Mass ratio factor in control performance of optimum tuned liquid dampers

被引:1
|
作者
Ocak, Ayla [1 ]
Bekdas, Gebrail [1 ]
Nigdeli, Sinan Melih [1 ,2 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Civil Engn, Istanbul, Turkiye
[2] Istanbul Univ Cerrahpasa, Dept Civil Engn, TR-34320 Istanbul, Turkiye
来源
关键词
damping; Jaya algorithm; mass ratio; optimization; structural control; Tuned liquid damper (TLD); SEISMIC VIBRATION CONTROL; COLUMN DAMPER; RESPONSE CONTROL; OPTIMAL-DESIGN; MOTION; SYSTEM;
D O I
10.1002/tal.2063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned liquid dampers provide structure control with the help of the liquid mass in tanks that are attached to the structure. The mass ratio affects the optimum tuned liquid damper (TLD) parameters. This study examines the effect of mass ratio on the control performance of TLD devices in providing seismic control of structures with different damping ratios. For this purpose, TLD devices with different mass ratios were placed on two different single-story steel and reinforced concrete structure models, and their performance under earthquake excitation was investigated. TLD parameters for obtaining the optimum displacement level in the 0.5- and 1.0-s structure natural period for both structure types were optimized with the Jaya algorithm (JA), which is a metaheuristic algorithm. By using the optimum TLD parameters, the structural displacement and total acceleration values were obtained by the critical earthquake analysis. When the results are examined, it is understood that TLD mass increase from a 20% mass ratio for both structure types and selected structure periods does not have a significant effect on TLD control performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Advanced seismic retrofitting with high-mass-ratio Tuned Mass Dampers
    Marrazzo, Pasquale Roberto
    Montuori, Rosario
    Nastri, Elide
    Benzoni, Gianmario
    Soil Dynamics and Earthquake Engineering, 2024, 179
  • [32] Optimum design and layout of multiple tuned mass dampers for seismic damage control of steel frame buildings
    Khatibinia, Mohsen
    Gharehbaghi, Sadjad
    Yazdani, Hessam
    Akbari, Sadegh
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [33] Optimum design of a sliding mode control for seismic mitigation of structures equipped with active tuned mass dampers
    Eliasi, Hussein
    Yazdani, Hessam
    Khatibinia, Mohsen
    Mahmoudi, Mehdi
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 81 (05) : 633 - 645
  • [34] Advanced seismic retrofitting with high-mass-ratio Tuned Mass Dampers
    Marrazzo, Pasquale Roberto
    Montuori, Rosario
    Nastri, Elide
    Benzoni, Gianmario
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 179
  • [35] Optimum Seismic Response Control of Multiple Degree of Freedom Structures using Tuned Viscous Mass Dampers
    Ikago, K.
    Sugimura, Y.
    Saito, K.
    Inoue, N.
    PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON COMPUTATIONAL STRUCTURES TECHNOLOGY, 2010, 93
  • [36] VIBRATION CONTROL EFFECTIVENESS OF PASSIVE TUNED MASS DAMPERS
    LIN, CC
    HU, CM
    WANG, JF
    HU, RY
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1994, 17 (03) : 367 - 376
  • [37] STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS
    ABDELROHMAN, M
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1981, 107 (05): : 990 - 990
  • [38] STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS
    Chang, James C.H.
    Soong, Tsu T.
    1980, 106 (06): : 1091 - 1098
  • [39] PERFORMANCE OF TUNED MASS DAMPERS UNDER WIND LOADS
    KWOK, KCS
    SAMALI, B
    ENGINEERING STRUCTURES, 1995, 17 (09) : 655 - 667
  • [40] Combined Tuned Mass Dampers for structural vibration control
    Cao, Huong Quoc
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2023, 157