Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry

被引:5
|
作者
Cheng, Jing [1 ]
Zhang, Haidong [2 ,3 ,4 ,5 ]
Liu, Hailin [6 ]
Li, Junying [7 ]
Wang, Hom-Lay [8 ,10 ]
Tao, Xian [9 ,11 ]
机构
[1] Xiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
[2] Peking Univ, Sch & Hosp Stomatol, Dept Periodontol, Beijing, Peoples R China
[3] Natl Ctr Stomatol, Beijing, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[5] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[6] Jingpin Med Technol Beijing Co Ltd, Beijing, Peoples R China
[7] Univ Michigan, Dept Biol & Mat Sci & Prosthodont, Sch Dent, Ann Arbor, MI USA
[8] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[9] Stomatol Hosp, Dept Prosthodont, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen Med Coll, Xiamen, Peoples R China
[10] Univ Michigan, Dept Periodont & Oral Med, Sch Dent, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[11] Xiamen Med Coll, Stomatol Hosp, Dept Prosthodont, 1309 Lvling Rd, Xiamen 361008, Fujian, Peoples R China
关键词
accuracy; digital impression; intraoral scanning; stereophotogrammetry; MULTIPLE IMPLANTS; PART I; MISFIT; PROSTHESES; POSITIONS; SURVIVAL; IMPACT;
D O I
10.1111/clr.14252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. Materials and Methods: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. Results: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). Conclusions: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.
引用
收藏
页码:560 / 572
页数:13
相关论文
共 50 条
  • [31] In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material
    Di Fiore, Adolfo
    Meneghello, Roberto
    Savio, Gianpaolo
    Sivolella, Stefano
    Katsoulis, Joannis
    Stellini, Edoardo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E721 - E729
  • [32] Accuracy of digital and conventional implant-level impression techniques for maxillary full-arch screw-retained prosthesis: A crossover randomized trial
    Jasim, Ammar Ghanim
    Abo Elezz, Mona Galal
    Altonbary, Gilan Y.
    Elsyad, Moustafa Abdou
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (04) : 714 - 723
  • [33] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [34] COMPARISON OF THE ACCURACY OF INTRAORAL SCANNING AND CONVENTIONAL IMPRESSION TECHNIQUES ON IMPLANTS: A REVIEW
    Arcuri, L.
    Lorenzi, C.
    Vanni, A.
    Bianchi, N.
    Dolci, A.
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 89 - 97
  • [35] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454
  • [36] Does intra-oral scan improve the impression accuracy of full-arch implant-supported prostheses: A systematic review and meta-analysis
    Cai, Zheng-zhen
    Li, Xin
    Wu, Xin-Yu
    Lai, Hong-Chang
    Shi, Jun-Yu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024,
  • [37] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [38] A Comparison of Accuracy of Different Dental Restorative Materials between Intraoral Scanning and Conventional Impression-Taking: An In Vitro Study
    Lim, Jung-Hwa
    Mangal, Utkarsh
    Nam, Na-Eun
    Choi, Sung-Hwan
    Shim, June-Sung
    Kim, Jong-Eun
    MATERIALS, 2021, 14 (08)
  • [39] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    JOURNAL OF DENTISTRY, 2022, 126
  • [40] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Yonca Onbasi
    Sabrin Abu-Hossin
    Maria Paulig
    Lara Berger
    Manfred Wichmann
    Ragai-Edward Matta
    Scientific Reports, 12 (1)