Experimental and Computational Fluid Dynamic-CFD Analysis Simulation of Heat Transfer Using Graphene Nanoplatelets GNP/Water in the Double Tube Heat Exchanger

被引:4
|
作者
Lima, Carlos C. X. S. [1 ]
Ochoa, Alvaro A. V. [1 ,2 ]
da Costa, Jose A. P. [1 ,2 ]
de Menezes, Frederico D. [1 ,2 ]
Alves, Joao V. P. [2 ]
Ferreira, Julia M. G. A. [2 ]
Azevedo, Clara C. A. [1 ]
Michima, Paula S. A. [1 ]
Leite, Gustavo N. P. [1 ,2 ]
机构
[1] Univ Fed Pernambuco, Dept Mech Engn, Cidade Univ,1235, BR-50670901 Recife, Brazil
[2] Fed Inst Educ Sci & Technol Pernambuco, Dept Higher Educ Courses DACS, Av Prof Luiz Freire,500, BR-50740545 Recife, Brazil
关键词
double tube heat exchangers; heat transfer; nanofluids; graphene; NANOFLUID FLOW; PRESSURE-DROP; TRANSFER PERFORMANCE; TRANSFER ENHANCEMENT; FRICTION FACTOR; HYDRAULIC CHARACTERISTICS; WATER NANOFLUIDS; HYBRID NANOFLUID; MASS-TRANSFER; TAPE INSERTS;
D O I
10.3390/pr11092735
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study investigates and compares the experimental heat transfer performance and simulation via computational fluid dynamics (CFD) of graphene nanoplatelets (GNP) and water nanofluids GNP/water in the double-tube-type heat exchanger (DTHE). Tests were conducted with water/water and GNP/water fluids, with the nanofluid for the hot-fluid circuit and water for the cold-fluid circuit, with counterflow direction, varying the nanofluid concentrations by weight (wt%) at 0.0125%, 0.025%, and 0.050%, the operating temperature at 50 and 60 & DEG;C, and Reynolds numbers between 2000-6000. The results showed that 0.025 wt% GNP presented better thermal performance, with a 28% increase in the temperature gain. The 0.025 wt% GNP had slightly better performance for the Nusselt number (Nu), and the 0.05 wt% GNP had a slightly better thermal effectiveness. The comparison between the experimental values showed good agreement with those calculated by empirical correlations and the CFD model, with maximum and minimum relative error values of 9% and 1%, respectively, when the Petukhov equation was used.
引用
收藏
页数:27
相关论文
共 50 条
  • [21] Experimental Investigations of Heat Transfer Enhancement in a Double Tube Heat Exchanger with Rectangular Grooved
    Sunu, Putu Wijaya
    Sutarna, I. Nyoman
    Arsawan, I. Made
    ADVANCED SCIENCE LETTERS, 2017, 23 (12) : 12190 - 12193
  • [22] An experimental study on the heat transfer characteristics of a double-tube bundle heat exchanger
    Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China
    Gaojishu Tongxin, 2009, 6 (634-637):
  • [23] Numerical simulation and analysis of enhanced heat transfer in corrugated tube heat exchanger
    Jiang, Jingzhi
    Bo, Lin
    Chen, Zhengjia
    Cui, Haiting
    Zhu, Hairong
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [24] Experimental study on flow and heat transfer of non-Newtonian fluid in a corrugated double-tube heat exchanger
    Lu W.
    Miao R.
    Wu Z.
    Wu C.
    Xie W.
    Huagong Xuebao/CIESC Journal, 2022, 73 (07): : 2924 - 2932
  • [25] Heat transfer analysis of the DOT 4 brake fluid using a double pipe heat exchanger
    Sharma, C.
    Siddiqui, M.
    Imran, Md
    Manikandaraja, G.
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2020), PTS 1-6, 2020, 912
  • [26] Computational fluid dynamic analysis of graphene oxide/water nanofluid heat transfer over a double backward-facing microchannel
    Dehghan, Peymaneh
    Keramat, Fatemeh
    Mofarahi, Masoud
    Lee, Chang-Ha
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 145
  • [27] The open cycle simulation of the earth air heat exchanger using computational fluid dynamic
    Manik, T. U. H. S. G.
    Simanjuntak, J. S. C.
    Sitorus, T. B.
    1ST INTERNATIONAL CONFERENCE ON INDUSTRIAL AND MANUFACTURING ENGINEERING, 2019, 505
  • [28] CFD analysis on heat and flow characteristics of double helically coiled tube heat exchanger handling MWCNT/water nanofluids
    Kumar, P. C. Mukesh
    Chandrasekar, M.
    HELIYON, 2019, 5 (07)
  • [29] Effect of Wire Pitch on Capacity of Single Staggered Wire and Tube Heat Exchanger Using Computational Fluid Dynamic Simulation
    Akbar, F. R.
    Arsana, I. M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2020, 33 (08): : 1637 - 1642
  • [30] CFD simulation of secondary side fluid flow and heat transfer of the passive residual heat removal heat exchanger
    Ge, Jian
    Tian, Wenxi
    Qiu, Suizheng
    Su, G. H.
    NUCLEAR ENGINEERING AND DESIGN, 2018, 337 : 27 - 37