Alshehhi, Aisha [2 ]
Al Raeesi, Dana [3 ]
Alkhatib, Zuhair [2 ,4 ]
Jamal, Mohamed [2 ]
El Abed, Rashid [2 ]
Kim, Hyeon-Cheol [1 ]
机构
[1] Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Conservat Dent, Yangsan, South Korea
[2] Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai, U Arab Emirates
[3] Emirates Hlth Serv Estab, Endodont Dept, Dubai, U Arab Emirates
[4] Emirates Endodont Soc, Dubai, U Arab Emirates
关键词
fracture resistance; heat treatment; nickel-titanium files; torsional fracture; usage; sterilization; MECHANICAL-PROPERTIES; CYCLIC FATIGUE; STAINLESS-STEEL; CURRENT CHALLENGES; SHAPE-MEMORY; ROTARY; FILES; BEHAVIOR;
D O I
10.3389/fmats.2023.1215780
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aimed to evaluate the effect from usage and autoclaving on torsional fracture resistance of heat-treated nickel-titanium rotary instruments. ProTaper Gold F2 (PG) and TruNatomy Prime (TN) were selected. For group-N, new files were tested to make a baseline torsional resistance. For group-U, files underwent instrumentation in a J-shaped canal block, and files were tested. For group-S, files underwent instrumentation as in the group-U and followed by autoclave sterilization then were tested. Maximum torsional strength and distortion angel until fracture were measured using a customized device and toughness was calculated. Statistical analysis was conducted at the significance level of 95%. The topographic appearances of torsional fracture fragments were examined under scanning electron microscopy. PG showed significantly higher torsional strength after usage and sterilization; however, TN had reduced torsional strength (p < 0.05). PG showed significantly higher torsional strength in group-S than subgroup-N, while TN showed significantly lower torsional strength in group-U than group-N (p < 0.05). Regardless of the test conditions, PG showed significantly higher torsional strength and toughness than TN while TN had bigger distortion angle than PG (p < 0.05). The mechanical loads from usage and heat application during sterilization may result in alteration of torsional resistances according to geometry and alloy characteristics.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    Silvaggio, J
    Hicks, ML
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 731 - 734
  • [22] Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use
    Kamali, S. G.
    Turkaydin, D.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (02) : 247 - 253
  • [23] Evaluation of cyclic fatigue resistance of four heat-treated nickel-titanium single file systems in canals with single curvature - An in-vitro study
    Altufayli, Mohammad Daher
    Salem, Basem
    Katbeh, Imad
    Georges, Pierre
    Moualla, Roua Kamel
    MEDICAL SCIENCE, 2021, 25 (115) : 2275 - 2280
  • [24] Torsional Resistance of Two New Heat Treated Nickel Titanium Rotary Instruments: An in Vitro Evaluation
    Gambarini, Gianluca
    Miccoli, Gabriele
    Di Nardo, Dario
    Del Giudice, Andrea
    Mazzoni, Alessandro
    Seracchiani, Marco
    Testarelli, Luca
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2020, 20 : 1 - 7
  • [25] Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments
    Alfawaz, Hussam
    Alqedairi, Abdullah
    Alsharekh, Hala
    Almuzaini, Eman
    Alzahrani, Shand
    Jamleh, Ahmed
    JOURNAL OF ENDODONTICS, 2018, 44 (10) : 1563 - 1566
  • [26] The Effect of Multiple Autoclave Sterilization on the Cyclic Fatigue of Three Heat-Treated Nickel-Titanium Rotary Files: EdgeFile X7, Vortex Blue, and TRUShape
    Sharroufna, Reham
    Mashyakhy, Mohammed
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [27] Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study
    Greco, Katia
    Paolone, Gaetano
    Cicero, Giuseppe
    Tete, Giulia
    Cantile, Nicola
    Sberna, Maria Teresa
    Saladino, Teresa
    Gherlone, Enrico Felice
    Cantatore, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (19)
  • [28] Fracture resistances of heat-treated nickel-titanium files used for minimally invasive instrumentation
    Kang, Yoo Jung
    Kwak, Sang Won
    Ha, Jung-Hong
    Gambarini, Gianluca
    Kim, Hyeon-Cheol
    BMC ORAL HEALTH, 2025, 25 (01):
  • [29] Cutting efficiency of conventional and heat-treated nickel-titanium rotary or reciprocating glide path instruments
    Pedulla, E.
    Leanza, G.
    La Rosa, G. R. M.
    Gueli, A. M.
    Pasquale, S.
    Plotino, G.
    Rapisarda, E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (03) : 376 - 384
  • [30] Torsional fatigue resistance of pathfinding instruments manufactured from several nickel-titanium alloys
    Alcalde, M. P.
    Duarte, M. A. H.
    Bramante, C. M.
    Tanomaru-filho, M.
    Vasconcelos, B. C.
    So, M. V. R.
    Vivan, R. R.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (06) : 697 - 704