3D geometric modeling of three-thread fleece fabric based on micro-CT

被引:0
|
作者
Yu, Yuelin [1 ,2 ]
Wu, Weili [1 ]
Chen, Weilai [1 ,4 ]
Shao, Yiqin [1 ]
Zhu, Chunhong [2 ]
Gu, Xuefeng [3 ]
Hu, Shengchao [1 ]
机构
[1] Zhejiang Sci Tech Univ, Fac Text Sci & Technol, Hangzhou, Peoples R China
[2] Shinshu Univ, Grad Sch Med Sci & Technol, Ueda, Nagano, Japan
[3] Ningbo Myfitt Text Technol Co Ltd, Ningbo, Peoples R China
[4] Zhejiang Sci Tech Univ, 928 Ave 2,XiashaHigher Educ Pk, Hangzhou 310018, Zhejiang, Peoples R China
关键词
Three-thread fleece fabric; 3D modeling; micro-CT; spatial structure; standard curve equation fitting; WEFT; SIMULATION; FIBER; MERCERIZATION; COMPOSITES; BEHAVIOR;
D O I
10.1177/00405175221135206
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the era of information technology, the update cycle of textiles is shortened, which urgently demands new design and higher quality. Therefore, the traditional mode of quality control after knitting faces great challenges due to the hysteresis and huge material loss. This problem can be solved by the digitization of textiles, which aims at adjusting before knitting, while a key step of digitization is geometric modeling. Herein, a three-dimensional geometric model of three-thread fleece fabric is constructed for the first time based on micro-computed tomography technology. First, the computed tomography scan data were flipped, clipped and rendered by software DragonFly Pro to observe the loop structure more clearly, annotated and probed to obtain the coordinate points of yarn center trajectory. According to those coordinate points, the spatial trajectory of each yarn was reconstructed by the spline curve method using software Catia, then the unit cell models of each group of yarns were obtained and assembled to form a complete three-dimensional loop model. Finally, the constructed geometric model was compared with the actual fabric, and standard curve equations of the loop trajectory were fitted. The meso-scale model of three-thread fleece fabric was established accurately which clearly reflected the relationship of geometry position between yarns, providing a precise geometric model for further study on the simulation and performance prediction of knitted fabrics in future work.
引用
收藏
页码:1928 / 1937
页数:10
相关论文
共 50 条
  • [41] Micro-CT characterization on porosity structure of 3D Cf/SiCm composite
    Feng, Yanjian
    Feng, Zude
    Li, Siwei
    Zhang, Weihua
    Luan, Xingan
    Liu, Yongsheng
    Cheng, Laifei
    Zhang, Litong
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2011, 42 (11) : 1645 - 1650
  • [42] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A. C.
    Perez Edo, L.
    Marinoso, M.
    Blanche, J.
    Carbonell, J.
    Wehrli, F. W.
    BONE, 2007, 40 (06) : S259 - S260
  • [43] Small Airways Of Human Peripheral Lung Visualized In 3d By Micro-CT
    Seal, K.
    Scott, A.
    Keyes, S.
    Grinev, D.
    Sinclair, I.
    Lackie, P.
    Warner, J. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [44] 3D micro-CT images of ossicles destroyed by middle ear cholesteatoma
    Park, K
    Moon, SK
    Cho, MJ
    Won, YY
    Baek, MG
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) : 403 - 407
  • [45] Fast and accurate lacunarity calculation for large 3D micro-CT datasets
    Sebok, Daniel
    Vasarhelyi, Livia
    Szenti, Imre
    Vajtai, Robert
    Konya, Zoltan
    Kukovecz, Akos
    ACTA MATERIALIA, 2021, 214
  • [46] Extraction and analysis of large vascular networks in 3D micro-CT images
    Wan, SY
    Ritman, EL
    Higgins, WE
    MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 322 - 334
  • [47] The use of micro-CT in the investigation of a case involving 3D printed firearms
    Goia, Sofia
    Cooper, Gareth
    Norman, Danielle G.
    Primeau, Charlotte
    Hall, Michael
    Hawley, Julian
    Williams, Mark A.
    FORENSIC SCIENCE INTERNATIONAL, 2024, 363
  • [48] 3D Observation of Expansion of Stent and Elastic Recoil using Micro-CT
    Mori, Futoshi
    Nakayama, Toshio
    Matsuzawa, Teruo
    Ohta, Makoto
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 235 - +
  • [49] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanch, J.
    Marinoso, M.
    Ciria, M.
    Rotes, D.
    Carbonell, J.
    Wehrli, F.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S161 - S161
  • [50] 3D visualization of the microstructure of Quedius beesoni Cameron using micro-CT
    Zhang, Kai
    Li, De-e
    Zhu, Peiping
    Yuan, Qingxi
    Huang, Wanxia
    Liu, Xiaosong
    Hong, Youli
    Gao, Gun
    Ge, Xin
    Zhou, Hongzhang
    Wu, Ziyu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) : 2143 - 2148