3D geometric modeling of three-thread fleece fabric based on micro-CT

被引:0
|
作者
Yu, Yuelin [1 ,2 ]
Wu, Weili [1 ]
Chen, Weilai [1 ,4 ]
Shao, Yiqin [1 ]
Zhu, Chunhong [2 ]
Gu, Xuefeng [3 ]
Hu, Shengchao [1 ]
机构
[1] Zhejiang Sci Tech Univ, Fac Text Sci & Technol, Hangzhou, Peoples R China
[2] Shinshu Univ, Grad Sch Med Sci & Technol, Ueda, Nagano, Japan
[3] Ningbo Myfitt Text Technol Co Ltd, Ningbo, Peoples R China
[4] Zhejiang Sci Tech Univ, 928 Ave 2,XiashaHigher Educ Pk, Hangzhou 310018, Zhejiang, Peoples R China
关键词
Three-thread fleece fabric; 3D modeling; micro-CT; spatial structure; standard curve equation fitting; WEFT; SIMULATION; FIBER; MERCERIZATION; COMPOSITES; BEHAVIOR;
D O I
10.1177/00405175221135206
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
In the era of information technology, the update cycle of textiles is shortened, which urgently demands new design and higher quality. Therefore, the traditional mode of quality control after knitting faces great challenges due to the hysteresis and huge material loss. This problem can be solved by the digitization of textiles, which aims at adjusting before knitting, while a key step of digitization is geometric modeling. Herein, a three-dimensional geometric model of three-thread fleece fabric is constructed for the first time based on micro-computed tomography technology. First, the computed tomography scan data were flipped, clipped and rendered by software DragonFly Pro to observe the loop structure more clearly, annotated and probed to obtain the coordinate points of yarn center trajectory. According to those coordinate points, the spatial trajectory of each yarn was reconstructed by the spline curve method using software Catia, then the unit cell models of each group of yarns were obtained and assembled to form a complete three-dimensional loop model. Finally, the constructed geometric model was compared with the actual fabric, and standard curve equations of the loop trajectory were fitted. The meso-scale model of three-thread fleece fabric was established accurately which clearly reflected the relationship of geometry position between yarns, providing a precise geometric model for further study on the simulation and performance prediction of knitted fabrics in future work.
引用
收藏
页码:1928 / 1937
页数:10
相关论文
共 50 条
  • [1] Fibrous Impact on Several Primary Characteristics of Three-Thread Fleece Fabric
    Farha, Farial Islam
    Smriti, Shamima Akter
    Sarker, Md Aswad Al Haque
    Xu, Fujun
    AATCC JOURNAL OF RESEARCH, 2019, 6 (05) : 30 - 38
  • [2] Evaluation of physical and mechanical characteristics of three-thread fleece knit fabric for their structural changes
    Kaikobad, Md.
    Mahmud, Md. Faisal
    Sayam, Abdullah
    Paul, Suman Chandra
    Reza, Md. Musa Ali
    Faruque, Md. Omar
    Apel, Nazmul Alam
    Sarker, Md. Emdad
    HELIYON, 2023, 9 (11)
  • [3] Improvement of Elastic Property of Circular Weft Knit Three-Thread Fleece Fabric by Changing Stitch Length
    Hossain, Md Shakhawat
    Alimuzzaman, Shah
    Haque, Abu Naser Md Ahsanul
    AATCC JOURNAL OF RESEARCH, 2021, 8 (01) : 25 - 32
  • [4] 3D micro-CT for functional genomics
    Johnson, RH
    Molthen, RM
    Hanger, CC
    Karau, KL
    Haworth, ST
    Dawson, CA
    RADIOLOGY, 1999, 213P : 194 - 194
  • [5] A novel 3D mouse embryo atlas based on micro-CT
    Wong, Michael D.
    Dorr, Adrienne E.
    Walls, Johnathon R.
    Lerch, Jason P.
    Henkelman, R. Mark
    DEVELOPMENT, 2012, 139 (17): : 3248 - 3256
  • [6] The Role of Micro-CT in 3D Histology Imaging
    Senter-Zapata, Michael
    Patel, Kunal
    Bautista, Pinky A.
    Griffin, Molly
    Michaelson, James
    Yagi, Yukako
    PATHOBIOLOGY, 2016, 83 (2-3) : 140 - 147
  • [7] 3D micro-CT imaging of the postmortem brain
    de Crespigny, Alex
    Bou-Reslan, Hani
    Nishimura, Merry C.
    Phillips, Heidi
    Carano, Richard A. D.
    D'Arceuil, Helen E.
    JOURNAL OF NEUROSCIENCE METHODS, 2008, 171 (02) : 207 - 213
  • [8] FEA Based on 3D Micro-CT Images of Mesoporous Engineered Hydrogels
    Siad, L.
    Jing, J.
    Braux, J.
    Dubus, M.
    Velard, F.
    Laurent-Maquin, D.
    Gangloff, S. C.
    Kerdjoudj, H.
    Rahouadj, R.
    Schmidt, J. -F.
    Ganghoffer, J. -F.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2015, 5 (06) : 885 - 890
  • [9] Reconstruction of the 3D Geometry of the Ossicular Chain Based on Micro-CT Imaging
    Kwacz, Monika
    Wysocki, Jaroslaw
    Krakowian, Piotr
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2012, 32 (01) : 27 - 40
  • [10] Evaluation of a Micro-CT Based 3D Conformal Animal Radiotherapy System
    Zhou, H.
    Xu, J.
    Rodriguez, M.
    van den Haak, F.
    Zhu, X.
    Xian, Y.
    Nelson, G.
    Jogani, R.
    Keall, P.
    Graves, E.
    MEDICAL PHYSICS, 2009, 36 (06) : 2800 - +