Aortic Dissection From an Intra-aortic Balloon Pump: A Dangerous Complication to Keep in Mind

被引:0
|
作者
Mijares-Rojas, Ivan A. [1 ]
Trujillo, Luis G. [1 ]
Lecompte-Osorio, Paola A. [1 ]
Trevino, Enrique F. Martinez [2 ]
Munagala, Mrudula [3 ]
机构
[1] Univ Miami, Jackson Mem Hosp, Miller Sch Med, Internal Med, Miami, FL 33134 USA
[2] John H Stroger Jr Hosp Cook Cty, Internal Med, Chicago, IL USA
[3] Miami Transplant Inst, Cardiol, Miami, FL USA
关键词
intra-aortic balloon pump; aortic dissection management; mechanical circulatory assistant devices; thoracic endovascular aortic repair; thoracic aortic dissection; intra-aortic balloon pump (iabp); CARDIOGENIC-SHOCK; COUNTERPULSATION; INSERTION;
D O I
10.7759/cureus.39122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the benefits of the intra-aortic balloon pump (IABP) being a subject of debate, it remains a widely available and easy-to-use mechanical circulatory support device. Nonetheless, its use is not exempt from complications. Aortic dissection from IABP is an infrequent but deathly complication. We describe a case in which early recognition of the condition led to control through an endovascular approach. A 57-year-old male was admitted for acute decompensated heart failure requiring intravenous inotropic agents. While undergoing assessment for a heart transplant, he developed cardiogenic shock requiring initiation of mechanical circulatory support with an IABP. A few hours after device implantation, the patient developed acute tearing chest pain and was found to have an acute dissection in the descending thoracic aorta. Prompt liaison with the endovascular team led to a thoracic endovascular aortic repair to control the extent of the lesion.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A complication of an axillary intra-aortic balloon pump
    Kodack, Eileen
    Patel, Riya
    Bonner, Carain
    Pantin, Enrique
    JOURNAL OF SURGICAL CASE REPORTS, 2024, 2024 (03):
  • [2] Intra-Aortic Balloon Pump Simulating Thoracic Aortic Dissection
    Siegel, Yoel
    Munera, Felipe
    Durso, Anthony M.
    Roth, Patrick
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 630 - 631
  • [3] Undiagnosed aortic dissection in patient with intra-aortic balloon pump
    Raut, Monish S.
    Maheshwari, Arun
    Sharma, Manish
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (03) : 549 - +
  • [4] A rare complication of intra-aortic balloon pump placement
    Varadarajan, B
    Karski, J
    Vegas, A
    Heinrich, L
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (02) : 259 - 260
  • [5] Is intra-aortic balloon pump absolutely contraindicated in type A aortic dissection?
    Jaussaud, N.
    Durand, M.
    Boignard, A.
    Porcu, P.
    Hacini, R.
    Blin, D.
    Chavanon, O.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2015, 56 (04): : 513 - 518
  • [6] The Intra-Aortic Balloon Pump
    Gajanan, Ganesh
    Brilakis, Emmanouil S.
    Siller-Matula, Jolanta M.
    Zolty, Ronald L.
    Velagapudi, Poonam
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (168): : 1 - 12
  • [7] THE INTRA-AORTIC BALLOON PUMP
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1980, 281 (6243): : 764 - 764
  • [8] Aortic dissection caused by intra-aortic balloon pumping
    Alberto de Agustin, Jose
    Juan Gomez de Diego, Jose
    Javier Nunez-Gil, Ivan
    Macaya, Carlos
    Perez de Isla, Leopoldo
    EUROPEAN HEART JOURNAL, 2014, 35 (26) : 1718 - 1718
  • [9] Location of an intra-aortic balloon pump
    Fletcher, SN
    Riedel, BJCJ
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (02) : 267 - 268
  • [10] Intra-aortic Balloon Pump Securement
    Holcomb, Brandi
    CRITICAL CARE NURSE, 2022, 42 (06) : 79 - 81