3D geometric modeling of three-thread fleece fabric based on micro-CT

被引:0
|
作者
Yu, Yuelin [1 ,2 ]
Wu, Weili [1 ]
Chen, Weilai [1 ,4 ]
Shao, Yiqin [1 ]
Zhu, Chunhong [2 ]
Gu, Xuefeng [3 ]
Hu, Shengchao [1 ]
机构
[1] Zhejiang Sci Tech Univ, Fac Text Sci & Technol, Hangzhou, Peoples R China
[2] Shinshu Univ, Grad Sch Med Sci & Technol, Ueda, Nagano, Japan
[3] Ningbo Myfitt Text Technol Co Ltd, Ningbo, Peoples R China
[4] Zhejiang Sci Tech Univ, 928 Ave 2,XiashaHigher Educ Pk, Hangzhou 310018, Zhejiang, Peoples R China
关键词
Three-thread fleece fabric; 3D modeling; micro-CT; spatial structure; standard curve equation fitting; WEFT; SIMULATION; FIBER; MERCERIZATION; COMPOSITES; BEHAVIOR;
D O I
10.1177/00405175221135206
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the era of information technology, the update cycle of textiles is shortened, which urgently demands new design and higher quality. Therefore, the traditional mode of quality control after knitting faces great challenges due to the hysteresis and huge material loss. This problem can be solved by the digitization of textiles, which aims at adjusting before knitting, while a key step of digitization is geometric modeling. Herein, a three-dimensional geometric model of three-thread fleece fabric is constructed for the first time based on micro-computed tomography technology. First, the computed tomography scan data were flipped, clipped and rendered by software DragonFly Pro to observe the loop structure more clearly, annotated and probed to obtain the coordinate points of yarn center trajectory. According to those coordinate points, the spatial trajectory of each yarn was reconstructed by the spline curve method using software Catia, then the unit cell models of each group of yarns were obtained and assembled to form a complete three-dimensional loop model. Finally, the constructed geometric model was compared with the actual fabric, and standard curve equations of the loop trajectory were fitted. The meso-scale model of three-thread fleece fabric was established accurately which clearly reflected the relationship of geometry position between yarns, providing a precise geometric model for further study on the simulation and performance prediction of knitted fabrics in future work.
引用
收藏
页码:1928 / 1937
页数:10
相关论文
共 50 条
  • [21] Research on Cotton Yarn Based on Synchrotron Radiation 3D Micro-CT Imaging
    Shuaikang Han
    Qianhe Li
    Md All Amin Newton
    Yantao Gao
    Binjie Xin
    Ke Li
    Fibers and Polymers, 2024, 25 : 543 - 555
  • [22] Research on Cotton Yarn Based on Synchrotron Radiation 3D Micro-CT Imaging
    Han, Shuaikang
    Li, Qianhe
    Newton, Md All Amin
    Gao, Yantao
    Xin, Binjie
    Li, Ke
    FIBERS AND POLYMERS, 2024, 25 (02) : 543 - 555
  • [23] In Vivo Biological Evaluation of Micro-CT Based 3D Conformal Radiotherapy System
    Nelson, G.
    Rodriguez, M.
    Zhou, H.
    Lee, A.
    Wu, J.
    Tran, P.
    Felsher, D.
    Keall, P.
    Graves, E.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [24] Quantitative arterial tree morphometry using 3D Micro-CT
    Johnson, RH
    Molthen, RC
    Hanger, CC
    Haworth, ST
    Dawson, CA
    Linehan, JH
    RADIOLOGY, 1998, 209P : 400 - 400
  • [25] Automatic segmentation of 3D micro-CT coronary vascular images
    Lee, Jack
    Beighley, Patricia
    Ritman, Erik
    Smith, Nicolas
    MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 630 - 647
  • [26] Micro-CT analysis of 3D printed provisional crowns fitting
    Alsubaiy, Ebrahim Fihaid
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 259 - 268
  • [27] Micro-CT as a novel technique for 3D reconstruction of molluscan anatomy
    Golding, Rosemary E.
    Jones, Allan S.
    MOLLUSCAN RESEARCH, 2007, 27 (03) : 123 - 128
  • [28] 3D imaging of lung tissue by confocal microscopy and micro-CT
    Kriete, A
    Breithecker, A
    Rau, W
    LASER-TISSUE INTERACTION XII: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2001, 4257 : 469 - 476
  • [29] Investigation on the validity of 3D micro-CT imaging in the fish brain
    Udagawa, Shingo
    Miyara, Keitaro
    Takekata, Hiroki
    Takeuchi, Yuki
    Takemura, Akihiro
    JOURNAL OF NEUROSCIENCE METHODS, 2019, 328
  • [30] Development of the 3D volumetric micro-CT scanner for preclinical animals
    Kim, Kyong-Woo
    Kim, Kyu-Gyeom
    Kim, Jae-Hee
    Min, Jong-Hwan
    Lee, Hee-Sin
    Lee, Joon-Whoan
    3D RESEARCH, 2011, 2 (02) : 1 - 6