Morphometric Analysis and Linear Measurements of the Scala Tympani and Implications in Cochlear Implant Electrodes

被引:5
|
作者
Fujiwara, Rance J. T. [1 ]
Ishiyama, Gail [2 ]
Lopez, Ivan A. [1 ]
Ishiyama, Akira [1 ,3 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Neurol, Los Angeles, CA USA
[3] 10833 Conte Ave,62-132 CHS, Los Angeles, CA 90095 USA
关键词
3-D reconstruction; Cochlear implant; Electrode design; Scala tympani; Temporal bone; TISSUE FORMATION; FIBROUS TISSUE; DIMENSIONS; BONE; INTRACOCHLEAR; RECOGNITION;
D O I
10.1097/MAO.0000000000003848
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
HypothesisThe objective of this study was to perform detailed height and cross-sectional area measurements of the scala tympani in histologic sections of nondiseased human temporal bones and correlate them with cochlear implant electrode dimensions.BackgroundPrevious investigations in scala tympani dimensions have used microcomputed tomography or casting modalities, which cannot be correlated directly with microanatomy visible on histologic specimens.MethodsThree-dimensional reconstructions of 10 archival human temporal bone specimens with no history of middle or inner ear disease were generated using hematoxylin and eosin histopathologic slides. At 90-degree intervals, the heights of the scala tympani at lateral wall, midscala, and perimodiolar locations were measured, along with cross-sectional area.ResultsThe vertical height of the scala tympani at its lateral wall significantly decreased from 1.28 to 0.88 mm from 0 to 180 degrees, and the perimodiolar height decreased from 1.20 to 0.85 mm. The cross-sectional area decreased from 2.29 (standard deviation, 0.60) mm(2) to 1.38 (standard deviation, 0.13) mm(2) from 0 to 180 degrees (p = 0.001). After 360 degrees, the scala tympani shape transitioned from an ovoid to triangular shape, corresponding with a significantly decreased lateral height relative to perimodiolar height. Wide variability was observed among the cochlear implant electrode sizes relative to scala tympani measurements.ConclusionThe present study is the first to conduct detailed measurements of heights and cross-sectional area of the scala tympani and the first to statistically characterize the change in its shape after the basal turn. These measurements have important implications in understanding locations of intracochlear trauma during insertion and electrode design.
引用
收藏
页码:E343 / E349
页数:7
相关论文
共 42 条
  • [31] Morphometric Measurements of the Incomplete Partition Type II (IP-II) Cochlea and Implications on Cochlear Implantation
    Xiao, Adam Y.
    Saad, Miryam
    Fujiwara, Rance J. T.
    Wong, Emily C.
    Korte, Grant O.
    Sennaroglu, Levent
    Lopez, Ivan A.
    Ishiyama, Gail
    Ishiyama, Akira
    OTOLOGY & NEUROTOLOGY, 2025, 46 (02) : 206 - 214
  • [32] Morphometric linear and angular measurements of the human cochlea in implant patients using 3-dimensional reconstruction
    Danielian, Arman
    Ishiyama, Gail
    Lopez, Ivan A.
    Ishiyama, Akira
    HEARING RESEARCH, 2020, 386
  • [33] Cochlear Implant Insertion Routes and Intra-operative Electrophysiological Measurements: A Retrospective Analysis at a Tertiary Care Centre
    Tadke, Kanchan
    Singh, Pradyumna
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2024, 76 (01) : 928 - 933
  • [34] Cochlear Implant Insertion Routes and Intra-operative Electrophysiological Measurements: A Retrospective Analysis at a Tertiary Care Centre
    Kanchan Tadke
    Pradyumna Singh
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2024, 76 : 928 - 933
  • [35] Effects of the LactoSorb® bioabsorbable plates on the craniofacial development of rabbits:: direct morphometric analysis using linear measurements
    Cancado, R. P.
    Cardoso, E. S.
    Bourguignon Filho, A. M.
    Borges, H. O. I.
    Heitz, C.
    de Oliveira, M. G.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (06) : 528 - 532
  • [36] Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    Sennerby, Lars
    Meredith, Neil
    PERIODONTOLOGY 2000, 2008, 47 : 51 - 66
  • [37] Independent component analysis for cochlear implant artifacts attenuation from electrically evoked auditory steady-state response measurements
    Deprez, Hanne
    Gransier, Robin
    Hofmann, Michael
    van Wieringen, Astrid
    Wouters, Jan
    Moonen, Marc
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (01)
  • [38] Linear and geometric morphometric analysis of long bone scaling patterns in jurassic neosauropod dinosaurs: Their functional and paleobiological implications
    Bonnan, Matthew F.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2007, 290 (09): : 1089 - 1111
  • [39] Effects of measurement errors on psychometric measurements in ergonomics studies: Implications for correlations, ANOVA, linear regression, factor analysis, and linear discriminant analysis
    Liu, Yan
    Salvendy, Gavriel
    ERGONOMICS, 2009, 52 (05) : 499 - 511
  • [40] Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a morse taper implant
    Iplikçioglu, H
    Akça, K
    Çehreli, MC
    Sahin, S
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (02) : 258 - 265