Study of the flexural performance and a novel calculation formula for the degree of composite action for precast concrete sandwich panels

被引:4
|
作者
Zheng, Tiancai [1 ]
Ge, Qi [1 ,3 ]
Xiong, Feng [1 ]
Li, Guo [2 ]
Xue, Yu [2 ]
Deng, Xiang [2 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, MOE Key Lab Deep Earth Sci & Engn, Chengdu, Peoples R China
[2] China Construct Third Bur First Engn CO LTD, Wuhan, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, 24 South Sect 1,Yihuan Rd, Chengdu 610065, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
degree of composite action; displacement method; flexural performance; neutral axis method; precast concrete sandwich panels; strain method; BEHAVIOR;
D O I
10.1002/tal.2065
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the flexural performance and degree of composite action (DCA) of precast concrete sandwich panels (PCSPs) with four types of connectors. Five full-scale specimens were designed, and 4-point bending tests were performed. The specimens included four PCSPs utilizing glass fiber reinforced polymer (GFRP) truss connectors, steel truss connectors, concrete rib connectors, and GFRP pin connectors, respectively, along with a solid panel (SP). The results indicated that the flexural performance and DCA provided by the four types of connectors followed an ascending order as follows: GFRP pin-type connectors, GFRP truss connectors, steel truss connectors, and concrete rib-type connectors. Moreover, the study presented a novel method for calculating DCA, namely, the neutral axis method, which was compared with the displacement and strain methods. The reasonableness and accuracy of the neutral axis method in calculating DCA during the linear elastic stage were verified. Results indicated that the neutral axis method provided more precise and reasonable DCA that closely matched the experimental results compared with the displacement and strain methods. Additionally, the neutral axis method was simpler to calculate DCA and had a broader range of applications. Finally, the study provided recommendations for the optimal application scenarios of each calculation method.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Study on the Composite Performance of Sandwich Wall Panels with SGCCs
    Jiang, Huanzhi
    Xie, Libo
    Chang, Fengyuan
    Cao, Yu
    Guo, Zhengxing
    BUILDINGS, 2025, 15 (01)
  • [42] Data-driven prediction method for flexural performance of ECC composite sandwich panels
    Xiong, Feng
    Bian, Yu
    Liu, Ye
    Ge, Qi
    Deng, Chubing
    STRUCTURES, 2024, 70
  • [43] Experimental and numerical study on the shear performance of stainless steel-GFRP connectors for use in precast concrete sandwich panels
    Zhao, Boyi
    Du, Lingfeng
    Chen, Guixiang
    Yue, Longfei
    Cui, Chenxing
    Ge, Mengmeng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [44] Composite action of structural steel beams and precast concrete slabs for the flexural strength limit state
    Uy, B.
    Bradford, M.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2006, 7 (02) : 123 - 133
  • [45] Experimental study on the flexural behavior of insulated concrete sandwich panels with wires as shear connectors
    Joseph, J. Daniel Ronald
    Prabakar, J.
    Alagusundaramoorthy, P.
    ALEXANDRIA ENGINEERING JOURNAL, 2019, 58 (03) : 901 - 908
  • [46] Performance-based framework for evaluating the flexural response of precast concrete wall panels to blast loading
    Gombeda, Matthew J.
    Naito, Clay J.
    Quiel, Spencer E.
    ENGINEERING STRUCTURES, 2018, 168 : 473 - 486
  • [47] Structural Performance of Precast Concrete Sandwich Panels Made with FRP Vierendeel Truss-Like Connectors
    Hamed, Ehab
    Negru, Daniel
    Yalda, Richard
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (03)
  • [48] RETRACTED: Thermal performance of super-insulated precast concrete structural sandwich panels (Retracted Article)
    Bida, Sani Mohammed
    Aziz, Farah Nora Aznieta Abdul
    Jaafar, Mohd Saleh
    Hejazi, Farzad
    Nabilah, Abu Bakar
    ENERGY AND BUILDINGS, 2018, 176 : 418 - 430
  • [49] Structural performance and section optimization of precast concrete sandwich panels with pin-type GFRP connectors
    Huang, Jun-Qi
    Jiang, Qing
    Chong, Xun
    Zhao, Chao-Liang
    Wang, Zi-Yang
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (11) : 2351 - 2363
  • [50] Cost optimization of load carrying thin-walled precast high performance concrete sandwich panels
    Hodicky, K.
    Hansen, S.
    Hulin, T.
    Schmidt, J. W.
    Stang, H.
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2015, 52 (06) : 1089 - 1106