CFD analysis on heat and flow characteristics of double helically coiled tube heat exchanger handling MWCNT/water nanofluids

被引:35
|
作者
Kumar, P. C. Mukesh [1 ]
Chandrasekar, M. [2 ]
机构
[1] Univ Coll Engn, Dept Mech Engn, Dindigul 624622, Tamil Nadu, India
[2] Chettinad Coll Engn & Technol, Dept Mech Engn, Karur 639114, Tamil Nadu, India
关键词
Mechanical engineering; Nanotechnology; Computational mathematics; Volume concentration of nanoparticle; Double helically coiled tube; MWCNT /water nanofluids; Computational fluid dynamics; Pressure drop; Thermal conductivity; Nanofluid viscosity; PRESSURE-DROP; HYDRAULIC CHARACTERISTICS; TRANSFER ENHANCEMENT; FLUID; CONVECTION; SHELL; PIPE;
D O I
10.1016/j.heliyon.2019.e02030
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Double helically coiled tube heat exchangers are used in different heat transfer utilization due to higher heat transfer capabilities and with their compactness. The double helically coiled tube heat exchanger increases the turbulence and enhances the maximum heat transfer rate than the straight tubes. In this investigation, the heat transfer and pressure drop of the double helically coiled heat exchanger handling MWCNT/water nanofluids have been analyzed by the computational software ANSYS 14.5 version. The computational analysis was carried out under the laminar flow condition in the Dean number range of 1300-2200. The design of new shell and double helically coiled tube heat exchanger was done by using standard designing procedure and 3D modeling was done in Cre-O 2.0 parametric. The Finite Element Analysis software ANSYS Workbench 14.5 was used to perform CFD analysis under the standard working condition. The MWCNT/water nanofluids at 0.2%, 0.4%, and 0.6% volume concentrations have been taken for this investigation. The major factors like volume concentrations of nanofluids and Dean Number are considered for predicting the heat transfer rate and pressure drop. The simulation data was compared with the experimental data. It is studied that the heat transfer rate and pressure drop increase with increasing volume concentrations of MWCNT/water nanofluids. It is found that the Nusselt number of 0.6% MWCNT/water nanofluids is 30% higher than water at the Dean number value of 1400 and Pressure drop is 11% higher than water at the Dean number value of 2200. It is found that the simulation data hold good agreement with the experimental data. The common deviation between the Nusselt number and pressure dropof CFD data and the Nusselt number and pressure drop of experimental data are found to be 7.2% and 8.5% respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Heat transfer and friction factor analysis of MWCNT nanofluids in double helically coiled tube heat exchanger
    P. C. Mukesh Kumar
    M. Chandrasekar
    [J]. Journal of Thermal Analysis and Calorimetry, 2021, 144 : 219 - 231
  • [2] Heat transfer and friction factor analysis of MWCNT nanofluids in double helically coiled tube heat exchanger
    Mukesh Kumar, P. C.
    Chandrasekar, M.
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (01) : 219 - 231
  • [3] CFD Analysis of a Helically Coiled Tube in Tube Heat Exchanger
    Reddy, Vijaya Kumar K.
    Kumar, Sudheer Prem B.
    Gugulothu, Ravi
    Anuja, Kakaraparthi
    Rao, Viajaya P.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2017, 4 (02) : 2341 - 2349
  • [4] Heat Transfer and Fluid Flow Characteristics in Helically Coiled Tube Heat Exchanger (HCTHE) Using Nanofluids: A Review
    Narrein, K.
    Mohammed, H. A.
    [J]. JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2014, 11 (04) : 911 - 927
  • [5] A review on helically coiled tube heat exchanger using nanofluids
    Kumar, P. C. Mukesh
    Chandrasekar, M.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2020, 21 : 137 - 141
  • [6] Experimental Investigation on Heat Transfer and Pressure Drop in Double Helically Coiled Tube Heat Exchanger with MWCNT/Water Nanofluid
    Chandrasekar, M.
    Kumar, P. C. Mukesh
    [J]. JOURNAL OF APPLIED FLUID MECHANICS, 2018, 11 : 23 - 29
  • [7] PREDICTIVE ANALYSIS OF HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS IN HELICALLY COILED TUBE HEAT EXCHANGER USING REGRESSION APPROACH
    Peryiasamy Chokkiyee, Mukesh Kumar
    Balasubramanain, Rajappa
    Velusamy, Durgadevi
    [J]. THERMAL SCIENCE, 2020, 24 (01): : 505 - 513
  • [8] CFD study of heat transfer for oscillating flow in helically coiled tube heat-exchanger
    Pan, Changzhao
    Zhou, Yuan
    Wang, Junjie
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2014, 69 : 59 - 65
  • [9] Influence of nanofluids and rotation on helically coiled tube heat exchanger performance
    Narrein, K.
    Mohammed, H. A.
    [J]. THERMOCHIMICA ACTA, 2013, 564 : 13 - 23
  • [10] ANALYSIS ON THERMAL AND FLOW BEHAVIOR OF TRIPLE CONCENTRIC TUBE HEAT EXCHANGER HANDLING MWCNT-WATER NANOFLUIDS
    Periyasamy Chokkeyee, Mukesh Kumar
    Visvanathan, Hariprasath
    [J]. THERMAL SCIENCE, 2020, 24 (01): : 487 - 494