CFD analysis on heat and flow characteristics of double helically coiled tube heat exchanger handling MWCNT/water nanofluids

被引:35
|
作者
Kumar, P. C. Mukesh [1 ]
Chandrasekar, M. [2 ]
机构
[1] Univ Coll Engn, Dept Mech Engn, Dindigul 624622, Tamil Nadu, India
[2] Chettinad Coll Engn & Technol, Dept Mech Engn, Karur 639114, Tamil Nadu, India
关键词
Mechanical engineering; Nanotechnology; Computational mathematics; Volume concentration of nanoparticle; Double helically coiled tube; MWCNT /water nanofluids; Computational fluid dynamics; Pressure drop; Thermal conductivity; Nanofluid viscosity; PRESSURE-DROP; HYDRAULIC CHARACTERISTICS; TRANSFER ENHANCEMENT; FLUID; CONVECTION; SHELL; PIPE;
D O I
10.1016/j.heliyon.2019.e02030
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Double helically coiled tube heat exchangers are used in different heat transfer utilization due to higher heat transfer capabilities and with their compactness. The double helically coiled tube heat exchanger increases the turbulence and enhances the maximum heat transfer rate than the straight tubes. In this investigation, the heat transfer and pressure drop of the double helically coiled heat exchanger handling MWCNT/water nanofluids have been analyzed by the computational software ANSYS 14.5 version. The computational analysis was carried out under the laminar flow condition in the Dean number range of 1300-2200. The design of new shell and double helically coiled tube heat exchanger was done by using standard designing procedure and 3D modeling was done in Cre-O 2.0 parametric. The Finite Element Analysis software ANSYS Workbench 14.5 was used to perform CFD analysis under the standard working condition. The MWCNT/water nanofluids at 0.2%, 0.4%, and 0.6% volume concentrations have been taken for this investigation. The major factors like volume concentrations of nanofluids and Dean Number are considered for predicting the heat transfer rate and pressure drop. The simulation data was compared with the experimental data. It is studied that the heat transfer rate and pressure drop increase with increasing volume concentrations of MWCNT/water nanofluids. It is found that the Nusselt number of 0.6% MWCNT/water nanofluids is 30% higher than water at the Dean number value of 1400 and Pressure drop is 11% higher than water at the Dean number value of 2200. It is found that the simulation data hold good agreement with the experimental data. The common deviation between the Nusselt number and pressure dropof CFD data and the Nusselt number and pressure drop of experimental data are found to be 7.2% and 8.5% respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Heat transfer and performance analysis of nanofluid flow in helically coiled tube heat exchangers
    Bahrehmand, S.
    Abbassi, A.
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 109 : 628 - 637
  • [32] Heat transfer and thermodynamic analyses of a helically coiled heat exchanger using different types of nanofluids
    Khairul, M. A.
    Saidur, R.
    Rahman, M. M.
    Alim, M. A.
    Hossain, A.
    Abdin, Z.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 67 : 398 - 403
  • [33] Single-phase flow heat transfer characteristics in helically coiled tube heat exchangers
    Akgul, Dogan
    Kirkar, Safak Metin
    Onal, Busra Selenay
    Celen, Ali
    Dalkilic, Ahmet Selim
    Wongwises, Somchai
    [J]. KERNTECHNIK, 2022, 87 (01) : 1 - 25
  • [34] Heat transfer characteristics of silver/water nanofluids in a shell and tube heat exchanger
    Godson, L.
    Deepak, K.
    Enoch, C.
    Jefferson, B.
    Raja, B.
    [J]. ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2014, 14 (03) : 489 - 496
  • [35] Heat transfer characteristics of silver/water nanofluids in a shell and tube heat exchanger
    L. Godson
    K. Deepak
    C. Enoch
    B. Jefferson
    B. Raja
    [J]. Archives of Civil and Mechanical Engineering, 2014, 14 : 489 - 496
  • [36] Comparison of heat transfer characteristics of a heat exchanger with straight helical tube and a heat exchanger with coiled flow reverser
    Kazemi-Esfe, Hossein
    Shekhari, Younes
    Omidvar, Pourya
    [J]. APPLIED THERMAL ENGINEERING, 2024, 253
  • [37] Heat transfer and entropy generation analyses of nanofluids in helically coiled tube-in-tube heat exchangers
    Huminic, Gabriela
    Huminic, Angel
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 71 : 118 - 125
  • [38] Numerical Analysis of Heat Transfer on the Shell Side of a Helically Coiled Tube Heat Exchanger for Helium Applications
    Filip, Radomir
    Melichar, Tomas
    [J]. JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2021, 7 (02):
  • [39] Experimental and numerical analysis of heat transfer in the helically coiled heat exchanger
    Sobota, Tomasz
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2020, 30 (06) : 2935 - 2951
  • [40] Prediction of heat transfer performance of CuO/water nanofluids flow in spirally corrugated helically coiled heat exchanger using fuzzy logic technique
    Khairul, M. A.
    Hossain, A.
    Saidur, R.
    Alim, M. A.